Boilers Pressure Vessels Regulation 1
This regulation sets safety rules for boilers, pressure vessels, pressure piping, fittings, and related plants, including design approval, permits, inspections, and operating requirements.
- Jurisdiction
- Canada — Northwest Territories
- Instrument
- Regulation
- Version
- Undated source snapshot
- Language
- en
- Official source
- View official record ↗
Statute overview
About this statute
This regulation sets safety rules for boilers, pressure vessels, pressure piping, fittings, and related plants, including design approval, permits, inspections, and operating requirements. Plant owners or those in charge must follow shutdown and notice steps, keep supervision and records in order, and qualifications are managed through the chief inspector. This part sets examination, qualification, and welding-card rules: candidates must apply on time, take exams as directed, meet pass marks, and pay required fees; the chief inspector and inspectors have specified powers over credits, testing, issuing certificates, and requalification. This provision sets fees for qualification tests, certificates, record searches, copies, and related welding documents.
Search within this statute
Search all stored provisions in this version.
Legal text
Provisions of Boilers Pressure Vessels Regulation 1
Showing 4 of 4
Part document.segment-1
Boilers Pressure Vessels Regulation 1 — segment 1
- document.segment-1 Verify source ↗
Boilers Pressure Vessels Regulation 1 — segment 1
This regulation sets safety rules for boilers, pressure vessels, pressure piping, fittings, and related plants, including design approval, permits, inspections, and operating requirements.
BOILERS AND PRESSURE VESSELS ACT LOI SUR LES CHAUDIÈRES ET APPAREILS À PRESSION BOILERS AND PRESSURE VESSELS RÈGLEMENT SUR LES CHAUDIÈRES REGULATIONS ET APPAREILS À PRESSION R-006-93 R-006-93 In force April 1, 1993 En vigueur le 1er avril 1993 AMENDED BY MODIFIÉ PAR R-076-97 R-076-97 R-026-98 R-026-98 In force April 1, 1998 En vigueur le 1er avril 1998 R-053-2001 R-053-2001 In force April 1, 2001 En vigueur le 1er avril 2001 R-060-2005 R-060-2005 In force April 1, 2005 En vigueur le 1er avril 2005 R-016-2013 R-016-2013 In force April 1, 2013 En vigueur le 1er avril 2013 R-078-2013 R-078-2013 R-034-2015 R-034-2015 In force April 1, 2015 En vigueur le 1er avril 2015 R-040-2015 [F] R-040-2015 R-019-2016 R-019-2016 R-085-2024 R-085-2024 R-123-2024 R-123-2024 R-033-2026 R-033-2026 In force June 15, 2026 En vigueur le 15 juin 2026 This consolidation is not an official statement of the La présente codification administrative ne constitue pas law. It is an office consolidation prepared by le texte officiel de la loi; elle n’est établie qu’à titre Legislation Division, Department of Justice, for documentaire par les Affaires législatives du ministère convenience of reference only. The authoritative text of de la Justice. Seuls les règlements contenus dans les regulations can be ascertained from the Revised Règlements révisés des Territoires du Nord-Ouest Regulations of the Northwest Territories, 1990 and the (1990) et dans les parutions mensuelles de la Partie II monthly publication of Part II of the Northwest de la Gazette des Territoires du Nord-Ouest ont force Territories Gazette. de loi. This consolidation and other G.N.W.T. legislation can La présente codification administrative et les autres lois be accessed on-line at et règlements du G.T.N.-O. sont disponibles en direct à l’adresse suivante : https://www.justice.gov.nt.ca/en/browse/laws-and-leg islation/ https://www.justice.gov.nt.ca/en/browse/laws-and-leg islation/ BOILERS AND PRESSURE VESSELS LOI SUR LES CHAUDIÈRES ET ACT APPAREILS À PRESSION BOILERS AND PRESSURE VESSELS RÈGLEMENT SUR LES CHAUDIÈRES REGULATIONS ET APPAREILS À PRESSION The Commissioner, on the recommendation of the Le commissaire, sur la recommandation du Minister, under section 57 of the Boilers and Pressure ministre, en vertu de l’article 57 de la Loi sur les Vessels Act and every enabling power, makes the chaudières et appareils à pression et de tout pouvoir Boilers and Pressure Vessels Regulations. habilitant, prend le Règlement sur les chaudières et appareils à pression. INTERPRETATION AND APPLICATION DÉFINITIONS ET CHAMP D'APPLICATION 1. In these regulations, 1. Les définitions qui suivent s'appliquent au présent règlement. "ANSI" means American National Standards Institute; (ANSI) «accessoire» Désigne toute soupape de sûreté, soupape d'arrêt, soupape automatique d'arrêt et de retenue, vanne "approved" means approved by or acceptable to the de purge, soupape de réduction, indicateur de niveau chief inspector; (agréé) d'eau, robinet de jauge, manomètre, injecteur, robinet d'essai, régulateur ou dispositif de contrôle et raccord "ASME" means American Society of Mechanical de tuyauterie fixé ou faisant partie d’une chaudière, Engineers; (ASME) d’un appareil à pression ou d’une installation. (fitting) "CGA" means Canadian Gas Association; (CGA) «ACNOR» Association canadienne de normalisation, dont l’acronyme CSA est conservé dans le titre des "CSA" means Canadian Standards Association; codes. (CSA) (ACNOR) «agréé» Agréé par le chef inspecteur ou acceptable "fitting" means a safety valve, stop valve, automatic selon lui. (approved) stop and check valve, blow down valve, reducing valve, water gauge, gauge cock, pressure gauge, injector, test «ANSI» American National Standards Institute. (ANSI) cock, regulating and controlling device and pipe fitting attached to or forming part of a boiler, pressure vessel «ASME» American Society of Mechanical Engineers. or plant; (accessoire) (ASME) "high pressure plant" means the complete installation of «certificat de non-standardisation» Certificat de one or more boilers, engines, turbines, piping, qualification délivré à une personne qui n’a pas été machinery and accessories carrying admise à l’examen de normalisé de mécanicien en (a) steam pressure greater than 103 kPa, or installation d’énergie. Cet examen est homologué par le (b) water pressure greater than 1,103 kPa if Comité de normalisation des examnes des mécaniciens the water temperature is greater than en installation d’énergie, désigné par le Canadian 121 C; (installation à haute pression) Association of Chief Inspectors. (non-standardized certificate) "low pressure plant" means a plant of one or more boilers carrying «CGA» Association canadienne du gaz. (CGA) (a) steam pressure not greater than 103 kPa, «conduite sous pression» Tuyau ou corps cylindrique or utilisé pour amener les liquides dans l’appareil à (b) water pressure not greater than 1,103 kPa; pression et les évacuer. (pressure piping) (installation à basse pression) 1 "NBBI" means (American) National Board of Boiler «installation à basse pression» Montage d’une ou and Pressure Vessel Inspectors; (NBBI) plusieurs chaudières soumises : a) à une pression de vapeur d’au plus "non-standardized certificate" means a certificate of 103 kPa; qualification issued to an individual who has not passed b) à une pression de vapeur d’au plus a standardized power engineer’s examination approved 1103 kPa. (low pressure plant) by the Standardization of Power Engineers’ Examination Committee, appointed by the Canadian «installation à haute pression» Montage complet d’un Association of Chief Inspectors; (certificat de ou plusieurs moteurs, chaudières, turbines, tuyauteries, non-standardisation) outillages et accessoires soumis : a) à une pression de vapeur d’au "pressure piping" means a pipe or tubing used for moins 103 kPa; transmitting fluid to or from a pressure vessel; b) à une pression de vapeur d’au moins 1103 (conduite sous pression) kPa si la température de l’eau est d’au moins 121 C. (high pressure plant) "regulated equipment" means equipment to which the Act applies. (matériel réglementé) «matériel réglementé» Matériel visé par la Loi. R-078-2013,s.2; R-019-2016,s.2(1). (regulated equipment) «NBBI» (American) National Board of Boiler and Pressure Vessel Inspectors. (NBBI) R-078-2013, art. 2; R-019-2016, art. 2(1). 1.1. For greater certainty, a reference to a certificate of 1.1. Il est entendu que le renvoi au certificat de qualification in these regulations, except in qualification dans le présent règlement, sauf au subsection 31(1), includes a reference to a paragraphe 31(1), vaut renvoi au certificat de non-standardized certificate. R-019-2016,s.2(2). non-standardisation. R-019-2016, art. 2(2). 2. These regulations apply 2. Le présent règlement vise : (a) to all boilers, pressure vessels and plants a) toute chaudière, tout appareil à pression et to which the Act applies; toute installation visés par la Loi; (b) to all pressure piping, fittings or other b) toute tuyauterie, tout accessoire ou tout equipment attached to or used in autre matériel installé sur les chaudières connection with boilers or pressure ou les appareils à pression visés par la Loi vessels to which the Act applies; ou utilisé en relation avec ces derniers; (c) to all operating engineers, operators and c) tout mécanicien et opérateur de machines welding operators to whom the Act fixes, et tout soudeur visé par la Loi; applies; and d) tout travail effectué sur des chaudières, (d) to all work performed on boilers, pressure appareils à pression et matériels vessels, plants and equipment referred to mentionnés aux alinéas a) et b). in paragraphs (a) and (b). PART I PARTIE I BOILERS, PRESSURE VESSELS, CHAUDIÈRES, APPAREILS À PRESSION, PRESSURE PIPINGS AND CONDUITES SOUS PRESSION ET PLANTS INSTALLATIONS Adoption of Codes and Standards Adoption des codes et des normes 3. Subject to these regulations, the standards 3. Sous réserve du présent règlement, les normes governing the design, fabrication, installation, relatives à la conception, à la fabrication, au montage, identification, testing and inspection of boilers, pressure à l’identification, à l’essai et à l’inspection des 2 vessels, pressure piping and fittings are those set out in chaudières, appareils à pression, conduites sous the following codes or standards or sections of codes or pression et accessoires sont établies aux codes ou aux standards, as amended from time to time: normes qui suivent, ou à leurs articles respectifs, avec (a) CSA B51 Boiler, Pressure Vessel and leurs modifications successives : Pressure Piping Code; a) CSA B51 Code sur les chaudières, (b) CSA B52 Mechanical Refrigeration appareils et tuyauteries sous pression; Code; b) CSA B52 Code sur la réfrigération (c) CSA-Z276 Liquefied Natural Gas (LNG) - mécanique; Production, Storage, and Handling; c) CSA Z276 Gaz naturel liquéfié (GNL) - (d) CSA Z662 Oil and Gas Pipeline Systems; Production, stockage et manutention; (e) CSA Z7396.1 Medical Gas Pipeline d) CSA Z662 Réseaux de canalisations de Systems - Part 1: Pipelines for Medical pétrole et de gaz; Gases, Medical Vacuum, Medical Support e) CSA Z7396.1 Réseaux de canalisation de Gases, and Anaesthic Gas Scavenging gaz médicaux - Partie 1 : Canalisations Systems; pour les gaz médicaux, l’aspiration (f) CAN/CSA-Z10524-2 Pressure Regulators médicale, les gaz au soutien médical et les for use with Medical Gases - Part 2: systèmes d’évacuation de gaz Manifold and Line Pressure Regulators; d’anesthésie; (g) CAN/CSA-Z15002 Flow-metering f) CAN/CSA-Z10524-2 Détendeurs pour Devices for Connection to Terminal Units l’utilisation avec les gaz médicaux - of Medical Gas Pipeline Systems; Partie 2 : Détendeurs de rampes et de (h) CSA B139 Installation Code for Oil canalisations; Burning Equipment; g) CAN/CSA-Z15002 Dispositifs de mesure (i) CSA B149.1 Natural Gas and Propane de débit pour raccordement aux prises Installation Code; murales des systèmes de distribution de (j) CSA B149.2 Propane Storage and gaz médicaux; Handling Code; h) CSA B139 Code d’installation des (k) CSA B149.3 Code for the Field Approval appareils de combustion au mazout; of Fuel-Related Components on i) CSA B149.1 Code d’installation du gaz Appliances and Equipment; naturel et du propane; (l) ASME Boiler and Pressure Vessel Code; j) CSA B149.2 Code sur le stockage et la (m) ASME B.16.5 Pipe Flanges and Flanged manipulation du propane; Fittings: NPS 1/2 through NPS 24 k) CSA B149.3 Code d’approbation sur Metric/Inch Standard; place des composants relatifs au (n) ASME CSD-1 Controls and Safety combustible des appareils et Devices for Automatically Fired Boilers; appareillages; (o) ANSI/CGA G-2.1 Requirements for the l) ASME Boiler and Pressure Vessel Code; Storage and Handling of Anhydrous m) ASME B.16.5 Pipe Flanges and Flanged Ammonia; Fittings: NPS 1/2 through NPS 24 (p) NBBI National Board Inspection Code Metric/Inch Standard; NB23 - System Design, Specifications, n) ASME CSD-1 Controls and Safety Operation, and Inspection of Deaerators; Devices for Automatically Fired Boilers; (q) National Building Code of Canada, issued o) ANSI/CGA G-2.1 Requirements for the by the National Research Council of Storage and Handling of Anhydrous Canada. Ammonia; R-019-2016,s.3. p) NBBI National Board Inspection Code NB23 - System Design, Specifications, Operation, and Inspection of Deaerators; q) le Code national du bâtiment du Canada publié par le Conseil national de recherches du Canada. R-019-2016, art. 3. 3 Approval and Registration of Designs Agrément et enregistrement des conceptions 4. (1) The design and specifications of a proposed 4. (1) La conception et les spécifications proposées boiler or pressure vessel must be submitted in duplicate pour la chaudière ou l’appareil à pression sont soumises to the chief inspector for survey, approval and en double exemplaire au chef inspecteur pour expertise, registration in accordance with the rules set out in the agrément et enregistrement, en conformité avec les CSA B51 Code for the Construction and Inspection of règles établies à la norme CSA Code B51 pour la Boilers and Pressure Vessels. construction et l’inspection des chaudières et appareils à pression. (2) The design and specifications must include (2) La conception et les spécifications (a) maximum operating pressures and comprennent : temperatures; a) les pressions et températures maximales (b) details of the arrangement and dimensions de service; of all component parts; b) le détail du système et les dimensions de (c) the ASME specification number of all toutes les pièces; materials; c) le numéro de série ASME de tout (d) details of fabrication; matériau; (e) the paragraph number of the applicable d) le procédé de fabrication; code or standard under which the boiler or e) le numéro de l’alinéa de la norme ou du pressure vessel is to be constructed; code pertinent en vertu duquel la (f) the registration number of all fittings chaudière ou l’appareil à pression sera included in the design; construit; (g) the welding procedure registration f) le numéro d’enregistrement des number; and accessoires inclus dans la conception; (h) a report of the physical tests conducted for g) le numéro d’enregistrement de la méthode the purpose of establishing the working de soudure; pressure of the pressure vessel, if the h) le rapport sur l’essai physique mené dans design and specifications relate to a le but d’établir la pression effective de pressure vessel. l’appareil à pression, s’il s’agit de la conception et des spécifications ayant trait à un appareil à pression. (3) If a fitting is to be attached to a boiler or (3) Si un accessoire doit être fixé sur une pressure vessel but does not form an integral part of that chaudière ou un appareil à pression, mais qu’il n’en fait boiler or pressure vessel, pas partie intégrante : (a) the size, rating and details of attachment a) les dimensions, la catégorie et le détail de must be included in the design and la fixation doivent apparaître dans la specifications; and conception et les spécifications; (b) the fitting must be approved and b) les accessoires doivent être agréés et registered by the chief inspector before a enregistrés par le chef inspecteur avant certificate of inspection is issued under the qu’un certificat d’inspection ne soit Act. délivré en vertu de la Loi. (4) The appropriate fee set out in the Schedule for (4) Le droit approprié fixé à l’annexe pour the survey, approval and registration of a design of a l’expertise, l’agrément et l’enregistrement de la boiler or pressure vessel shall be paid on the conception d’une chaudière ou d’un appareil à pression registration of the design. R-078-2013,s.2,3(1),4. est payé lors de de l’enregistrement de cette conception. R-078-2013, art. 2 et 3; R-019-2016, art. 4. 