MSA Britain Ltd v Revenue & Customs (CUSTOMS DUTY : Classification - nomenclature) [2019] UKFTT 693 (TC) (13 November 2019)
The Altair portable gas detectors have as a main function the analysis and display of the composition of ambient gases, not merely alerting. This analysis function brings them within heading 9027 of the Combined Nomenclature. The devices are not properly classifiable under heading 9026 (measurement of gas level) or heading 8531 (alarms), as 9027 is more specific and prevails by application of the Section and Chapter Notes and the General Interpretative Rules. The reasoning in Commission Implementing Regulation 2018/1208 applies by analogy, supporting classification under 9027.
- Citation
- [2019] UKFTT 693
- Parties
- Appellant: MSA Britain Ltd; Respondents: The Commissioners for Her Majesty’s Revenue & Customs
- Jurisdiction
- United Kingdom
- Judgment Date
- 13 November 2019
- Procedural Posture
- Customs Duty Classification Appeal / First Tier Tribunal (tax Chamber) Decision
- Outcome
- Appeal dismissed
- Legal Topics
- Customs Classification, Combined Nomenclature, Binding Tariff Information, Interpretation of Tariff Headings
Case Brief
Summary, issues, holding and outcome
More case intelligence is available
Unlock the full research layer for this judgment.
Parties
MSA Britain Ltd
Appellant
The Commissioners for Her Majesty’s Revenue & Customs
Respondents
Procedural Posture
Customs Duty Classification Appeal / First Tier Tribunal (tax Chamber) Decision
Legal Issues
- 1 Whether portable gas detectors should be classified under heading 8531 (alarms) or 9027 (gas analysis apparatus) of the Combined Nomenclature
- 2 Whether the devices perform analysis as required by heading 9027
- 3 Application by analogy of Commission Implementing Regulation 2018/1208
Ratio Decidendi
The Altair portable gas detectors have as a main function the analysis and display of the composition of ambient gases, not merely alerting. This analysis function brings them within heading 9027 of the Combined Nomenclature. The devices are not properly classifiable under heading 9026 (measurement of gas level) or heading 8531 (alarms), as 9027 is more specific and prevails by application of the Section and Chapter Notes and the General Interpretative Rules. The reasoning in Commission Implementing Regulation 2018/1208 applies by analogy, supporting classification under 9027.
Court Disposition
Appeal dismissed
Orders
- The Altair portable gas detectors are properly classified under heading 9027 of the Combined Nomenclature.
Full Case Text
Judgment text and source record
Sign in to read
Sign in to read the full judgment text
Sign in to read the full judgment text. Downloads and additional research tools may depend on your plan.
Sign in to read the full judgment