5. (1) The design and specifications of a proposed 5. (1) La conception et les spécifications d’une plant must be submitted in duplicate to the chief installation proposée doivent être soumises en double inspector for survey, approval and registration in exemplaire au chef inspecteur pour expertise, agrément 4 accordance with the rules set out in the CSA B51 Code et enregistrement, en conformité avec les règles établies for the Construction and Inspection of Boilers and à la norme CSA Code B51 pour la construction et Pressure Vessels. l’inspection des chaudières et appareils à pression. (2) The design and specifications must include (2) La conception et les spécifications (a) flow or line diagrams showing the general comprennent : arrangement of all pressure vessels, a) tout schéma ou graphique indiquant la pressure piping, fittings, provision for disposition générale de tous les appareils expansion and anchor points; à pression, tuyauteries sous pression et (b) pipeline identification lists showing the accessoires, ainsi que l’expansion maximum pressures and temperatures at éventuelle et les points d’attache; which each part of the plant will operate; b) toute liste d’identification de la (c) a list of pressure relief devices; canalisation indiquant les pressions et (d) material specifications, sizes, schedules températures maximales de service and primary service ratings of all pressure auxquelles seront soumises chacune des pipes and fittings; parties de l’installation; (e) the registration number of all fittings and c) la liste des dispositifs de réduction de la pressure vessels included in the drawings; pression; and d) les caractéristiques, les dimensions, les (f) the welding procedure registration number barèmes et les catégories de service given under subsection 13(1). principal de toute tuyauterie sous pression et accessoires; e) le numéro d’enregistrement de tous les appareils à pression et de leurs accessoires apparaissant aux dessins; f) le numéro d’enregistrement de la méthode de soudure donné en vertu du paragraphe 13(1). (3) The design and specifications for the following (3) La conception et les spécifications pour les plants need not be submitted for approval unless installations suivantes n’ont pas à être déposées pour required by the chief inspector, but such plants must agrément, à moins que le chef inspecteur ne l’exige. De otherwise comply with these regulations: telles installations doivent, cependant, en tout autre (a) a high pressure plant that does not exceed point, être conformes au présent règlement : 929 kW; a) l’installation à haute pression qui est d’au (b) a steam plant carrying a pressure not plus 929 kW; exceeding 103 kPa; b) l’installation à vapeur dont la pression est (c) a hot water plant carrying a pressure not d’au plus 103 kPa; exceeding 1,103 kPa; c) l’installation à eau chaude dont la pression (d) a refrigeration plant not exceeding 10.5 est d’au plus 1 103 kPa; kW; d) l’installation frigorifique d’au plus (e) an oil and gas processing plant or 10,5 kW; compressor station where the pressure e) la raffinerie de pétrole ou la station piping does not exceed 0.510 m³ d’épuration de gaz dont la capacité interne aggregate internal capacity. totale de la tuyauterie ou de la canalisation est d’au plus 0,510 m³. (4) The fee set out in the Schedule for the survey, (4) Le droit fixé à l’annexe pour l’expertise, approval and registration of a design of a plant shall be l’agrément et l’enregistrement de la conception d’une paid on the registration of the design. R-078-2013,s.5. installation est payé lors de l’enregistrement de la conception. R-019-2016, art. 4. 5 6. (1) The design and specifications of fittings or 6. (1) La conception et les spécifications des accessories proposed for use in connection with boilers accessoires ou autres pièces d’équipement, dont l’usage or pressure vessels must be submitted in duplicate to the est projeté en relation avec les chaudières et appareils chief inspector for survey, approval and registration in à pression, doivent être déposées en double auprès du accordance with the rules set out in the CSA B51 Code chef inspecteur pour expertise, agrément et for the Construction and Inspection of Boilers and enregistrement en conformité avec les régles établies à Pressure Vessels. la norme CSA Code B51 pour la construction et l’inspection des chaudières et appareils à pression. (2) The design and specifications must include (2) La conception et les spécifications (a) details of the arrangement and dimensions comprennent : of all component parts; a) le détail du système et les dimensions de (b) material specifications; toutes les pièces; (c) maximum operating pressures and b) les caractéristiques importantes; temperatures; c) les pressions et températures maximales (d) the test pressure to which each fitting will de service; be subjected by the manufacturer; and d) l’épreuve de pression à laquelle chaque (e) a report of any physical tests conducted accessoire sera soumis par le fabricant; for the purpose of establishing the e) tout rapport sur les essais physiques working pressures of a fitting. menés dans le but d’établir la pression effective d’un accessoire. (3) If a standard series of fittings complies with all (3) Si un ensemble standard d’accessoires the requirements of the ASME codes and ANSI rencontre toutes les exigences des codes ASME et des standards as to their dimensions, identification and normes ANSI relativement à leurs dimensions, leur materials in respect of the service for which they are identification et leurs matériaux, compte tenu de l’usage required, the manufacturer may have the standard series pour lesquels ils sont requis, le fabricant peut faire of fittings registered collectively in catalogue form by enregistrer l’ensemble standard des accessoires submitting to the chief inspector, in duplicate, a collectivement, sous forme de catalogue, en soumettant statutory declaration in the approved form respecting au chef inspecteur une formule de déclaration the registration of such fittings. solennelle en double exemplaire selon la forme établie relative à l’enregistrement de ces accessoires. (4) The appropriate fee set out in the Schedule for (4) Le droit approprié fixé à l’annexe pour the survey, approval and registration of a design of l’expertise, l’agrément et l’enregistrement de la fittings shall be paid on the registration of the design. conception des accessoires est payé lors de l’enregistrement de la conception. (5) If a design for fittings is approved and (5) Si la conception des accessoires est agréée et registered and a manufacturer supplies fittings that do enregistrée, et qu’un fabricant fournit des accessoires not comply with the approved design, the chief qui n’y correspondent pas, le chef inspecteur en annule inspector shall cancel the registration number for the le numéro d’enregistrement et peut refuser d’examiner design and may refuse to consider a further application toute autre demande de ce fabricant pour for registration of fittings from that manufacturer. l’enregistrement des accessoires. (6) If a design for fittings is approved and (6) Si la conception des accessoires est agréée et registered, the chief inspector may enregistrée, le chef inspecteur peut : (a) require the manufacturer of the fittings to a) exiger du fabricant de l’accessoire qu’il submit samples for examination and présente des échantillons pour étude et testing and where the fittings are essai et lorsque les accessoires sont submitted, the chief inspector shall, at the soumis, le chef inspecteur, à la demande et request and expense of the manufacturer, aux frais du fabricant, les lui retourne dans return them to the manufacturer within 90 les 90 jours suivant la demande; 6 days after the request; and b) choisir n’importe lequel des accessoires (b) select any fitting from the stock of an de l’inventaire de l’agent du fabricant agent of the manufacturer and test it. pour en faire l’essai. (7) If a fitting is tested under subsection (6), the (7) Si un accessoire est mis à l’essai en vertu du manufacturer shall pay the fee set out in the Schedule paragraphe (6), le fabricant doit payer le droit fixé à for the survey, approval and registration of a design of l’annexe pour l’expertise, l’agrément et fittings. l’enregistrement de la conception de l’accessoire. (8) If a fitting proves faulty when tested under (8) Le chef inspecteur peut annuler le numéro subsection (6), the chief inspector may cancel the d’enregistrement de la conception d’un accessoire qui, registration number for the design of that fitting. après un essai fait en vertu du paragraphe 6, s’avère être R-078-2013,s.6(1). défectueux. R-078-2013, art. 6(1); R-019-2016, art. 4. 7. (1) Subject to subsection (2), the chief inspector 7. (1) Sous réserve du paragraphe (2), le chef shall approve a design where the design complies in all inspecteur approuve la conception lorsqu’elle est details with the requirements of these regulations and of conforme en tous points aux exigences du présent the pertinent sections of the codes or standards set out règlement et aux articles pertinents des codes ou des in section 3 and, where the design is for normes visés à l’article 3 et, lorsqu’il s’agit de la (a) a boiler, pressure vessel or fitting, the conception : boiler, pressure vessel or fitting is already a) d’une chaudière, d’un appareil à pression approved for use in a province or another ou d’un accessoire dont l’utilisation, dans territory; or une province ou dans un autre territoire, a (b) a boiler or pressure vessel, the boiler or déjà été agréée; pressure vessel is being manufactured for b) d’une chaudière ou d’un appareil à use exclusively in the Northwest pression qui est en cours de fabrication Territories. pour une utilisation exclusive dans les Territoires du Nord-Ouest. (2) If a formula has not been provided in a code or (2) Si une formule d’évaluation n’est pas prévue standard referred to in section 3 for a particular dans le code ou la norme mentionné à l’article 3 pour measurement or other procedure, the chief inspector une mesure spéciale ou autre procédure, le chef may accept or reject an alternate evaluation procedure inspecteur peut accepter ou rejeter toute autre proposed by the manufacturer. procédure d’évaluation proposée par le fabricant. (3) If circumstances require an alteration or (3) Si les circonstances nécessitent une modification to established methods of fabrication, the modification à l’établissement des procédés de chief inspector may accept or reject an alternate method fabrication, le chef inspecteur peut accepter ou rejeter of fabrication. tout autre procédé. (4) The chief inspector shall assign a registration (4) Le chef inspecteur donne un numéro number to a design for a boiler, pressure vessel or d’enregistrement à la conception d’une chaudière, d’un fitting that has been approved under subsection (1) in appareil à pression ou d’un accessoire qui a été agréé en accordance with the CSA B51 Code for the vertu du paragraphe (1) en conformité avec le Code Construction and Inspection of Boilers and Pressure B51 pour la construction et l’inspection des chaudières Vessels. R-078-2013,s.6(1),7,8(1). et appareils à pression. R-078-2013, art. 6(1), 7, 8(1). 8. If a design is approved and registered by the chief 8. Si la conception est agréée et enregistrée par le chef inspector, the chief inspector shall return a copy of the inspecteur, celui-ci en retourne une copie au design and specifications indicating the registration concepteur, accompagnée des spécifications indiquant number and limits on working pressures and le numéro d’enregistrement et les limites de pressions temperatures to the person that submitted the design et de températures effectives. Le concepteur peut par la and the person may then manufacture and distribute suite fabriquer et distribuer les chaudières, appareils à 7 boilers, pressure vessels or fittings in any number in pression ou les accessoires en nombre illimité en accordance with that design. R-078-2013,s.6(1). conformité avec la conception. R-078-2013, art. 6(1). 9. If a design is not approved, the chief inspector shall 9. Si la conception n’est pas agréée, le chef inspecteur send a report to the person that submitted the design envoie au concepteur un rapport motivé. R-078-2013, setting out the reasons why the design was not art. 6(1). approved. R-078-2013,s.6(1). 10. Notwithstanding the approval of a design, if the 10. Malgré son agrément, si la conception présente par design subsequently proves to be defective in any la suite des vices dans l’un des éléments décrits, le chef particular, the chief inspector shall notify the inspecteur avise le fabricant qui, sur réception de cet manufacturer and, on receipt of notification, the avis, révise la conception afin d’obtenir l’agrément du manufacturer shall revise the design to meet the chef inpecteur. approval of the chief inspector. 11. The approval or registration of a design does not 11. L’agrément ou l’enregistrement d’une conception relieve the manufacturer of responsibility for the design ne libère pas le fabricant de sa responsbilité face à la and manufacture of any fitting, boiler or pressure conception et à la fabrication de tout accessoire, vessel. chaudière ou appareil à pression. 12. (1) A manufacturer who revises a design of a 12. (1) Un fabricant qui révise la conception d’une boiler, pressure vessel or fitting that has been approved chaudière, d’un appareil à pression ou d’un accessoire shall submit to the chief inspector details of the qui a été approuvée doit, en double exemplaire, revision, in duplicate, for the survey, approval and soumettre au chef inspecteur les détails de la révision registration. pour expertise, agrément et enregistrement. (2) If the chief inspector considers the changes (2) Si le chef inspecteur considère que les referred to in subsection (1) sufficiently extensive, the changements visés au paragraphe (1) sont suffisamment chief inspector may require a complete re-submission of importants, il peut exiger un nouveau dépôt de la the design and specifications. conception et des spécifications. (3) If the design and specifications must be re- (3) Ces nouvelles conceptions et spécifications submitted under subsection (2), the design and sont soumises en double exemplaire au chef inspecteur. specifications must be submitted in duplicate to the chief inspector. (4) Subject to subsection (5), the fee set out in the (4) Sous réserve du paragraphe (5), le droit fixé à Schedule for the survey, approval and registration of a l’annexe pour l’expertise, l’agrément et design that is revised shall be paid on the registration of l’enregistrement de la conception révisée est payé lors the design. de son enregistrement. (5) If the design and specifications are re- (5) Le droit fixé à l’annexe pour l’expertise, submitted under subsection (3), the fee set out in the l’agrément et l’enregistrement de la nouvelle Schedule for the survey, approval and registration of a conception est payé lors de son enregistrement. R-078- design shall be paid on the registration of the design. 2013, art. 6(1). R-078-2013,s.4,6,9. Welding Procedures Les méthodes de soudure 13. (1) Welding procedures must be approved and 13. (1) Les méthodes de soudure doivent être agréées registered in accordance with the codes and standards et enregistrées en conformité avec les codes et les set out in section 3. normes mentionnés à l’article 3. 8 (2) The fee set out in the Schedule for the review (2) Le droit fixé à l’annexe pour l’examen et and approval of a welding procedure shall be paid on l’agrément d’une méthode de soudure est payé lors de the registration of the procedure. son enregistrement. (3) All welding tests, in order to be recognized in (3) Afin d’être reconnue dans les Territoires du the Northwest Territories, shall be conducted, Nord-Ouest, toute épreuve de soudure est menée : (a) in the Territories, by an inspector; a) dans les Territoires du Nord-Ouest, par un (b) in a province or another territory, by an inspecteur; inspector approved by the chief inspector b) dans une province ou un autre territoire, of the province or that other territory, as par un inspecteur agréé par le chef the case may be; inspecteur de la province ou de l’autre (c) in the United States, by an inspector who territoire, selon le cas; is the holder of a National Board c) aux États-Unis, par un inspecteur qui Commission; or détient un mandat de la National Board (d) elsewhere, by an inspector employed by Commission; Lloyd’s Register of Shipping or another d) partout ailleurs, par un inspecteur inspection agency approved by the chief travaillant pour Lloyd’s Register of inspector. Shipping ou toute autre agence R-078-2013,s.8(2),10,11. d’inspection agréée par le chef inspecteur. R-078-2013, art. 8(2), 11. Registration of Quality Control Enregistrement des manuels Manuals de contrôle de la qualité 14. (1) A manufacturer or contractor shall, if required 14. (1) Un fabricant ou un entrepreneur doit, si le chef by the chief inspector, and may, at any other time, inspecteur l’exige, ou peut à tout autre moment submit a quality control manual relating to the repair of soumettre un manuel de contrôle de la qualité, relatif à a boiler or pressure vessel to the chief inspector for la réparation d’une chaudière ou d’un appareil à review, approval and registration. pression, au chef inspecteur pour examen, agrément et enregistrement. (2) A quality control manual shall include (2) Un manuel de contrôle de la qualité doit (a) details of repair methods; comprendre : (b) details of the responsibilities of the person a) les détails des méthodes de réparation; submitting the manual; b) les détails des responsabilités de la (c) material specifications; personne qui soumet le manuel; (d) details of welding procedures; c) les descriptions précises du matériel; (e) details of inspection procedures; and d) les détails des méthodes de soudure; (f) such other information, plans, drawings or e) les détails des méthodes d’inspection; reports as the chief inspector considers f) tout autre renseignement, plan, dessin ou appropriate. rapport que le chef inspecteur estime utile. (3) The fee set out in the Schedule for the review (3) Les droits fixés à l’annexe pour l’examen et and approval of a quality control manual shall be paid l’agrément d’un manuel de contrôle de la qualité sont on the registration of the manual. R-078-2013,s.10. payés lors de l’enregistrement de ce manuel. Installation, Inspections and Operation Montage, inspections et fonctionnement 15. Before commencing fabrication of a boiler or 15. Avant de commencer la fabrication d’une chaudière pressure vessel to be built under these regulations, the ou d’un appareil à pression construit en vertu du présent manufacturer shall give to an inspector the approved règlement, le fabricant fournit à un inspecteur la design and specifications. conception agréée et les spécifications. 9 16. (1) If a boiler or pressure vessel is to be delivered 16. (1) Si une chaudière ou un appareil à pression est to a user within the Northwest Territories, the livré à un utilisateur dans les Territoires du Nord-Ouest, manufacturer shall forward to the chief inspector a le fabricant envoie au chef inspecteur un rapport rédigé report in the approved form. selon la forme établie. (2) If pressure piping is shop fabricated by (2) Si une conduite sous pression est fabriquée en welding, the person responsible for the fabrication shall atelier par procédé de soudure, la personne responsable forward to the chief inspector a report in the approved de sa fabrication doit envoyer un rapport rédigé selon la form. forme établie. (3) Subject to subsection (4), if the report referred (3) Sous réserve du paragraphe (4), si le rapport to in subsection (1) or (2) is not complete in all visé aux paragraphes (1) et (2) n’est pas rempli dans particulars, the chief inspector shall not approve the tous les détails, le chef inspecteur refuse de donner son boiler or pressure vessel or the pressure piping, as the agrément de la chaudière, ou de l’appareil à pression ou case may be. de la conduite sous pression, selon le cas. (4) If the ultimate user’s name and the location of (4) Si le fabricant ne connaît ni le nom de installation is unknown to the manufacturer, it may be l’utilisateur final, ni le lieu de la mise en place du omitted from the report referred to in subsection (1) or montage, il peut omettre ces renseignements dans le (2) and filled in by the manufacturer’s sales rapport visé aux paragraphes (1) et (2) et les déposer representative who shall, at the time of the sale, par la suite par le biais de son représentant des ventes forward the report to the chief inspector. qui envoie, au moment de la vente, le rapport au chef R-078-2013,s.2,6(1),8(2). inspecteur. R-078-2013, art. 2, 6(1). 17. No person shall install, alter, repair or add to a 17. Il est interdit d’installer, de modifier, de réparer ou boiler, pressure vessel or pressure piping system unless d’ajouter quelque chose à une chaudière, à un appareil that person has an installation permit entitling him or à pression ou à un système de conduite sous pression, à her to do so. moins qu’un permis de montage ne l’autorise. 18. On application and on payment of the fee set out in 18. Le chef inspecteur délivre un permis de montage à the Schedule, the chief inspector shall issue an un monteur qui a envoyé une demande en vertu du installation permit to an installer who, in the opinion of paragraphe (2) et qui, de l’avis du chef inspecteur, est the chief inspector, is qualified to do the work for which qualifié pour faire le travail visé par le the installation permit is issued. R-060-2005,s.3. permis. R-060-2005, art. 3. 19. (1) An installer shall install a boiler or pressure 19. (1) Un entrepreneur monte une chaudière ou un vessel in such a way that it is readily accessible for appareil à pression de telle manière, qu’il soit aisément external and internal cleaning and inspection. accessible pour le nettoyage et l’inspection interne et externe. (2) An installer shall provide sufficient clearance (2) L’entrepreneur prévoit un espace suffisant around a boiler or pressure vessel that is being installed autour de la chaudière ou de l’appareil à pression à to permit the proper installation of necessary fittings monter pour permettre le montage adéquat des and pressure piping. accessoires et des conduites sous pression. (3) An installer shall provide enough clearance (3) Il prévoit également assez d’espace autour de around a boiler or pressure vessel that is being installed la chaudière ou de l’appareil à pression à monter pour to permit tube renewal. permettre le remplacement des conduits. 10 (4) If it is impractical to provide adequate space (4) S’il n’est pas possible de prévoir suffisamment for thorough inspection, an installer shall install a boiler d’espace pour une inspection approfondie, or pressure vessel in such a way that it can be readily l’entrepreneur monte la chaudière ou l’appareil à removed to permit inspection. R-078-2013,s.6(1). pression de telle manière qu’il puisse être facilement enlevé afin de permettre l’inspection. R-078-2013, art. 6(1). 20. No person shall cover welded repairs on a boiler, 20. Nul ne peut recouvrir les réparations par soudure sur pressure vessel or pressure piping system with une chaudière, un appareil à pression ou un système de insulation or any other material until authorized to do so conduite sous pression d’un isolant ou tout autre matériau by an inspector. tant que l’inspecteur n’en a pas donné l’autorisation. 21. An installer shall install a boiler in conformity with 21. L’entrepreneur monte la chaudière en conformité the codes and standards set out in section 3. avec les codes et les normes visés à l’article 3. 22. The installer who installs a boiler or pressure vessel 22. L’entrepreneur qui monte une chaudière ou un shall arrange for an initial inspection by an inspector appareil à pression fixe une première inspection menée before the boiler or pressure vessel is put into service. par un inspecteur avant que la chaudière ou l’appareil à pression ne soit mis en service. 23. On completion of the initial inspection of a boiler 23. Suite à la première inspection d’une chaudière ou or pressure vessel, the inspector shall d’un appareil à pression, l’inspecteur : (a) assign an identification number to the a) donne selon le cas, un numéro boiler or pressure vessel, as the case may d’identification à la chaudière ou à be; and l’appareil à pression; (b) affix a sticker to the boiler or pressure b) appose un autocollant sur la chaudière ou vessel that indicates the identification l’appareil à pression indiquant le numéro number assigned to it or otherwise d’identification qui lui a été donné ou, indicate the identification number on the autrement, indique le numéro d’iden- boiler or pressure vessel in a manner tification sur la chaudière ou l’appareil à specified by the chief inspector. pression de la façon déterminée par le chef inspecteur. 23.1. If a blank flange isolating a boiler in a plant for 23.1. Si une bride obturatrice isolant une chaudière doit which a certificate of inspection or a certificate of être montée ou démontée dans une installation pour approval has been issued is to be installed or removed laquelle un certificat d’inspection ou un certificat and the installation or removal might affect the d’agrément a été délivré et que le montage ou le classification of the plant, the chief operating engineer démontage peuvent affecter la classification de cette of the plant shall advise the chief inspector in writing installation, le mécanicien-opérateur en chef de prior to the installation or removal. R-076-97,s.2; l’installation avise le chef inspecteur par écrit avant le R-078-2013,s.6(1). montage ou le démontage. R-076-97, art. 2; R-078-2013, art. 6(1). 24. (1) An owner intending to operate a boiler or 24. (1) Le propriétaire qui a l’intention de mettre en pressure vessel shall pay the appropriate fee for annual service une chaudière ou un appareil à pression doit registration set out in the Schedule on or before April payer le droit approprié pour l’enregistrement annuel 30 of each year in which the owner intends to operate fixé à l’annexe au plus tard le 30 avril de chaque année the boiler or pressure vessel. de mise en service par le propriétaire de la chaudière ou de l’appareil à pression. (2) Every operating boiler or pressure vessel is (2) Toute chaudière ou tout appareil à pression en subject to such periodic inspections as may be required fonction est soumis aux inspections périodiques que le by the chief inspector, with the following exceptions: chef inspecteur exige, sous réserve des exceptions 11 (a) a pressure vessel that is used to contain suivantes : anhydrous ammonia or liquified a) l’appareil à pression qui est utilisé pour petroleum products and that is mounted on contenir de l’ammoniaque anhydre ou des a vehicle subject to the Public Service produits de pétrole liquéfiés et qui est Vehicles Act; monté sur un véhicule assujetti à la Loi (b) a storage vessel used to contain anhydrous sur les véhicules de transport public; ammonia or liquified petroleum products b) le réservoir d’emmagasinage contenant de having a capacity not exceeding 9,100 ; l’amoniaque anhydre ou des produits de (c) a hydro-pneumatic vessel not exceeding pétrole liquéfiés dont la capacité n’excède 0.61 m in diameter or that is not supplied pas 9 100 l; with air from an outside source; c) le réservoir hydropneumatique n’excè- (d) an air-oil receiver not exceeding 0.043 m3; dant par 0,61 m de diamètre ou qui ne (e) an air cooled type heat exchanger; reçoit pas d’air d’une source extérieure; (f) a suction, discharge, scrubber or pulsation d) le réservoir air-huile qui n’excède pas vessel for a compressor having a volume 0,043 m3; not exceeding 0.043 m3; e) l’échangeur de chaleur refroidi par l’air; (g) a pressure vessel not exceeding 0.043 m3 f) l’appareil à succion, décharge, lavage et in volume installed in a refrigeration injection pour le compresseur dont le plant; volume n’excède pas 0,043 m3; (h) a pressure vessel forming an integral part g) l’appareil à pression, dont le volume of a pressure piping system that has been n’exède pas 0,043 m3, monté dans une classified by the chief inspector as part of installation frigorifique; the pressure piping. h) l’appareil à pression faisant partie intégrante du système de conduite sous pression qui a été classé par le chef inspecteur comme faisant partie de ce système de conduite sous pression. (3) A boiler or pressure vessel referred to in (3) La chaudière ou l’appareil à pression paragraphs (2)(a) to (h) may, in the discretion of the mentionné aux alinéas (2)a) à h) peut, à la discrétion du chief inspector, be subject to inspections during chef inspecteur, faire l’objet d’inspection pendant la fabrication or installation or when undergoing fabrication, le montage ou lors des modifications ou des alterations or repairs. R-076-97,s.3; R-078-2013,s.12. réparations. R-076-97, art. 3; R-078-2013, art. 12. 25. (1) In the course of an inspection, an inspector 25. (1) Un inspecteur peut, au cours d’une inspection, may reduce the allowable working pressure of a boiler, réduire la pression effective permise d’une chaudière, pressure vessel or pressure piping if the inspector d’un appareil à pression ou d’une conduite sous considers the workmanship, material, condition or pression s’il considère qu’une réduction est exigée installation requires a reduction in working pressure. compte tenu de la main d’oeuvre, des matériaux, de l’état ou de l’installation de l’appareil. (2) In the course of an inspection, an inspector (2) Un inspecteur peut, au cours d’une inspection, may adjust a safety valve that is attached to a boiler, ajuster une valve de sécurité fixée à une chaudière, un pressure vessel or plant and, where such an adjustment appareil à pression ou une installation. Dans ce cas, le is made, the owner shall pay the fee set out in the propriétaire paie le droit fixé à l’annexe. R-078-2013, Schedule. R-078-2013,s.13. art. 13. 26. Before the initial operation of a pressure piping 26. Avant de procéder à la première mise en service system, the owner or a representative of the owner shall d’un système de conduite sous pression, le propriétaire (a) inspect the system to ensure that the ou son représentant doit : materials, identification, fabrication, a) procéder à l’inspection du système pour installation and testing conform to the s’assurer que les matériaux, l’identifi- requirements of these regulations; and cation, la fabrication, le montage et les 12 (b) where the system is a welded pressure essais sont conformes aux exigences du piping system, forward to the chief présent règlement; inspector a report in the approved form. b) transmettre au chef inspecteur un rapport R-078-2013,s.14. rédigé selon la forme établie lorsqu’il s’agit d’un système de conduites sous pression qui a été soudé. Plants Installations 27. (1) Plants are classified as follows: 27. (1) Les installations sont classées de la façon (a) first class includes high pressure plants suivante : capable of generating 10,000 kW; a) la première classe comprend les (b) second class includes high pressure plants installations à haute pression capables de capable of generating 5,000 kW; générer 10 000 kW; (c) third class includes b) la deuxième classe comprend les (i) high pressure plants capable of installations à haute pression capables de generating 2,000 kW, and générer 5 000 kW; (ii) low pressure plants capable of c) la troisième classe comprend : generating 5,000 kW; (i) les installations à haute pression (d) fourth class includes capables de générer 2 000 kW, (i) high pressure plants capable of (ii) les installations à basse pression generating 500 kW, and capables de générer 5 000 kW; (ii) low pressure plants capable of d) la quatrième classe comprend : generating 3,000 kW; (i) les installations à haute pression (e) fifth class includes capables de générer 500 kW, (i) high pressure plants capable of (ii) les installations à basse pression generating 100 kW, and capables de générer 3 000 kW; (ii) low pressure plants capable of e) la cinquième classe comprend : generating 750 kW. (i) les installations à haute pression capables de générer 100 kW, (ii) les installations à basse pression capables de générer 750 kW. (2) If a plant includes both high pressure and low (2) Si une installation comprend à la fois des pressure boilers, both shall be taken into account in chaudières à haute et à basse pression, les deux doivent respect of the classification of the plant. être prises en compte pour la classification de R-078-2013,s.6(1). l’installation. R-078-2013, art. 6(1). 27.1. (1) If the generating capacity of a plant for which 27.1.
Part document.segment-2
Boilers Pressure Vessels Regulation 1 — segment 2
- document.segment-2 Verify source ↗
Boilers Pressure Vessels Regulation 1 — segment 2
Plant owners or those in charge must follow shutdown and notice steps, keep supervision and records in order, and qualifications are managed through the chief inspector.
(1) Si la capacité de production d’une installation a certificate of inspection or a certificate of approval pour laquelle un certificat d’inspection ou un certificat has been issued is to be permanently reduced, the owner d’agrément a été délivré est sur le point d’être réduite or person in charge of the plant shall perform the de façon permanente, le propriétaire de l’installation ou following procedures: la personne qui en a la charge effectue les opérations (a) install a blank flange or disconnect both suivantes : the inlet and outlet lines to the boiler or a) l’installation d’une bride obturatrice ou le boilers that are being disconnected; débranchement des conduites d’entrée et (b) lock out all electrical controls to the boiler de sortie de la chaudière ou des or boilers that are being disconnected and chaudières qui sont débranchées; their accessories; b) le blocage de tous les contrôles électriques (c) lock out and tag all fuel lines leading to de la chaudière ou des chaudières qui sont the burner or burners of the boiler or débranchées et de leurs accessoires; boilers that are being disconnected. c) le blocage et le marquage de toutes les canalisations de carburant qui vont au 13 brûleur ou brûleurs de la chaudière ou des chaudières qui sont débranchées. (2) When the procedures set out in subsection (1) (2) Lorsque les opérations mentionnées au have been completed, the owner or person in charge of paragraphe (1) ont été effectuées, le propriétaire de the plant shall give the chief inspector a written notice l’installation ou la personne qui en a la charge avise le of the permanent reduction of the generating capacity of chef inspecteur par écrit de la réduction permanente de the plant. R-076-97,s.4; R-078-2013,s.6(1). la capacité de production de l’installation. R-076-97, art. 4; R-078-2013, art. 6(1). 27.2. (1) If procedures are to be undertaken to 27.2. (1) Si des opérations doivent être effectuées afin temporarily reduce the generating capacity of a plant de réduire temporairement la capacité de production for which a certificate of inspection or a certificate of d’une installation pour laquelle un certificat approval has been issued, the owner or person in charge d’inspection ou un certificat d’agrément a été délivré, le of the plant shall, before the commencement of those propriétaire de l’installation ou la personne qui en a la procedures, give the chief inspector a written notice of charge avise par écrit le chef inspecteur de la réduction the proposed temporary reduction. temporaire proposée, avant le début de ces opérations. (2) On receiving the notice referred to in (2) Dès réception de l’avis visé au paragraphe (1), subsection (1), the chief inspector may request such le chef inspecteur peut demander du propriétaire de information as he or she considers necessary from the l’installation ou de la personne qui en a la charge tous owner or person in charge of the plant. les renseignements qu’il estime nécessaires. (3) The chief inspector may require the owner or (3) Le chef inspecteur peut exiger du propriétaire person in charge of the plant to perform such de l’installation ou de la personne qui en a la charge procedures as the chief inspector considers necessary to qu’il prenne les mesures que le chef inspecteur estime reduce the generating capacity of the plant. nécessaires afin de réduire la capacité de production de l’installation. (4) When the procedures required to temporarily (4) Lorsque les opérations exigées afin de réduire reduce the generating capacity of a plant have been temporairement la capacité de production de completed, including any required by the chief l’installation ont été effectuées, y compris celles exigées inspector, the owner or person in charge of the plant par le chef inspecteur, le propriétaire de l’installation ou shall give the chief inspector a written notice of their la personne qui en a la charge avise par écrit le chef completion. R-076-97,s.4; R-078-2013,s.6(1). inspecteur de leur exécution. R-076-97, art. 4. R-078- 2013, art. 6(1). 28. (1) Subject to subsection (2), first, second, third 28. (1) Sous réserve du paragraphe (2), les and fourth class plants require continuous supervision installations de première, deuxième, troisième et under subsection 38(2) of the Act. quatrième classe nécessitent une surveillance continue en vertu du paragraphe 38(2) de la Loi. (2) Where there are no persons in a building in (2) Lorsque personne ne se trouve dans un which a first, second, third or fourth class plant is bâtiment qui comprend une installation de première, contained, the plant may be left without continuous deuxième, troisième ou quatrième classe, il n’est pas supervision. nécessaire que cette installation soit continuellement surveillée. 29. (1) In every plant, the owner shall designate one 29. (1) Pour chaque installation, le propriétaire doit person who is the holder of the required certificate of désigner une personne, titulaire du certificat de qualification to be chief operating engineer. qualification requis pour devenir le mécanicien- opérateur en chef. 14 (2) The chief operating engineer is responsible for (2) Le mécanicien-opérateur en chef est the proper care and safe operation of the boilers, responsable des opérations d’entretien et de sécurité des pressure vessels, piping, engines and auxiliaries under chaudières, appareils à pression, conduites, moteurs et his or her charge and shall report all accidents to the matériels annexes qui sont sous sa garde et doit chief inspector and to the owner. rapporter tout accident au chef inspecteur et au propriétaire. 30. The chief operating engineer shall ensure that a log 30. Le mécanicien-opérateur en chef doit s’assurer book is maintained to record all matters relating to the qu’un livret de contrôle est tenu pour enregistrer toute operation of a plant, including a record of the testing affaire relative à l’exploitation d’une installation, y and servicing of safety valves and other safety devices compris l’enregistrement des essais et l’entretien des and controls. valves de sûreté, ainsi que les autres dispositifs et contrôle de sûreté. PART II PARTIE II QUALIFICATIONS, EXAMINATIONS AND COMPÉTENCES, EXAMENS ET CERTIFICATS CERTIFICATION OF OPERATING ENGINEERS DES MÉCANICIENS DE MACHINES FIXES 31. (1) The chief inspector shall issue a certificate of 31. (1) Les certificats de qualification sont délivrés par qualification to a person who satisfies the requirements le chef inspecteur à toute personne qui répond aux for the certificate of qualification. exigences de ce certificat. (2) The owner or person in charge of a plant shall (2) Le propriétaire ou la personne responsable provide the chief inspector with any information the d’une installation fournit au chef inspecteur tout chief inspector may require with respect to the renseignement que celui-ci peut exiger relativement aux qualifications of the personnel involved in the operation compétences du personnel impliqué dans le of the plant. fonctionnement de l’installation. 32. (1) A certificate of qualification, other than a 32. (1) Tout certificat de qualification, autre qu’un temporary certificate, expires three years after the day certificat temporaire, prend fin trois ans après le jour de it is issued, unless sooner cancelled. sa délivrance à moins qu’il ne soit annulé plus tôt. (2) A certificate of qualification may be limited as (2) Tout certificat de qualification peut être limité to purpose or area and, where the certificate is quant à son objet, ou son étendue et, si le certificat est temporary, as to time. temporaire, quant à sa durée du certificat. (3) The chief inspector may, on application, renew (3) Le chef inspecteur peut, sur demande, a certificate of qualification, other than a temporary renouveler un certificat de qualification, à l’exclusion certificate, without examination, if d’un certificat de qualification temporaire, sans faire (a) the chief inspector is of the opinion that passer d’examen, si les conditions suivantes sont the applicant remains qualified for that réunies : class of certificate; a) le chef inspecteur est d’avis que le (b) the application is made within three years demandeur demeure qualifié pour cette after the day the certificate expired; and classe de certificat; (c) the application is accompanied by the fee b) la demande est faite dans les trois années set out in the Schedule. suivant la date d’expiration du certificat; c) la demande est accompagnée du droit fixé à l’annexe. 15 (4) A holder of a certificate of qualification shall (4) Le titulaire d’un certificat de qualification doit requalify for a certificate unless it is renewed in à nouveau se qualifier pour obtenir un autre certificat à accordance with this section. R-076-97,s.5, moins que ce dernier ne soit renouvelé en vertu du R-060-2005, s.3; R-078-2013,s.15; R-019-2016,s.5. présent article. R-076-97, art. 5, R-060-2005, art. 3; R-078-2013, art. 15; R-019-2016, art. 5. 33. (1) The owner or person in charge of a plant shall 33. (1) Le propriétaire ou la personne responsable post the certificates of qualification required under the d’une installation doit afficher bien en vue dans la Act or these regulations in a conspicuous place in the chaufferie les certificats de qualification exigés en vertu boiler room. de la Loi ou du présent règlement. (2) If the certificate of qualification of a person is (2) Une personne peut présenter une demande au required to be posted in more than one boiler room chef inspecteur afin d’obtenir une copie de son under subsection (1), that person may apply to the chief certificat de qualification lorsque ce dernier doit être inspector for a duplicate certificate of qualification. affiché dans plus d’une chaufferie en vertu du paragraphe (1). (3) An application under subsection (2) must be (3) Toute demande en vertu du paragraphe (2) doit accompanied by the fee for the issuance of a duplicate être accompagnée du droit fixé à l’annexe pour la certificate of qualification set out in the Schedule. délivrance d’une copie du certificat de qualification. (4) The chief inspector may issue a duplicate (4) Le chef inspecteur peut délivrer une copie du certificate of qualification for the purposes of certificat de qualification aux fins du paragraphe (1) et subsection (1) and shall indicate on the duplicate indique sur celle-ci : certificate of qualification that it a) qu’il s’agit d’une copie; (a) is a duplicate; and b) qu’elle ne peut être affichée que dans (b) may be posted only in the plant identified l’installation y désignée. on its face. (5) A duplicate certificate issued under (5) Toute copie de certificat délivrée en vertu du subsection (4) may be posted only in the plant identified paragraphe (4) ne peut être affichée que dans on the duplicate certificate. l’installation qui est désignée sur cette copie. (6) If a duplicate certificate of qualification issued (6) Si une copie de certificat de qualification under subsection (4) is no longer required to be posted délivrée en vertu du paragraphe (4) n’a plus à être under the Act or these regulations, the person named in affichée en vertu de la Loi ou du présent règlement, la the duplicate certificate shall, without delay, return it to personne y nommée doit la retourner immédiatement au the chief inspector. R-078-2013,s.6,16. chef inspecteur. R-078-2013, art. 6(1). 34. If a certificate of qualification is lost or destroyed, 34. À la demande de son titulaire et après le paiement the chief inspector may issue a duplicate certificate on du droit fixé à l’annexe, le chef inspecteur peut délivrer the request of the holder of the certificate of une copie d’un certificat de qualification qui a été perdu qualification and the payment of the fee set out in the ou détruit. Schedule. R-078-2013,s.6(2). 35. (1) A Class 1 operating engineer’s certificate of 35. (1) Tout certificat de qualification de mécanicien qualification entitles the holder to de machines fixes de classe 1 donne droit à son (a) exercise general supervision of and be titulaire : responsible for a first class plant as chief a) d’exercer une surveillance générale et operating engineer and to supervise the d’être responsable d’une installation de shift engineers in that plant; and classe 1, à titre de mécanicien-opérateur (b) operate a first class plant as a shift en chef, et de diriger les mécaniciens de engineer. poste de cette installation; 16 b) d’exploiter une installation de classe 1 à titre de mécanicien de poste. (2) A Class 2 operating engineer’s certificate of (2) Tout certificat de qualification de mécanicien de qualification entitles the holder to machines fixes de classe 2, donne droit à son titulaire : (a) exercise general supervision of and be a) d’exercer une surveillance générale et responsible for a second class plant as d’être responsable d’une installation de chief operating engineer and to supervise classe 2, à titre de mécanicien-opérateur en the shift engineers in that plant; and chef, et de diriger les mécaniciens de poste (b) operate a first class plant as a shift de cette installation; engineer. b) d’exploiter une installation de classe 1 à titre de mécanicien de poste. (3) A Class 3 operating engineer’s certificate of (3) Tout certificat de qualification de mécanicien qualification entitles the holder to de machines fixes de classe 3, donne droit à son (a) exercise general supervision of and be titulaire : responsible for a third class plant as chief a) d’exercer une surveillance générale et operating engineer and to supervise the d’être responsable d’une installation de shift engineers in that plant; classe 3, à titre de mécanicien-opérateur (b) operate a second class plant as shift en chef, et de diriger les mécaniciens de engineer; and poste de cette installation; (c) operate a first class plant as assistant shift b) d’exploiter une installation de classe 2, à engineer under the supervision of the shift titre de mécanicien de poste; engineer of that plant. c) d’exploiter, sous la surveillance du mécanicien de poste, une installation de classe 1 à titre de mécanicien de poste assistant. (4) A Class 4 operating engineer’s certificate of (4) Tout certificat de qualification de mécanicien qualification entitles the holder to de machines fixes de classe 4, donne droit à son (a) exercise general supervision of and be titulaire : responsible for a fourth class plant as a) d’exercer une surveillance générale et chief operating engineer and to supervise d’être responsable d’une installation de the shift engineers in that plant; classe 4, à titre de mécanicien-opérateur (b) operate a third class plant as a shift en chef, et de diriger les mécaniciens de engineer; and poste de cette installation; (c) operate a first or second class plant as an b) d’exploiter une installation de classe 3, à assistant shift engineer under the titre de mécanicien de poste; supervision of the shift engineer of that plant. c) d’exploiter, sous la surveillance du mécanicien de poste, une installation de classe 1 ou 2 à titre de mécanicien de poste assistant. (5) A Class 5 operating engineer’s certificate of (5) Tout certificat de qualification de mécanicien qualification entitles the holder to de machines fixes de classe 5, donne droit à son (a) exercise general supervision of and be titulaire : responsible for a fifth class plant and to a) d’exercer une surveillance générale, d’être supervise the shift engineers in that plant; responsable d’une installation de classe 5 (b) operate a fourth class plant as a shift et de diriger les mécaniciens de poste de engineer; cette installation; (c) operate a third class plant as assistant shift b) d’exploiter une installation de classe 4 à engineer under the supervision of the shift titre de mécanicien de poste; 17 engineer of that plant; and c) d’exploiter, sous la surveillance du (d) assist the assistant shift engineer of a first mécanicien de poste, une installation de or second class plant under the classe 3 à titre de mécanicien de poste supervision of the shift engineer of that assistant; plant. d) d’aider le mécanicien de poste assistant R-076-97,s.6,7; R-078-2013,s.17. d’une installation de classe 1 ou 2, sous la surveillance du mécanicien de poste de cette installation. R-076-97, art. 6 et 7. 36. (1) If the chief operating engineer of a plant is sick 36. (1) Si le mécanicien-opérateur en chef d’une or expects to be absent from the plant for which he or installation est malade ou prévoit être absent de she is responsible, l’installation dont il est responsable : (a) the employer or chief operating engineer a) l’employeur ou le mécanicien-opérateur shall notify the chief inspector of the en chef doit aviser le chef inspecteur de absence or expected absence and of the l’absence effective ou prévue et lui donner name of the person proposed to replace le nom de la personne proposée pour the chief operating engineer; and remplacer le mécanicien-opérateur en (b) the employer may apply to the chief chef; inspector for a temporary certificate of b) l’employeur peut présenter une demande qualification for the person proposed as a au chef inspecteur afin d’obtenir un replacement. certificat de qualification temporaire pour la personne proposée comme remplaçant. (2) If the absence or expected absence referred to (2) Si l’absence effective ou prévue visée au in subsection (1) is greater than 96 hours, the paragraphe (1) excède 96 heures, l’avis d’absence ainsi notification and application referred to in that que la demande de certificat visés au paragraphe (1) subsection must be in writing. sont formulés par écrit. (3) An application referred to in paragraph (1)(b) (3) Toute demande visée à l’alinéa (1)b) comprend must contain a declaration by the employer, or an agent la déclaration de l’employeur ou de son représentant si of the employer if the employer is a corporation, that celui-ci est une personne morale, établissant que la the person proposed as a replacement is, to the best of personne proposée est, au meilleur des connaissances the knowledge of the declarant, capable of acting in the du déclarant, capable d’agir à ce titre et en conformité capacity for which the certificate of qualification is avec le certificat de qualification. requested. (4) The chief inspector may issue a temporary (4) Le chef inspecteur peut délivrer un certificat certificate of qualification to a person proposed as a temporaire de qualification à la personne proposée en replacement if remplacement si : (a) the chief inspector is satisfied the person a) le chef inspecteur estime que la personne has sufficient experience to operate a proposée a suffisamment d’expérience plant of the type or class specified; and pour exploiter une installation du type ou (b) the class of plant is no more than one de la classe spécifiée; grade higher than the class of plant the b) l’installation n’est pas d’une classe person is entitled to operate under his or supérieure à celle que la personne a le her certificate of qualification. droit d’exploiter en vertu de son certificat de qualification. (5) If a temporary certificate of qualification is (5) Si un certificat temporaire de qualifica-tion est issued, the chief inspector délivré, le chef inspecteur : (a) shall specify the date of expiry of the a) précise la date d’expiration du certificat; certificate; and 18 (b) may impose such conditions on the holder b) peut imposer au titulaire du certificat les of the certificate as the chief inspector conditions qu’il estime nécessaires. considers necessary. (6) A temporary certificate of qualification that (6) Un certificat temporaire de qualification qui expires within 96 hours after its issue need not be in prend fin dans les 96 heures de sa délivrance, n’a pas writing. R-078-2013,s.2,6(1). besoin d’être fait par écrit. R-078-2013, art. 2, 6(1). 37. (1) To qualify to take an examination for a Class 37. (1) Pour être admissible à l’examen visant 1 operating engineer’s certificate of qualification, a l’obtention d’un certificat de qualification de mécanicien candidate must de machines fixes de classe 1, le candidat doit : (a) hold a Class 2 operating engineer’s a) détenir un certificat de qualification de certificate of qualification; and mécanicien de machines fixes de classe 2; (b) provide evidence satisfactory to the chief b) fournir, à la satisfaction du chef inspecteur, inspector of employment for a period of la preuve d’un emploi d’une période de (i) 30 months as chief operating soit : engineer in a second class plant, (i) 30 mois à titre de mécanicien- (ii) 30 months as shift engineer in a first opérateur en chef d’une installation de class plant, classe 2, (iii) 45 months as assistant shift engineer (ii) 30 mois à titre de mécanicien de poste in a first class plant, d’une installation de classe 1, (iv) one-half the number of months in a (iii) 45 mois à titre de mécanicien de position specified in subparagraph poste-assistant d’une installation de (i), (ii) or (iii) and, in addition, classe 1, employment for a period of 15 (iv) la moitié du nombre de mois dans une months in a compressor plant in an fonction mentionnée aux sous- operating capacity approved by the alinéas (i), (ii) ou (iii) et, en plus, un chief inspector, emploi d’une durée de 15 mois dans (v) 15 months in a position specified in une station de compression dans une subparagraph (i), (ii) or (iii) and, in fonction d’opérateur autorisée par le addition, that the candidate holds a chef inspecteur, degree in mechanical engineering (v) 15 mois dans une fonction mention- from a university approved by the née aux sous-alinéas (i), (ii) ou (iii) et, chief inspector or has, in the opinion en plus, qu’il détienne un baccalauréat of the chief inspector, the equivalent en génie mécanique délivré par une of such a degree, or université agréée par le chef (vi) one-half the number of months in a inspecteur ou qu’il détienne, selon position specified in subparagraph l’avis de celui-ci, l’équivalent d’un tel (i), (ii) or (iii) and, in addition, diplôme, employment for a period of 36 (vi) la moitié du mombre de mois dans months in a supervisory capacity une fonction mentionnée aux sous- satisfactory to the chief inspector in alinéas (i), (ii), ou (iii) et , en plus, un relation to the design, construction, emploi d’une période de 36 mois dans installation, repair, maintenance or une fonction de surveillance operation of regulated equipment. approuvée par le chef inspecteur relativement à la conception, la construction, le montage, la réparation, l’entretien ou le fonctionnement du matériel réglementé. 19 (2) The chief inspector may grant 12 months credit (2) Un crédit de 12 mois tenant lieu de l’emploi in lieu of the employment specified in mentionné aux sous-alinéas (1)b)(i), (ii) ou (iii), peut subparagraph (1)(b)(i), (ii) or (iii) on the candidate’s être alloué à un candidat qui a réussit un cours de génie successful completion of a course in power engineering énergétique, jugé satisfaisant par le chef inspecteur, et that is satisfactory to the chief inspector and that leads ceci permet au candidat d’écrire l’examen pour un to a Class 1 operating engineer’s certificate of certificat de qualification de mécanicien de machines qualification examination. fixes de classe 1. (3) The chief inspector may grant 12 months credit (3) Un crédit de 12 mois tenant lieu de l’emploi in lieu of the compressor plant experience specified in dans une station de compression mentionné aux sous- subparagraph (1)(b)(iv) on the candidate’s successful alinéa (1)b)(iv), peut être alloué à un candidat qui a completion of a course in power engineering that is réussit un cours de génie énergétique, jugé satisfaisant satisfactory to the chief inspector and that leads to a par le chef inspecteur, et ceci permet au candidat Class 1 operating engineer’s certificate of qualification d’écrire l’examen pour un certificat de qualification de examination. mécanicien de machines fixes de classe 1. (4) The examination for a Class 1 operating (4) L’examen pour un certificat de qualification de engineer’s certificate of qualification must be divided mécanicien de machines fixes de classe 1 doit être into two parts, lettered A and B, and a candidate may divisé en deux parties, A et B, et le candidat peut soit : (a) write any one or all papers for Part A at a a) remettre, lors de l’examen prévu, un seul scheduled examination after obtaining a ou tous les travaux de la partie A, après Class 2 operating engineer’s certificate of avoir obtenu le certificat de qualification qualification; de mécanicien de machines fixes de (b) write any one or all papers for Part B after classe 2; successfully completing the papers for b) remettre, après avoir réussi les travaux de Part A, after the qualifying experience has la partie A, un seul ou tous les travaux de been obtained as specified in subsection la partie B après que l’expérience requise (1); or ait été obtenue tel qu’exigé au (c) write the papers for both parts at the same paragraphe (1); sitting, after the qualifying experience has c) remettre tous les travaux des deux parties been obtained as specified in subsection lors d’une même séance d’examen, après (1). que l’expérience requise ait été obtenue tel qu’exigé au paragraphe (1). (5) The examination must consist of questions (5) L’examen doit comporter des questions relating to the subjects contained in the current relatives aux sujets figurant au plan de cours en usage reference syllabus as adopted by the chief inspector for tel qu’il a été établi par le chef inspecteur pour the Class 1 operating engineer’s certificate of l’obtention du certificat de qualification de mécanicien qualification examination. de machines fixes de classe 1. (6) To obtain a pass and a certificate of (6) Pour obtenir la mention «réussite» et un qualification, a candidate must obtain at least 65% of certificat de qualification, le candidat doit obtenir la the marks for each paper. R-060-2005,s.5; note de 65% ou plus pour chaque travail. R-060-2005, R-078-2013,s.18(1),20,21. art. 5; R-078-2013, art. 19, 20, 21. 38. (1) To qualify to take an examination for a Class 38. (1) Pour être admissible à l’examen visant à 2 operating engineer’s certificate of qualification, a l’obtention d’un certificat de qualification de candidate must mécanicien de machines fixes de classe 2, le candidat (a) hold a Class 3 operating engineer’s doit : certificate of qualification; and a) détenir un certificat de qualification de (b) provide evidence satisfactory to the chief mécanicien de machines fixes de classe 3; inspector of employment for a period of b) fournir à la satisfaction du chef inspecteur (i) 24 months as a chief operating la preuve d’un emploi d’une période de 20 engineer of a third class high soit : pressure plant, (i) 24 mois à titre de mécanicien- (ii) 24 months as a shift engineer in a opérateur en chef d’une installation à second class plant, haute pression de classe 3, (iii) 36 months as a shift engineer in a (ii) 24 mois à titre de mécanicien de third class high pressure plant, poste dans une installation de (iv) 24 months as an assistant shift classe 2, engineer in a first class plant, (iii) 36 mois à titre de mécanicien de (v) one-half the number of months in a poste dans une installation à haute position specified in subparagraph pression de classe 3, (i), (ii), (iii) or (iv) and, in addition, (iv) 24 mois à titre de mécanicien de employment for a period of 12 poste-assistant dans une installation months in a compressor plant in an de classe 1, operating capacity satisfactory to the (v) la moitié du nombre de mois dans chief inspector, une fonction mentionnée aux sous- (vi) 12 months in a position specified in alinéas (i), (ii), (iii) ou (iv) et, en subparagraph (i), (ii), (iii) or (iv) plus, un emploi d’une durée de 12 and, in addition, that the candidate mois dans une station de holds a degree in mechanical compression dans une fonction jugée engineering from a university satisfaisante par le chef inspecteur, approved by the chief inspector or (vi) 12 mois dans une fonction has, in the opinion of the chief mentionnée aux sous-alinéas (i), (ii), inspector, the equivalent of such a (iii) ou (iv) et, en plus, qu’il détienne degree, or un baccalauréat en génie mécanique (vii) one-half the number of months in a délivré par une université agréée par position specified in subparagraph le chef inspecteur ou qu’il détienne, (i), (ii), (iii) or (iv) and, in addition, selon l’avis de celui-ci, l’équivalent employment for a period of 24 d’un tel diplôme, months in a supervisory capacity (vii) la moitié du nombre de mois dans satisfactory to the chief inspector in une fonction mentionnée aux sous- relation to the design, construction, alinéas (i), (ii), (iii) ou (iv) et, en installation, repair, maintenance or plus, un emploi d’une durée de 24 operation of regulated equipment. mois dans une fonction de surveillance jugée satisfaisante par le chef inspecteur relativement à la conception, la construction, la réparation, le montage, l’entretien ou le fonctionnement du matériel réglementé. (2) The chief inspector may grant nine months (2) Un crédit de neuf mois tenant lieu de l’emploi credit in lieu of the employment specified in mentionné aux sous-alinéas (1)b)(i), (ii), (iii), ou (iv) subparagraph (1)(b)(i), (ii), (iii) or (iv) on the peut être alloué à un candidat qui a réussi un cours de candidate’s successful completion of a course in power génie énergétique, jugé satisfaisant par le chef engineering that is satisfactory to the chief inspector inspecteur, et ceci permet au candidat d’écrire l’examen and that leads to a Class 2 operating engineer’s pour un certificat de qualification de mécanicien de certificate of qualification examination. machines fixes de class 2. (3) A candidate who is the holder of a diploma (3) Le candidat qui, après avoir suivi à plein temps issued by an educational institution after the candidate un cours de deux ans en génie énergétique jugé completed a two year day course in power engineering satisfaisant par le chef inspecteur, est titulaire d’un satisfactory to the chief inspector and who is the holder diplôme délivré par un établissement d’enseignement et of a Class 3 operating engineer’s certificate of qui est titulaire d’un certificat de qualification de 21 qualification, is qualified to take a Class 2 operating mécanicien de machines fixes de classe 3, est engineer’s certificate of qualification examination after admissible à l’examen de qualification de mécanicien obtaining one-half the qualifying experience specified de machines fixes de classe 2, après avoir obtenu la in subparagraph (1)(b)(i), (ii), (iii) or (iv). moitié de l’expérience exigée en vertu des sous- alinéas (1)b)(i), (ii), (iii) ou (iv). (4) The chief inspector may grant nine months (4) Un crédit de neuf mois tenant lieu de credit in lieu of the compressor plant experience l’expérience dans une station de compression specified in subparagraph (1)(b)(v) on the candidate’s mentionnée aux sous-alinéas (1)b)(v), peut être alloué successful completion of a course in power engineering à un candidat qui a réussi un cours de génie that is satisfactory to the chief inspector and that leads énergétique, jugé satisfaisant par le chef inspecteur, et to a Class 2 operating engineer’s certificate of ceci permet au candidat d’écrire l’examen pour un qualification examination. certificat de qualification de mécanicien de machines fixes de classe 2. (5) The examination for a Class 2 operating (5) L’examen pour un certificat de qualification de engineer’s certificate of qualification must be divided mécanicien de machines fixes de classe 2 doit se diviser into two parts, lettered A and B, and a candidate may en deux parties, A et B, et le candidat peut soit : write a) remettre, lors de l’examen prévu, un seul (a) any one or all papers for Part A at a ou tous les travaux de la partie A, après scheduled examination after obtaining a avoir obtenu le certificat de qualification Class 3 operating engineer’s certificate of de mécanicien de machines fixes de qualification; classe 3; (b) any one or all papers for Part B after b) remettre, après avoir réussi les travaux de successfully completing the papers for la partie A, un seul ou tous les travaux de Part A, after the qualifying experience has la partie B après que l’expérience requise been obtained as specified in ait été obtenue tel qu’exigé au subsection (1); or paragraphe (1); (c) all the papers for both parts at the same c) remettre tous les travaux pour les deux sitting, after the qualifying experience has parties lors de la même séance d’examen, been obtained as specified in après que l’expérience requise ait été subsection (1). obtenue tel que mentionné au paragraphe (1). (6) The examination must consist of questions (6) L’examen doit comporter des questions relating to the subjects contained in the reference relatives aux sujets figurant au plan de cours en usage syllabus as adopted by the chief inspector for the tel qu’il a été établi par le chef inspecteur pour Class 2 operating engineer’s certificate of qualification l’obtention du certificat de qualification de mécanicien examination. de machines fixes de classe 2. (7) To obtain a pass and a certificate of (7) Pour obtenir la mention «réussite» et un qualification, a candidate must obtain at least 65% of certificat de qualification, le candidat doit obtenir la the marks for each paper. R-060-2005,s.6; note de 65% ou plus pour chaque travail. R-060-2005, R-078-2013,s.18(1),21,22. art. 6; R-078-2013, art. 19, 21, 22. 39. (1) To qualify to take an examination for a Class 39. (1) Pour être admissible à l’examen visant 3 operating engineer’s certificate of qualification, a l’obtention d’un certificat de qualification de candidate must mécanicien de machines fixes de classe 3, le candidat (a) hold a Class 4 operating engineer’s doit : certificate of qualification; and a) détenir un certificat de qualification de (b) provide evidence satisfactory to the chief mécanicien de machines fixes de classe 4; inspector of employment for a period of b) fournir la preuve d’un emploi qui satisfait (i) 12 months as chief operating le chef inspecteur d’une période de soit : 22 engineer in a fourth class plant, (i) 12 mois à titre de mécanicien- (ii) 12 months as shift engineer in a third opérateur en chef dans une class plant, installation de classe 4, (iii) 24 months, in an operating capacity (ii) 12 mois à titre de mécanicien de satisfactory to the chief inspector, in poste dans une installation de the operation of a first, second or classe 3, third class plant, (iii) 24 mois dans le fonctionnement (iv) one-third the number of months in a d’une installation de classe 1, 2 ou 3 position specified in dans une fonction d’opérateur que le subparagraph (i), (ii) or (iii) and, in chef inspecteur estime satisfaisante, addition, employment for a period of (iv) un tiers du nombre de mois dans une eight months in a compressor plant in fonction mentionnée aux sous- an operating capacity satisfactory to alinéas (i), (ii) ou (iii) et, en plus, un the chief inspector, emploi d’une durée de huit mois dans (v) one-half the number of months in a une station de compression dans une position specified in fonction d’opérateur jugée subparagraph (i), (ii) or (iii) and in satisfaisante par le chef inspecteur, addition that the candidate holds a (v) la moitié du nombre de mois dans degree in mechanical engineering une fonction mentionnée aux from a university satisfactory to the sous-alinéas (i), (ii) ou (iii) et, chief inspector or has, in the opinion détenir un baccalauréat en génie of the chief inspector, the equivalent mécanique délivré par une université of such a degree, jugée satisfaisante par le chef (vi) one-third the number of months in a inspecteur ou détenir, de l’avis du position specified in chef inspecteur, l’équivalent d’un tel subparagraph (i), (ii) or (iii) and, in diplôme, addition, employment for a period of (vi) un tiers du nombre de mois dans une two months in a compressor plant in fonction mentionnée aux sous an operating capacity satisfactory to alinéas (i), (ii) ou (iii) et, en plus, un the chief inspector during which emploi d’une durée de deux mois periods the candidate held a degree dans une station de compression dans in mechanical engineering from a une fonction d’opérateur jugée university approved by the chief satisfaisante par le chef inspecteur inspector or had, in the opinion of tout en étant titulaire d’un the chief inspector, the equivalent of baccalauréat en génie mécanique such a degree, or délivré par une université agréée par (vii) one-half the number of months in a le chef inspecteur ou, selon l’avis de position specified in celui-ci, de l’équivalent d’un tel subparagraph (i), (ii) or (iii) and, in diplôme, addition, employment for a period of (vii) la moitié du nombre de mois dans 12 months in a capacity satisfactory une fonction mentionnée aux sous- to the chief inspector on the design, alinéas (i), (ii) ou (iii) et, en plus, un construction, installation, repair, emploi d’une durée de 12 mois dans maintenance or operation of une fonction jugée satisfaisante par regulated equipment. le chef inspecteur relative à la conception, à la construction, au montage, à la réparation, à l’entretien ou au fonctionnement du matériel réglementé. (2) The chief inspector may grant six months (2) Un crédit de six mois tenant lieu de l’emploi credit in lieu of the employment specified in mentionné aux sous-alinéas (1)b)(i), (ii) ou (iii) peut subparagraph (1)(b)(i), (ii) or (iii) on the candidate’s être alloué à un candidat qui a réussi un cours de génie 23 successful completion of a course in power engineering énergétique, jugé satisfaisant par le chef inspecteur, et that is satisfactory to the chief inspector and that leads ceci permet au candidat d’écrire l’examen pour un to a Class 3 operating engineer’s certificate of certificat de qualification de mécanicien de machines qualification examination. fixes de classe 3. (3) The chief inspector may grant six months (3) Un crédit de six mois tenant lieu de credit in lieu of the compressor plant experience l’expérience dans une station de compression, specified in subparagraph (1)(b)(v) on the candidate’s mentionnée au sous-alinéa (1)b)(v), peut être alloué à successful completion of a course in power engineering un candidat qui a réussi un cours de génie énergétique, that is satisfactory to the chief inspector and that leads jugé satisfaisant par le chef inspecteur, et ceci permet to a Class 3 operating engineer’s certificate of au candidat d’écrire l’examen pour un certificat de qualification examination. qualification de mécanicien de machines fixes de classe 3. (4) The examination for a Class 3 operating (4) L’examen pour un certificat de qualification de engineer’s certificate of qualification must be divided mécanicien de machines fixes de classe 3 doit se diviser into two parts, lettered A and B, and a candidate may en deux parties, A et B, et le candidat peut soit : write a) remettre, lors de l’examen prévu, un seul (a) any one or all papers for Part A at a ou tous les travaux de la partie A, après scheduled examination after obtaining a avoir obtenu le certificat de qualification Class 4 operating engineer’s certificate of de mécanicien de machines fixes de qualification; classe 4; (b) any one or all papers for Part B after b) remettre, après avoir réussi les travaux de successfully completing the papers for la partie A, un seul ou tous les travaux de Part A, after the qualifying experience has la partie B après que l’expérience requise been obtained as specified in ait été obtenue tel qu’exigé au subsection (1); or paragraphe (1); (c) all the papers for both parts at the same c) remettre tous les travaux pour les deux sitting, after the qualifying experience has parties lors de la même séance d’examen, been obtained as specified in après que l’expérience requise ait été subsection (1). obtenue tel que mentionné au paragaphe (1). (5) The examination must consist of questions (5) L’examen doit comporter des questions relating to the subjects contained in the current relatives aux sujets figurant au plan de cours en usage reference syllabus as adopted by the chief inspector for tel qu’il a été établi par le chef inspecteur, pour the Class 3 operating engineer’s certificate of l’obtention du certificat de qualification de mécanicien qualification examination. de machines fixes de classe 3. (6) To obtain a pass and a certificate of (6) Pour obtenir la mention «réussite» et un qualification, a candidate must obtain at least 65% of certificat de qualification, le candidat doit obtenir la note the marks for each paper. R-076-97,s.8,9; de 65% ou plus pour chaque travail. R-076-97, art. 8 et R-060-2005,s.7; R-078-2013,s.18(1),21,23. 9; R-060-2005, art. 6; R-078-2013, art. 19, 21, 23. 40. (1) To qualify to take an examination for a Class 40. (1) Pour être admissible à l’examen visant 4 operating engineer’s certificate of qualification, a l’obtention d’un certificat de qualification de candidate must provide evidence satisfactory to the mécanicien de machines fixes de classe 4, le candidat chief inspector of employment for a period of doit fournir la preuve que le chef inspecteur estime (a) 12 months assisting in the operation of a satisfaisante d’une période d’emploi de : high pressure plant having a generating a) 12 mois à aider au fonctionnement d’une capacity exceeding 500 kW in an installation à haute pression d’une operating capacity satisfactory to the chief capacité de production supérieure à inspector; 500 Kw dans une fonction d’opérateur que 24 (b) 12 months as a chief operating engineer in le chef inspecteur estime satisfaisante; a fifth class plant; b) 12 mois à titre de mécanicien de machine (c) 24 months as a shift engineer in a low fixe dans une installation de classe 5; pressure plant; c) 24 mois à titre de mécanicien de poste (d) six months in a high pressure plant of any dans une installation à basse pression; class in an operating capacity satisfactory d) six mois dans une installation à haute to the chief inspector and, in addition, that pression de toute classe dans une fonction the candidate holds a degree in d’opérateur que le chef inspecteur estime mechanical engineering from a university satisfaisant; de plus, il doit détenir un satisfactory to the chief inspector or has, baccalauréat en génie mécanique délivré in the opinion of the chief inspector, the par une université jugée satisfaisante par equivalent of such a degree; le chef inspecteur; (e) six months in a high pressure plant of any e) six mois dans une installation à haute class in an operating capacity satisfactory pression de toute classe dans une fonction to the chief inspector and, in addition, d’opérateur que le chef inspecteur estime employment for a period of 12 months in satisfaisante; de plus, il doit avoir exercé the design, construction, installation, un emploi d’une durée de 12 mois dans repair, maintenance or operation of une fonction d’opérateur que le chef regulated equipment; or inspecteur estime satisfaisante relative à la (f) one-half the number of months in a conception, à la construction, au montage, position specified in paragraph (a), (b), à la réparation, à l’entretien ou au or (c) and, in addition, employment for a fonctionnement du matériel réglementé; period of six months in a compressor plant f) la moitié du nombre de mois dans une in an operating capacity satisfactory to the fonction mentionnée aux alinéas a), b) ou chief inspector. c); de plus, il doit avoir exercé un emploi d’une durée de six mois dans une fonction d’opérateur que le chef inspecteur estime satisfaisante dans une station de compression. (2) The chief inspector may grant six months (2) Un crédit de six mois tenant lieu de la période credit in lieu of the employment specified in d’emploi mentionnée aux alinéas (1)a), b) ou c) ou de paragraph (1)(a), (b) or (c) or the 12 months la période d’emploi de 12 mois mentionnée à l’alinéa e) employment specified in paragraph (e) on the peut être alloué au candidat qui a réussi un cours de candidate’s successful completion of a course in power génie énergétique, que le chef inspecteur estime engineering that is satisfactory to the chief inspector satisfaisant, et ceci permet au candidat d’écrire and that leads to a Class 4 operating engineer’s l’examen pour un certificat de qualification de certificate of qualification examination. mécanicien de machines fixes de classe 4. (3) Repealed, R-076-97,s.11. (3) Abrogé, R-076-97, art. 11. (4) The examination for a Class 4 operating (4) L’examen pour un certificat de qualification de engineer’s certificate of qualification must be divided mécanicien de machines fixes de classe 4 doit se diviser into two parts, lettered A and B, and a candidate may en deux parties, A et B, et le candidat peut soit : write (a) Part A at a scheduled examination if he or a) remettre, lors de l’examen prévu, she is employed in the operation and l’examen de la partie A, s’il est employé maintenance of a boiler plant to which the au fonctionnement et à l’entretien d’une Act applies; chaudière à laquelle la Loi s’applique; (b) Part B after successfully completing Part b) remettre, après avoir réussi la partie A, A, after the qualifying experience has l’examen de la partie B après que been obtained as specified in l’expérience requise ait été obtenue tel subsection (1); or qu’exigé au paragraphe (1); 25 (c) both parts at the same sitting, after the c) remettre les deux parties, lors d’une même qualifying experience has been obtained séance d’examen, après que l’expérience as specified in subsection (1). requise ait été obtenue tel que mentionné au paragraphe (1). (5) The examination must consist of questions (5) L’examen doit comporter des questions relating to the subjects contained in the current relatives aux sujets figurant au plan de cours en usage, reference syllabus as adopted by the chief inspector for tel qu’il a été établi par le chef inspecteur, pour the Class 4 operating engineer’s certificate of l’examen visant l’obtention du certificat de qualification qualification examination. de mécanicien de machines fixes de classe 4. (6) To obtain a pass and a certificate of (6) Pour obtenir la mention «réussite» et un qualification, a candidate must obtain at least 65% of certificat de qualification, le candidat doit obtenir la the marks for each paper. R-076-97,s.10, 11,12; note de 65% ou plus pour chaque travail. R-076-97, R-060-2005,s.8; R-078-2013,s.21,24. art. 10, 11 et 12; R-060-2005, art. 8; R-078-2013, art. 19, 21, 24. 41. (1) To qualify to take an examination for a Class 41. (1) Pour être admissible à l’examen visant à 5 operating engineer’s certificate of qualification, a l’obtention d’un certificat de qualification de candidate must provide evidence satisfactory to the mécanicien de machines fixes de classe 5, le candidat chief inspector that the candidate has been employed doit fournir, à la satisfaction du chef inspecteur, la for a period of 12 months in the operation and preuve qu’il a été employé pour entretenir et exploiter maintenance of a boiler plant to which the Act applies. une chaudière visée par la Loi pendant une période de 12 mois.
Part document.segment-3
Boilers Pressure Vessels Regulation 1 — segment 3
- document.segment-3 Verify source ↗
Boilers Pressure Vessels Regulation 1 — segment 3
This part sets examination, qualification, and welding-card rules: candidates must apply on time, take exams as directed, meet pass marks, and pay required fees; the chief inspector and inspectors have specified powers over credits, testing, issuing certificates, and requalification.
(2) The chief inspector may grant six months (2) Un crédit de six mois tenant lieu de l’emploi credit in lieu of the employment specified in mentionné au paragraphe (1) peut être alloué au subsection (1) on the candidate’s successful completion candidat qui a réussi un cours jugé satisfaisant par le of a course that is satisfactory to the chief inspector and chef inspecteur, et ceci permet au candidat d’écrire that leads to a Class 5 operating engineer’s certificate of l’examen pour un certificat de qualification de qualification examination. mécanicien de machines fixes de classe 5. (3) The candidate shall write all papers for the (3) Le candidat doit passer tous ses examens lors examination at one sitting. d’une même séance. (4) The examination for a Class 5 operating (4) L’examen pour un certificat de qualification de engineer’s certificate of qualification must consist of mécanicien de machines fixes de classe 5 doit questions relating to the subjects contained in the comporter des questions relatives aux sujets figurant current reference syllabus established by the chief dans le plan de cours en usage établi par le chef inspector. inspecteur. (5) To obtain a pass and a certificate of (5) Pour obtenir la mention «réussite» et un qualification, a candidate must obtain at least 65% of certificat de qualification, le candidat doit obtenir la the marks for each paper. R-060-2005,s.9; note de 65% ou plus pour chaque travail. R-078-2013,s.25. R-060-2005, art. 9; R-078-2013, art. 25. (6) Repealed, R-060-2005,s.9. (6) Abrogé, R-060-2005, art. 9. 42. (1) Subject to subsection (2), the chief inspector 42. (1) Sous réserve du paragraphe (2), le chef may grant credit to a person who has passed courses in inspecteur peut allouer, pour compenser le manque power engineering that the chief inspector considers d’expérience pratique, des crédits à une personne qui a satisfactory in lieu of practical experience. réussi les cours en génie énergétique, jugés satisfaisant par le chef inspecteur. 26 (2) If a person is granted credit for a course for (2) Les crédits alloués au candidat afin de le one level of examination, the chief inspector shall not rendre admissible à un certain niveau d’examen ne grant credit to the person for that course to qualify for peuvent pas, pour le même cours, lui être alloués de a higher level of examination. R-078-2013,s.6(2). nouveau par le chef inspecteur pour être admissible à un examen de niveau de supérieur. 43. (1) If a candidate has experience made up in part 43. (1) Le chef inspecteur peut évaluer une expérience as chief operating engineer, shift engineer or assistant de travail lorsque le candidat l’a acquise en partie shift engineer or any other experience, the chief notamment à titre de mécanicien-opérateur en chef, inspector may evaluate that experience. mécanicien de poste, mécanicien de poste-assistant. (2) If a candidate provides proof of experience (2) Le chef inspecteur peut allouer des crédits with regulated equipment, which experience is tenant lieu de l’expérience prévue lorsqu’un candidat acceptable to the chief inspector and other than that fournit la preuve de son expérience de travail avec du specified in subsections 37(1), 38(1) and 39(1), the matériel réglementé, laquelle est jugée acceptable selon chief inspector may grant credit in lieu of the specified le chef inspecteur et autre que celle mentionnée aux experience. paragraphes 37(1), 38(1) et 39(1). (3) If a compressor plant is in operation for only (3) Si une station de compression n’est exploitée part of a year and the operating engineer is retained for qu’une partie de l’année et que les services d’un the non-operational period and is employed on plant mécanicien de machines fixes sont retenus pour maintenance, the chief inspector may grant credit of s’occuper de l’entretien de l’installation pendant la two-thirds of the maintenance time towards experience période d’inactivité, le chef inspecteur peut créditer au required for an examination. deux-tiers le temps consacré à l’entretien à titre d’expérience requise pour permettre l’admissibilité à un examen de niveau supérieur. (4) If a person is granted credit for practical (4) Si une personne obtient pour son expérience experience for a certain operating engineer’s pratique, un crédit qui lui permet d’être admissible à un examination, the chief inspector shall not grant credit to examen de mécanicien de machines fixes, le chef the person for that experience to qualify for a higher inspecteur ne doit pas, pour cette même expérience, level of examination. R-078-2013,s.6,18(2). allouer de nouveau un crédit à cette personne dans le but de la rendre admissible à un examen de niveau supérieur. R-078-2013, art. 6(1). 44. (1) The chief inspector may, on application, issue 44. (1) Le chef inspecteur peut, sur demande, délivrer a certificate of qualification to a person who holds a un certificat de qualification à une personne qui est certificate of qualification from a jurisdiction outside titulaire d’un certificat de qualification d’une juridiction the Northwest Territories, if autre que les Territoires du Nord-Ouest, si les (a) the chief inspector is of the opinion that conditions suivantes sont réunies : the applicant’s certificate is equivalent to a) le chef inspecteur est d’avis que le a certificate of qualification issued under certificat du demandeur est équivalent à these regulations; and un certificat de qualification délivré en (b) the application is accompanied by the fee vertu du présent règlement; set out in the Schedule. b) la demande est accompagnée du droit fixé à l’annexe. (2) A certificate of qualification issued under this (2) Tout certificat de qualification délivré en vertu section may be issued subject to such conditions as the du présent article peut être assorti des conditions que le chief inspector considers necessary. chef inspecteur juge nécessaires. 27 (3) The chief inspector shall not issue a certificate (3) Le chef inspecteur ne délivre pas de certificat of qualification under this section until the chief de qualification en vertu du présent article tant qu’il inspector is satisfied as to the applicant’s identity, n’est pas convaincu de l’identité du demandeur, de son experience and qualifications and, for that purpose, may degré d’expérience et de ses compétences et, à cette fin, require such evidence as the chief inspector considers peut exiger toute preuve qu’il juge nécessaire. necessary. (4) A candidate from a jurisdiction outside the (4) Tout candidat d’une juridiction autre que les Northwest Territories who has passed any paper of an Territoires du Nord-Ouest, qui a reçu la mention operating engineer’s examination in that jurisdiction «réussite» pour un travail remis lors d’un examen de may be given credit by the chief inspector for having mécanicien de machines fixes de cette juridiction, peut passed that paper. R-078-2013,s.6(2),8(2); recevoir des crédits du chef inspecteur pour avoir réussi R-019-2016,s.6. ce travail d’examen. R-019-2016, art. 6. 45. (1) At the discretion of the chief inspector, a non- 45. (1) Le chef inspecteur peut, à sa discrétion, standardized certificate of a class determined délivrer un certificat de non-standardisation d’une appropriate by the chief inspector may be issued by the classe qu’il juge adéquate, à la personne qui : chief inspector to a person who a) est titulaire d’un certificat de non- (a) holds a valid non-standardized certificate standardisation valide à titre de as an operating engineer that is issued by mécanicien de machines fixes délivré soit the Government of Canada, the par le gouvernement fédéral, le government of a province or another gouvernement d’une province ou d’un territory or a competent authority in any autre territoire, soit par une autorité other jurisdiction; and compétente de toute autre juridiction; (b) makes application for a non-standardized b) présente une demande de certificat, certificate accompanied by evidence accompagnée d’une preuve des satisfactory to the chief inspector of the compétences du demandeur et de son applicant’s qualifications and identity. identité qui satisfait le chef inspecteur. (2) An application made under paragraph (1)(b) (2) Toute demande présentée en vertu de must be accompanied by the fee set out in the Schedule. l’alinéa (1)b) est accompagnée du droit fixé à l’annexe. R-078-2013,s.7. R-078-2013, art. 7. 46. (1) A candidate for examination shall apply to 46. (1) Pour se présenter à l’examen, tout candidat write an examination in the approved form at least 21 présente, une demande selon la formule approuvée au days before the date of examination. moins 21 jours avant la date de l’examen. (2) An application for examination must be (2) La demande doit être présentée pour agrément submitted for approval to the chief inspector for the du chef inspecteur, et accompagnée : examination to be written together with a) des photocopies des références ou des (a) photocopies of the references or of written déclarations écrites visées au statements referred to in subsection (4); paragraphe (4); (b) the fee set out in the Schedule; and b) du droit fixé à l’annexe; (c) where educational qualifications are c) lorsqu’ils sont exigés, des documents required, documents in support of the attestant de la formation académique du candidate’s educational qualifications. candidat. (3) The chief inspector shall return any original (3) Le chef inspecteur retourne tous les originaux document to the candidate after verification. des documents au candidat après vérification. (4) The qualifications of a candidate relating to (4) Les qualifications d’un candidat concernant plant operation, engineering experience, ability and l’exploitation d’une installation, son expérience à titre general conduct may be proved by references signed by de mécanicien, ses compétences ainsi que sa conduite 28 the owner or chief operating engineer of the plant where en général peuvent être confirmées par des lettres de the candidate was or is employed, but if such references référence signées par le propriétaire ou le mécanicien- are not available, the chief inspector may, in lieu of opérateur en chef de l’installation dans laquelle le references, accept a written statement made by a person candidat a travaillé, ou travaille encore. Toutefois, si who has personal knowledge of the facts to be de telles références ne sont pas disponibles, le chef established. inspecteur peut accepter à leur place une déclaration écrite, faite par une personne qui a une connaissance personnelle des faits à établir. (5) Educational qualifications must be confirmed (5) La formation académique doit être attestée par by documents issued by the institution from which the les documents émis par l’établissement où le candidat candidate received training. a reçu sa formation. 47. (1) A candidate for examination shall appear at 47. (1) Tout candidat à l’examen se présente au lieu et such place and time as the chief inspector may direct. à l’heure que lui indique le chef inspecteur. (2) An examination must be given under the (2) Tout examen est passé sous la surveillance du direction of the chief inspector. chef inspecteur. 48. (1) The inspector conducting an examination 48. (1) L’inspecteur qui fait passer un examen en vertu under these regulations may declare a candidate to have du présent règlement peut déclarer qu’un candidat à failed the examination if échoué à cet examen soit : (a) formulas or other information have been a) lorsque des formules ou autres added to or inserted without the approval renseignements ont été, sans l’agrément or authorization of the chief inspector into ou l’autorisation du chef inspecteur, a published text of a book, table, ajoutés ou insérés au texte publié d’un regulation, code or standard that is taken livre, tableau, règlement, code ou de into the examination room; normes qui est apporté dans la salle (b) the candidate looks at or refers to material d’examen; during the examination that is not allowed b) lorsque, pendant l’examen, le candidat into the examination room by the chief regarde ou se réfère à du matériel qui n’est inspector; pas autorisé dans la salle d’examen par le (c) the candidate removes or attempts to chef inspecteur; remove a question or part of a question c) lorsque le candidat sort ou tente de sortir from an examination room; une question ou une partie de question de (d) the candidate copies from another la salle d’examen; candidate; or d) lorsque le candidat copie sur un autre (e) the candidate communicates with another candidat; candidate in any manner during the e) lorsque le candidat communique avec un examination. autre candidat de quelque manière que ce soit pendant la durée de l’examen. (2) A candidate who has been declared to have (2) Le candidat qui a échoué à l’examen en vertu failed an examination under subsection (1) may be du paragraphe (1) peut se voir exclu, par le chef disqualified by the chief inspector from writing a inspecteur, des examens à venir pendant une période further examination for a period not exceeding 12 maximale de 12 mois suivant la date de l’examen months after the date of examination. échoué. 49. Each paper of an examination must be marked by 49. Chaque travail remis lors de l’examen est corrigé an inspector. par un inspecteur. 29 50. A person who receives or acquires a certificate of 50. Toute personne qui reçoit ou obtient un certificat qualification issued under these regulations, other than de qualification délivré en vertu du présent règlement, the person whose name appears on the certificate, shall sans être la personne dont le nom apparaît sur ce send the certificate of qualification to the chief certificat, doit remettre le certificat de qualification au inspector. chef inspecteur. 51. (1) Subject to the discretion of the chief inspector, 51. (1) Sous réserve de l’appréciation du chef a candidate who fails an examination may not attempt inspecteur, tout candidat qui échoue à un examen ne the examination again until he or she provides evidence peut se représenter avant de fournir la preuve, jugée satisfactory to the chief inspector of additional satisfaisante au chef inspecteur, d’une expérience experience of not less than supplémentaire d’au moins : (a) 30 days, if the candidate has failed the a) 30 jours, si le candidat a échoué à examination once or twice; or l’examen à une ou deux reprises; (b) three months, if the candidate has failed b) trois mois, si le candidat a échoué à the examination more than twice. l’examen à plus de deux reprises. (2) The chief inspector may dispose of a paper (2) Le chef inspecteur peut jeter une copie written by a candidate for an examination on the expiry d’examen dans un délai de 30 jours suivant la date à of 30 days after the candidate has been notified that he laquelle le candidat a été avisé qu’il a, selon le cas, or she passed the paper or failed the paper, as the case obtenu la mention «réussite» ou «échec». R-078-2013, may be. R-078-2013,s.2,18(2). art. 2. PART III PARTIE III QUALIFICATIONS, EXAMINATIONS AND QUALIFICATIONS, EXAMENS ET CERTIFICATION OF WELDING OPERATORS DÉLIVRANCE DES CERTIFICATS POUR LES SOUDEURS QUALIFIÉS 52. In this Part, "Section IX of the ASME Boilers and 52. Dans la présente partie, la «Partie IX du code Pressure Vessels Code" means the code referred to in ASME sur les chaudières et appareils à pression» subparagraph 3(k)(xiv) as amended from time to time. s’entend du code mentionné au sous-alinéa 3k)(xiv) avec ses modifications successives. 53. (1) Every welding performance qualification card 53. (1) Chaque carte de qualification en soudure, must be issued with a file number by the inspector who délivrée par l’inspecteur qui dirige les épreuves de conducted the qualification tests. qualification est munie d’un numéro de dossier. (2) A welding operator shall stamp the file number (2) Le soudeur qualifié estampille sur la soudure set out on his or her welding performance card on a qu’il a faite le numéro de dossier inscrit sur sa carte de weld made by him or her to identify his or her work. qualification en soudure afin d’identifier son travail. (3) A manufacturer or contractor who employs one (3) Tout fabricant ou entrepreneur qui emploie un or more welding operators shall maintain a record of ou plusieurs soudeurs qualifiés tient un registre sur each welding operator employed by the manufacturer or chacun d’eux mentionnant le numéro de dossier qui contractor showing the file number that is on each figure sur la carte de qualification en soudure de chaque welding operator’s welding performance qualification soudeur qualifié. card. 54. (1) A welding performance qualification card 54. (1) La durée de validité de toute carte de expires 24 months after the day it is issued, unless it is qualification en soudure est de 24 mois à compter de sa extended under subsection (2). délivrance, à moins qu’elle ne soit prolongée en vertu du paragraphe (2). 30 (2) The chief inspector may extend a welding (2) La période de validité de la carte de performance qualification card for a period of time not qualification en soudure peut être prolongée par le chef exceeding three months. R-060-2005,s.10. inspecteur pour une période maximale de trois mois. R-060-2005, art. 10. 55. If a welding performance qualification card is lost 55. Si une carte de qualification en soudure est perdue or destroyed, a duplicate card may be issued on the ou détruite, une copie de la carte peut être délivrée à la request of the holder of the welding performance demande du titulaire et sur paiement du droit fixé à qualification card and the payment of the fee set out in l’annexe. R-078-2013, art. 6(1). the Schedule. R-078-2013,s.6(1). 56. (1) The classes of welding performance 56. (1) Les catégories de cartes de qualification en qualification cards are as follows: soudure s’établissent comme suit : (a) Grade A, which entitles the holder a) la catégorie A donne le droit à son (i) to engage in manual welding, and titulaire : (ii) to supervise other welding operators (i) d’effectuer de la soudure à la main, employed on the construction, (ii) de surveiller d’autres soudeurs installation or repair of boilers, qualifiés embauchés pour la pressure vessels and pressure piping; fabrication, le montage ou la (b) Grade B, which entitles the holder to réparation des chaudières, appareils engage in manual welding and to operate à pression et conduites sous pression; semi-automatic arc welding equipment. b) la catégorie B donne le droit à son titulaire d’effectuer de la soudure à la main et d’utiliser le matériel de soudure à l’arc semi-automatique. (2) The inspector who issues a welding (2) L’inspecteur qui délivre une carte de performance qualification card shall indicate the qualification en soudure indique le procédé de soudage, welding process, base material group, filler metal le groupe de matériaux de base, le groupe de métal group, thickness and positions for which the holder has d’apport, l’épaisseur et les postes pour lesquels le qualified on the welding performance qualification titulaire est compétent. card. 57. (1) To qualify for a Grade A welding performance 57. (1) Pour se voir décerner une carte de qualification qualification card, a candidate en soudure de catégorie A, le candidat doit : (a) shall provide proof that he or she holds a a) fournir la preuve qu’il est titulaire d’un journeyman’s certificate issued by the certificat de compagnon délivré par le government of a province or another gouvernement d’une province ou d’un territory and has not less than 12 months autre territoire et qu’il a plus de 12 mois experience as a welding operator; and d’expérience à titre de soudeur qualifié; (b) must pass the Class A qualification test. b) réussir l’épreuve de qualification en soudure de classe A. (2) A candidate wishing to challenge a (2) Le candidat qui désire tenter l’épreuve de qualification test for a Grade A welding performance qualification en soudure pour obtenir la carte de qualification card shall, at least 15 days before the date qualification en soudure de catégorie A présente au chef fixed for the test, deliver to the chief inspector an inspecteur au moins 15 jours avant la date prévue de application in the approved form, the fee set out in the l’épreuve, une demande rédigée selon la forme établie, Schedule and originals or copies of references vouching paye les droits fixés à l’annexe et fournit les originaux for the candidate’s experience. ou les copies des lettres de références attestant de son expérience. 31 (3) The chief inspector may approve or reject the (3) Le chef inspecteur peut approuver ou rejeter la application and, if the application is approved, shall demande et, si celle-ci est approuvée, prévient le advise the candidate of the time and place the test will candidat du lieu et de l’heure de l’épreuve. be held. R-078-2013,s.2,7,18(1). R-078-2013, art. 2, 7. 58. (1) To qualify for a Grade B welding performance 58. (1) Pour se voir décerner une carte de qualification qualification card, a candidate en soudure de catégorie B, le candidat doit : (a) shall provide proof that he or she has not a) fournir la preuve qu’il a plus de 24 mois less than 24 months experience as a d’expérience à titre de soudeur qualifié, welding operator, not less than six months dont au moins six mois ont été consacrés of which must be pipe welding; and à la soudure de tuyau; (b) must pass the Class B qualification test. b) réussir l’épreuve de qualification en soudure de classe B. (2) A candidate for a Grade B welding (2) Le candidat visant l’obtention d’une carte de performance qualification card shall, at least 15 days qualification en soudure de catégorie B, présente au before the date fixed for the test, deliver to the chief chef inspecteur, au moins 15 jours avant la date prévue inspector an application in the approved form and the de l’épreuve, une demande selon la forme établie et fee set out in the Schedule. paye le droit fixé à l’annexe. (3) The chief inspector may approve or reject the (3) Le chef inspecteur peut approuver ou rejeter la application and, if the application is approved, shall demande et, si celle-ci est approuvée, il prévient le advise the candidate of the time and place the test will candidat du lieu et de l’heure de l’épreuve. R-078- be held. R-078-2013,s.2,18(1). 2013, art. 2. 59. (1) A person who wishes to have a welding 59. (1) La personne qui désire obtenir une carte de performance qualification card issued to him or her qualification en soudure, délivrée en vertu du under subsection 50(2) of the Act shall submit an paragraphe 50(2) de la Loi, doit en faire la demande au application for it to the chief inspector and shall pay the chef inspecteur et payer le droit fixé à l’annexe. fee set out in the Schedule. (2) An inspector shall not issue a welding (2) Un inspecteur ne délivre pas de carte de performance qualification card under subsection 50(2) qualification en soudure en vertu du paragraphe 50(2) of the Act until the inspector is satisfied as to the de la Loi jusqu’à ce qu’il soit satisfait de l’identité du applicant’s identity, experience and qualifications and, demandeur, de son expérience et de ses qualifications. for that purpose, the inspector may require such À cet effet, l’inpecteur peut demander n’importe quelle evidence as he or she considers necessary. preuve qu’il estime nécessaire. 60. (1) To qualify for a welding performance 60. (1) Pour se voir décerner une carte de qualification qualification card other than those referred to in en soudure, autre que celles mentionnées à l’article 56, section 56, a candidate shall pass an additional le candidat doit réussir une épreuve supplémentaire de qualification test that conforms to a welding procedure qualification qui se conforme à une méthode de approved and registered under section 13. soudage agréée et enregistrée en vertu de l’article 13. (2) A candidate shall, at least 15 days before the (2) Le candidat doit, au moins 15 jours avant la date fixed for the qualification test, deliver to the chief date prévue pour passer l’épreuve de qualification, faire inspector an application in the approved form and the parvenir au chef inspecteur une demande rédigée selon fee set out in the Schedule. la forme établie et payer le droit fixé à l’annexe. 61. (1) If there is not a welding operator who is the 61. (1) Si aucun soudeur qualifié titulaire d’une carte holder of the appropriate class of a welding de qualification de la classe appropriée n’est disponible performance qualification card available in a remote dans une région éloignée et que l’ampleur ou la nature area and the extent or nature of a job or repair required du travail ou des réparations exigées dans cette région 32 in the remote area does not warrant the importation of ne justifie pas le déplacement d’un tel soudeur, such a welding operator, the inspector may, on payment l’inspecteur peut, sur paiement du droit fixé à l’annexe, of the fee set out in the Schedule, give a qualification faire subir sur place, à n’importe quel soudeur qualifié, test to any available welding operator on the type of une épreuve de qualification portant sur la tâche work called for on that particular operation and, if the particulière à effectuer. Si, de l’avis de l’inspecteur, les results of the test indicate, in the opinion of the résultats de l’épreuve montrent que le soudeur qualifié inspector, that the welding operator is capable, the possède des aptitudes, l’inspecteur peut soit : inspector may a) permettre au soudeur qualifié de (a) allow the welding operator to proceed commencer le travail ou la réparation sous with the job or repair under the direct le contrôle direct de l’inspecteur auquel supervision of the inspector and, during cas aucune carte de qualification en such supervision, no welding performance soudure n’est alors nécessaire; qualification card is required; or b) délivrer au soudeur qualifié, pour la (b) issue a provisional welding performance période de temps déterminée par qualification card to the welding operator l’inspecteur, une carte provisoire de for the job or repair for the period of time qualification en soudure pour le travail ou determined by the inspector. la réparation. (2) A complete report of the entire operation under (2) L’inspecteur prépare selon la formule établie un subsection (1) must be made by the inspector on the rapport complet des activités menées en vertu du approved form for the job or repair inspected, including paragraphe (1) pour l’inspection des réparations ou du particulars of the welding operator and tests given to the travail y compris les détails relatifs au soudeur qualifié et welding operator. R-078-2013,s.6(1),26. aux épreuves qu’on lui a fait subir. R-078-2013, art. 6(1). 62. (1) A qualification test on plate must be done in 62. (1) Toutes les épreuves de qualification en soudure accordance with Section IX of the ASME Boilers and sur plaque doivent être faites en conformité avec la Pressure Vessels Code. Partie IX du code ASME sur les chaudières et appareils à pression. (2) A welding operator who has not used a specific (2) Le soudeur qualifié qui n’a pas utilisé une welding process for a period of three months or more méthode spéciale de soudage pendant une période de may be required by the chief inspector to requalify in trois mois ou plus, peut relativement à cette méthode de respect of that welding process by passing tests as set soudage, être tenu par le chef inspecteur de se out in Section IX of the ASME Boilers and Pressure requalifier en réussissant les épreuves établies dans la Vessels Code. Partie IX du code ASME sur les chaudières et appareils à pression. 63. (1) The holder of a welding performance 63. (1) Le titulaire d’une carte de qualification en qualification card may be required to take a soudure peut être tenu de subir à tout moment une qualification test at any time when, in the opinion of an épreuve de qualification en soudure lorsque, de l’avis inspector, such a test is warranted to determine the de l’inspecteur, un tel examen est nécessaire pour present welding ability of the holder. établir la compétence en soudage actuelle du titulaire. (2) If a holder of a welding performance (2) Le titulaire d’une carte de qualification en qualification card is required to have a qualification test soudure, tenu de passer une épreuve de qualification, en under subsection (1), the holder shall pay the fee set out vertu du paragraphe (1), doit payer le droit fixé à in the Schedule, but payment of the fee may be waived l’annexe. Cependant, l’inspecteur peut ne pas exiger ce by an inspector when the holder is not due for droit lorsque le titulaire n’est pas tenu à cette époque de requalification for his or her welding performance l’année de se requalifier pour sa carte de qualification. qualification card. R-078-2013,s.6(2). 64. A qualification test must be conducted by an 64. Les épreuves de qualification sont menées par un inspector. inspecteur. 33 65. If a welding operator is continuously engaged on 65. Si un soudeur qualifié travaille de manière the construction of boilers and pressure vessels, constante à la construction des chaudières et appareils satisfactory X-ray evidence of his or her welding ability à pression, une preuve satisfaisante par radiographie may be accepted in lieu of a qualification test for the confirmant ses compétences en soudure peut être requalification of the welding operator. acceptée au lieu d’une épreuve de requalification. R-078-2013,s.6(1). R-078-2013, art. 6(1). 66. (1) Subject to subsection (2), a candidate who fails 66. (1) Sous réserve du paragraphe (2), le candidat qui a qualification test may not take the test again within échoue à une épreuve de qualification ne peut s’y one month after the day the qualification test was taken. présenter à nouveau dans le mois suivant le jour où l’épreuve a été passée. (2) An immediate retest may be given to a (2) Une reprise immédiate d’examen peut être candidate who fails a qualification test where the retest organisée pour un candidat qui n’a pas réussi l’épreuve is given in accordance with Section IX of the ASME de qualification lorsque cette reprise est organisée en Boilers and Pressure Vessels Code. conformité avec la Partie IX du code ASME sur les chaudières et appareils à pression. (3) Application for a subsequent qualification test (3) La demande en vue d’une nouvelle épreuve de must be made in the manner set out in subsections 57(2) qualification est faite de la façon prévue aux and 58(2). paragraphes 57(2) et 58(2). PART IV PARTIE IV FEES DROITS 67. The fees payable under the Act and these 67. Les droits exigibles en vertu de la Loi et du présent regulations are as set out in the Schedule. règlement sont fixés à l’annexe. 68. A shop inspection fee shall be paid on completion 68. Tout droit d’inspection en usine est payé à of an inspection of a boiler or pressure vessel under l’achèvement de l’inspection d’une chaudière et d’un construction or repair in the Northwest Territories. appareil à pression en construction ou en réparation R-078-2013,s.8(2). dans les Territoires du Nord-Ouest. 69. (1) Subject to subsection (2), a special inspection 69. (1) Sous réserve du paragraphe (2), inspection is an inspection of a boiler or pressure vessel other than spéciale s’entend de toute inspection d’une chaudière a periodic or initial inspection. ou d’un appareil à pression autre qu’une inspection première ou périodique. (2) If the chief inspector considers it appropriate, (2) Une première inspection peut être considérée an initial inspection may be considered a special comme une inspection spéciale lorsque, le chef inspection. inspecteur l’estime approprié. (3) In addition to any fees payable under these (3) Si un inspecteur doit faire une inspection, une regulations, if an inspector is away from his or her épreuve ou un réglage à l’extérieur de la collectivité où community of residence for the purpose of an il réside, un droit supplémentaire à ceux déjà exigibles inspection, test or adjustment, the person required to en vertu du présent règlement est prévu et, la personne pay the fees prescribed for the inspection, test or redevable du droit prescrit pour l’inspection, l’épreuve adjustment shall ou le réglage doit : (a) provide or pay for the inspector’s a) fournir ou payer le transport pour l’aller et transportation to and from the site of the le retour, de l’inspecteur jusqu’au lieu de inspection, test or adjustment; and l’inspection, de l’épreuve ou du réglage; (b) provide accommodation and meals for the b) fournir le gîte et le couvert à l’inspecteur 34 inspector or pay the inspector’s cost of ou les lui payer en conformité avec les accommodation and meals in accordance directives du gouvernement des with the guidelines of the Government of Territoires du Nord-Ouest pour les frais the Northwest Territories relating to duty de déplacement professionnel. travel expenses. R-076-97, art. 13; R-078-2013, art. 2. R-076-97,s.13; R-078-2013,s.2,6(2). 70. If a candidate fails to appear at an examination 70. Si un candidat ne se présente pas à un examen directed under subsection 47(1) or as advised under mené en vertu du paragraphe 47(1) ou suite à l’avis subsection 57(3) or 58(3), the candidate, subject to the donné en vertu du paragraphe 57(3) ou 58(3), le chef discretion of the chief inspector, forfeits the fee paid inspecteur peut, à sa discrétion, confisquer ces droits under these regulations. R-078-2013,s.6(1). payés en vertu du présent règlement. R-078-2013, art. 6(1). 71. A holder of a certificate of qualification that is 71. Le titulaire d’un certificat de qualification qui doit subject to renewal is exempt from paying renewal fees être renouvelé est exempté de payer les droits de while on active military service. renouvelement lorsqu’il fait son service militaire. 72. The chief inspector may provide copies of reports, 72. Le chef inspecteur peut fournir les copies des documents or designs that have been filed or registered rapports, documents ou conceptions qui ont été déposés under the Act or these regulations and the fee set out in ou enregistrés, en vertu de la Loi ou du présent the Schedule shall be paid on receipt of such copies. règlement. Les droits à payer sur réception de ces copies sont fixés à l’annexe. 73. Repealed, R-016-2013,s.2. 73. Abrogé, R-016-2013, art. 2. 74. Repealed, R-016-2013,s.2. 74. Abrogé, R-016-2013, art. 2. 35 SCHEDULE (Section 67) 1. (1) The fee payable for the survey, approval and registration of a design of a boiler with a capacity (a) not greater than 500 kW is ............................................... $ 88 (b) greater than 500 kW and not greater than 1,500 kW is.......................... $174 (c) greater than 1,500 kW is................................................. $348 (2) The fee payable for the survey, approval and registration of a design of a pressure vessel having a shell diameter (a) not greater than 0.6 m is................................................. $ 88 (b) greater than 0.6 m and not greater than 0.9 m is............................... $174 (c) greater than 0.9 m is.................................................... $348 (3) The fee payable for the survey, approval and registration of a design of a boiler or pressure vessel that is, in the opinion of the chief inspector, of a complex design is the greater of the fee set out in subsection (1) or (2), as the case may be, and (a) for each full regular working day an inspector is required....................... $348 (b) for each hour or part of an hour an inspector is required if the inspector is required for part of a regular working day..................... $ 69 (4) The fee payable for the survey, approval and registration of a design of a plant is, for each hour or part of an hour............................................................. $ 69 (5) The fee payable for the survey, approval and registration of a design of fittings is (a) for each size, type and pressure registered................................... $ 88 (b) for collective registration as provided for in subsection 6(3)..................... $174 (c) for a revision to or updating of a collective fitting registration.................... $ 58 (6) If an approved design of a boiler, pressure vessel or fitting is revised, the fee payable for each hour or part of an hour an inspector is required to survey, approve and register the design is ...... $ 69 (7) The fee payable for review and approval of a welding procedure under section 13 is, for each hour or part of an hour............................................................. $ 69 (8) The fee payable for the review and approval of a quality control manual is, for each hour or part of an hour................................................................... $ 69 (9) The fee payable for the registration of a design of a boiler, pressure vessel or fitting, where no survey is conducted by the chief inspector, is......................................... $107 2. The fee payable for an installation permit is......................................... $ 56 36 ANNEXE (article 67) 1. (1) Le droit exigible pour l’étude, l’agrément et l’enregistrement de la conception d’une chaudière ayant une capacité : a) d’au plus 500 kW, est de................................................. 88 $ b) excédant 500 kW et d’au plus 1 500 kW, est de............................... 174 $ c) excédant 1 500 kW, est de ............................................... 348 $ (2) Le droit exigible pour l’étude, l’agrément et l’enregistrement de la conception d’un appareil à pression ayant un corps d’un diamètre : a) d’au plus 0,6 mètre, est de ............................................... 88 $ b) excédant 0,6 mètre et d’au plus 0,9 mètre, est de.............................. 174 $ c) excédant 0,9 mètre, est de................................................ 348 $ (3) Le droit exigible pour l’étude, l’agrément et l’enregistrement de la conception d’une chaudière ou d’un appareil à pression dont la conception est compliquée, selon l’opinion du chef inspecteur, correspond au droit le plus élevé fixé au paragraphe (1) ou (2) selon le cas, et au montant ci-dessous : a) pour chaque journée régulière de travail complète pour laquelle un inspecteur est requis .................................................................... 348 $ b) pour chaque heure, tranche d’heure pour laquelle un inspecteur est requis lorsqu’un inspecteur est requis pour une partie d’une journée régulière de travail............. 69 $ (4) Le droit exigible pour l’étude, l’agrément et l’enregistrement de la conception d’une installation, pour chaque heure ou tranche d’heure, est de ................................. 69 $ (5) Le droit exigible pour l’étude, l’agrément et l’enregistrement de la conception des accessoires est fixé ci-dessous : a) pour chaque dimension, modèle et pression enregistré.......................... 88 $ b) pour un enregistrement collectif prévu au paragraphe 6(3) ...................... 174 $ c) pour la révision ou la mise à jour d’un enregistrement collectif d’accessoire......... 58 $ (6) Lorsque la conception agréée d’une chaudière, d’un appareil à pression ou d’un accessoire est révisée, le droit exigible pour chaque heure ou tranche d’heure pour laquelle un inspecteur est requis de l’étudier, de l’approuver et de l’enregistrer, est de .................... 69 $ (7) Le droit exigible pour l’examen et l’agrément d’une soudure faite en vertu de l’article 13, pour chaque heure ou tranche d’heure, est de........................................... 69 $ (8) Le droit exigible pour l’examen et l’agrément d’un registre de contrôle de la qualité, pour chaque heure ou tranche d’heure, est de ............................................... 69 $ (9) Le droit exigible pour l’enregistrement de la conception d’une chaudière, d’un appareil à pression ou d’un accessoire, lorsqu’aucune expertise n’est menée par le chef inspecteur, est de.... 107 $ 2. Le droit exigible pour un permis d’installation est de.................................. 56 $ 37 3. (1) The fee payable for the annual registration of a boiler having a power rating (a) not greater than 500 kW is ............................................... $104 (b) greater than 500 kW and not greater than 5,000 kW is.......................... $129 (c) greater than 5,000 kW and not greater than 10,000 kW is....................... $227 (d) greater than 10,000 kW and not greater than 15,000 kW is...................... $331 (e) greater than 15,000 kW and not greater than 20,000 kW is...................... $435 (f) greater than 20,000 kW and not greater than 25,000 kW is...................... $538 (g) greater than 25,000 kW and not greater than 35,000 kW is...................... $641 (h) greater than 35,000 kW is................................................ $848 (2) The fee payable for the annual registration of a pressure vessel having a shell diameter (a) not greater than 0.6 m is................................................. $ 88 (b) greater than 0.6 m and not greater than 0.9 m is............................... $129 (c) greater than 0.9 m is.................................................... $173 plus $43 for each metre or part of a metre over 1 metre (3) The fee payable for a certificate of inspection is.................................. nil 4. The fee payable for testing fittings under subsection 6(6), adjusting safety valves under subsection 25(2) or conducting a shop inspection or special inspection on (a) a regular working day from 8:30 a.m. to 5 p.m., for each hour or part of an hour is ... $ 69 (b) a regular working day before 8:30 a.m., after 5 p.m. or for more than 7.5 hours in the day or on a Saturday, for each hour or part of an hour is ........................... $105 (c) a Sunday or holiday, for each hour or part of an hour is......................... $140 5. (1) The following fees are payable for the examination required for the following certificates of qualification or for a certificate issued under section 45: (a) Class 1 operating engineer’s certificate of qualification, (i) if the examination is written at one sitting ............................... $279 (ii) if all papers of an examination are not written at one sitting, for each paper ..... $ 35 (b) Class 2 operating engineer’s certificate of qualification, (i) if the examination is written at one sitting ............................... $209 (ii) if all papers of an examination are not written at one sitting, for each paper ..... $ 35 (c) Class 3 operating engineer’s certificate of qualification, (i) if the examination is written at one sitting ............................... $140 (ii) if all papers of an examination are not written at one sitting, for each paper ..... $ 35 (d) Class 4 operating engineer’s certificate of qualification, (i) if the examination is written at one sitting ............................... $ 69 (ii) if all papers of an examination are not written at one sitting, for each paper ..... $ 35 (e) Class 5 operating engineer’s certificate of qualification......................... $ 47 (2) The fee payable for a temporary certificate of qualification is ....................... $ 58 38 3. (1) Le droit exigible pour l’enregistrement annuel d’une chaudière qui a un régime de puissance : a) d’au plus 500 kW, est de................................................. 104 $ b) excédant 500 kW et d’au plus 5 000 kW, est de............................... 129 $ c) excédant 5 000 kW et d’au plus 10 000 kW, est de ............................ 227 $ d) excédant 10 000 kW et d’au plus 15 000 kW, est de ........................... 331 $ e) excédant 15 000 kW et d’au plus 20 000 kW, est de ........................... 435 $ f) excédant 20 000 kW et d’au plus 25 000 kW, est de ........................... 538 $ g) excédant 25 000 kW et d’au plus 35 000 kW, est de ........................... 641 $ h) excédant 35 000 kW, est de .............................................. 848 $ (2) Le droit exigible pour l’enregistrement annuel d’un appareil à pression ayant un corps d’un diamètre : a) d’au plus 0,6 mètre, est de ............................................... 88 $ b) excédant 0,6 mètre et d’au plus 0,9 mètre, est de.............................. 129 $ c) excédant 0,9 mètre, est de................................................ 173 $ plus 43 $ pour chaque mètre ou tranche de mètre au-delà de un mètre (3) Le droit exigible pour un certificat d’inspection est de............................. aucun 4. Le droit exigible pour tester les accessoires en vertu du paragraphe 6(6), ajuster les valves de sécurité en vertu du paragraphe 25(2) ou faire une inspection d’usine ou une inspection spéciale est fixé ci-dessous : a) pour une journée régulière de travail de 8h30 à 17h00, pour chaque heure ou tranche d’heure .............................................................. 69 $ b) pour une journée régulière avant 8h30 ou après 17h00, pour chaque heure ou tranche d’heure .............................................................. 105 $ c) pour un dimanche ou un congé férié, pour chaque heure ou tranche d’heure......... 140 $ 5. (1) Le droit suivant est exigible pour passer l’examen visant l’obtention des certificats de qualification ou du certificat délivré en vertu de l’article 45 : a) certificat de qualification de mécanicien de machines fixes de classe 1 : (i) lorsque l’examen se déroule en une seule séance.......................... 279 $ (ii) pour chaque travail, lorsque les épreuves ne se déroulent pas en une seule séance ................................................................ 35 $ b) certificat de qualification de mécanicien de machines fixes de classe 2 : (i) lorsque l’examen se déroule en une seule séance.......................... 209 $ (ii) pour chaque travail, lorsque les épreuves ne se déroulent pas en une seule séance ................................................................ 35 $ c) certificat de qualification de mécanicien de machines fixes de classe 3 : (i) lorsque l’examen se déroule en une seule séance.......................... 140 $ (ii) pour chaque travail, lorsque les épreuves ne se déroulent pas en une seule séance ................................................................ 35 $ d) certificat de qualification de mécanicien de machines fixes de classe 4 : (i) lorsque l’examen se déroule en une seule séance.......................... 69 $ (ii) pour chaque travail, lorsque les épreuves ne se déroulent pas en une seule séance ................................................................ 35 $ e) certificat de qualification de mécanicien de machines fixes de classe 5............. 47 $ (2) Le droit exigible pour obtenir un certificat de qualification temporaire est de ........... 58 $ 39 (3) The following fee is payable for the renewal of a certificate of qualification under section 32: (a) if the application to renew the certificate is made before, on or within one year after the day the certificate expires................................................ $ 88 (b) if the application to renew the certificate is made after one year after the day the certificate expires...................................................... $ 88 plus $ 88 for each three year period or part of a three year period that has elapsed since the certificate expired (4) The following fees are payable for a certificate of qualification issued under subsection 44(1): (a) Class 1 .............................................................. $140 (b) Class 2 .............................................................. $105 (c) Class 3 .............................................................. $ 69 (d) Class 4 ..............................................................
Part document.segment-4
Boilers Pressure Vessels Regulation 1 — segment 4
- document.segment-4 Verify source ↗
Boilers Pressure Vessels Regulation 1 — segment 4
This provision sets fees for qualification tests, certificates, record searches, copies, and related welding documents.
$ 46 (e) Class 5 .............................................................. $ 23 6. (1) The fee payable for a Class A or Class B qualification test required by paragraph 57(1)(b) or 58(1)(b), respectively, or for a qualification test given under section 60, 61 or 63 (a) if material is supplied by the chief inspector or an inspector is ................... $153 (b) if material is supplied by the candidate is.................................... $ 58 (2) The fee payable for a welding performance qualification card issued under subsection 50(2) of the Act is..................................................................... $ 58 7. (1) The fee payable for a search of official records is................................. $ 23 (2) The fee payable for a duplicate certificate of inspection, a duplicate certificate of qualification, a duplicate welding performance qualification card or a photocopy or certified copy of a report or other document is........................................................ $ 23 (3) The fee payable for a copy of a design that has been registered is the actual cost of the copy. R-033-2026,s.2. 40 (3) Le droit suivant est exigible pour le renouvellement d’un certificat de qualification en vertu de l’article 32 : a) avant la date d’expiration du certificat ou dans l’année qui suit cette date........... 88 $ b) lorsque la demande de renouvellement est faite plus d’un an après la date d’expiration du certificat................................................. 88 $ plus 88 $ par période ou partie de période de 3 ans qui se sont écoulées depuis l a d a t e d’expiration du certificat (4) Le droit suivant est exigible pour obtenir un certificat de qualification délivré en vertu du paragraphe 44(1) : a) classe 1.............................................................. 140 $ b) classe 2.............................................................. 105 $ c) classe 3.............................................................. 69 $ d) classe 4.............................................................. 46 $ e) classe 5.............................................................. 23 $ 6. (1) Le droit exigible pour passer une épreuve de qualification de soudeur de catégorie A ou B exigée en vertu de l’alinéa 57(1)b) ou 58(1)b), respectivement, ou pour passer une épreuve exigée en vertu de l’article 60, 61 ou 63 est fixé ci-dessous : a) lorsque le matériel est fourni par l’inspecteur ou l’inspecteur en chef .............. 153 $ b) lorsque le matériel est fourni par le candidat ................................. 58 $ (2) Le droit exigible pour obtenir une carte de qualification en soudure délivrée en vertu du paragraphe 50(2) de la Loi est de .................................................... 58 $ 7. (1) Le droit exigible pour une recherche dans les dossiers officiels est de................. 23 $ (2) Le droit exigible pour faire une copie du certificat d’inspection, du certificat de qualification, d’une carte de qualification en soudure ou pour faire une photocopie ou copie certifiée conforme d’un rapport ou d’un autre document, est de.................................... 23 $ (3) Le droit exigible pour faire une copie d’une conception qui a été enregistrée correspond aux coûts réels de la copie. R-033-2026, art. 2. © 2026 Territorial Printer © 2026 l’imprimeur territorial Yellowknife, N.W.T. Yellowknife (T. N.-O.) 41
Provision text is displayed from LexChat’s stored statute record. Use the official source links to verify amendments, commencement, and current legal force.
Ask AI about this statute
Boilers Pressure Vessels Regulation 1
Sign in to ask AI about this statute
Sign in to start authenticated, citation-grounded statute research.