Electricity Regulations, 1932.
The occupier must comply with these electricity regulations, and workers and agents must conduct their work in accordance with them. The Minister may exempt certain premises or grant exemptions by Order, subject to conditions, and may revoke those Orders.
- Jurisdiction
- Ireland
- Instrument
- Regulation
- Version
- Undated source snapshot
- Language
- en
- Official source
- View official record ↗
Statute overview
About this statute
This page preserves the statute’s identified version, provision structure, official source link, and stored legal text for reading and research.
Search within this statute
Search all stored provisions in this version.
Legal text
Provisions of Electricity Regulations, 1932.
Showing 1 of 1
- § Verify source ↗
Electricity Regulations, 1932.
The occupier must comply with these electricity regulations, and workers and agents must conduct their work in accordance with them. The Minister may exempt certain premises or grant exemptions by Order, subject to conditions, and may revoke those Orders.
S.I. No. 7/1932 - Electricity Regulations, 1932. STATUTORY RULES AND ORDERS. 1932. No. 7. ELECTRICITY REGULATIONS, 1932. FACTORY AND WORKSHOP. DANGEROUS AND UNHEALTHY INDUSTRIES. In pursuance of Section 79 of the Factory and Workshop Act, 1901, I hereby make the following Regulations in respect of the Generation, Transformation, Distribution and Use of Electrical Energy and direct that they shall apply in any factory or workshop, or any place to which the provisions of Section 79 of the Factory and Workshop Act, 1901, are applied by that Act. These Regulations shall come into force on the 1st April, 1932, except as regards such electrical installations as were not subject to the Electricity Regulations made on the 23rd December, 1908, in respect of which they shall apply as from the 1st April, 1933. From the 1st April, 1932, the Regulations dated 23rd December, 1908,* shall be revoked. It shall be the duty of the occupier to comply with these Regulations. And it shall be the duty of all agents, workmen, and persons employed to conduct their work in accordance with these Regulations. DEFINITIONS.† " means the difference of electrical potential between any two , or between a and earth as measured by a suitable electrostatic volt-meter. Low pressure " means a in a ) normally not exceeding 250 volts to earth, or ) normally not exceeding 500 volts between in a that is not High pressure " means a in a ) normally exceeding 250 volts to earth, or ) normally exceeding 500 volts between in a that is not " means an electrical system in which all the are electrically connected to a common source of electro-motive force. means an electrical conductor arranged to be electrically connected to a means electrical apparatus, and includes all apparatus, machines, and fittings in which are used, or of which they form a part. means an electrical circuit forming a or branch of a "Insulating stand" means a floor, platform, stand or mat. "Insulating screen" means a screen "Insulating boots" means boots "Insulating gloves" means gloves of such size, quality, and construction according to the circumstances of the use thereof, that a person is thereby adequately protected from danger. "Covered with insulating material" means adequately covered with insulating material of such quality and thickness that there is no means not insulating material means electrically charged. means at, or about, zero potential, and disconnected from any live system. means connected to the general mass of earth in such manner as will ensure at all times an immediate discharge of electrical energy without means any premises or that part of any premises in which electrical energy at high pressure is distributed, or in which electrical energy is transformed or converted to or from high pressure , except for the purpose of working instruments, relays, or similar axiliary means the collection of switches or fuses, , and other in connection therewith, used for the purpose of controlling the current or in any or part of a "Switchboard passage-way" means any passage-way or compartment large enough for a person to enter, and used in connection with a "Authorised person" means ( ) the occupier, or ( ) a contractor for the time being under contract with the occupier, or ( ) a person employed, appointed, or selected by the occupier, or by a contractor as aforesaid, to carry out certain duties incidental to the generation, transformation, distribution, or use of electrical energy, such occupier, contractor, or person being a person who is competent for the purposes of the regulation in which the term is used. means danger to health or danger to life or limb from shock, burn, or other injury to persons employed, or from fire attendant upon the generation, transformation, distribution, or use of electrical energy. "Public supply" means the supply of electrical energy ( ) by any local authority, company, or person authorised by Act of the Oireachtas or Provisional Order confirmed by the Oireachtas or by licence or Order of the Electricity Supply Board to give a supply of electrical energy; or ( ) otherwise under Electricity Supply Board Regulations. "The Minister" means the Minister for Industry and Commerce for the time being. means prescribed for the time being by the Minister for Industry and Commerce. 1. Nothing in these Regulations shall apply to any service lines or on the supply side of the consumer's terminals, or to any chamber containing such service lines or , where the supply is given from outside under Electricity Supply Board Regulations; provided always that no metal is exposed so that it may be touched. 2. If the occupier can show, with regard to any requirement of these Regulations, that the special conditions in his premises are such as adequately to prevent , that requirement shall be deemed to be satisfied; and the Minister may by Order direct that any class of special conditions defined in the Order shall be deemed for the purposes of all or any of the requirements of these Regulations adequately to prevent , and may revoke such Order. 3. Nothing in these Regulations shall apply to any process or so constructed and protected and such special precautions taken as may be necessary to prevent 4. The may, by Order, exempt from the operation of all or any of these Regulations any premises to which any special rules or regulations under any other Act as to the generation, transformation, distribution or use of electrical energy apply; and may revoke such Order. 5. The may, if satisfied that safety is otherwise practically secured, or that exemption is necessary on the ground of emergency or special circumstances, grant such exemption by Order, subject to any conditions that may be prescribed therein; and may revoke such Order. 1. All shall be sufficient in size and power for the work they are called upon to do, and so constructed, installed, protected, worked and maintained as to prevent so far as is reasonably practicable. 2. All shall either be covered with insulating material , and further efficiently protected where necessary to prevent , or they shall be so placed and safeguarded as to prevent so far as is reasonably practicable. 3. Every switch, switch-fuse, circuit-breaker, and isolating link shall be:—( ) so constructed, placed, or protected as to prevent ; ( ) so constructed and adjusted as accurately to make and to maintain good contact; ( ) provided with an efficient handle or other means of working, insulated from the , and so arranged that the hand cannot inadvertently touch metal; ( ) so constructed or arranged that it cannot accidentally fall or move into contact when left out of contact. 4. Every switch intended to be used for breaking a and every circuit-breaker shall be so constructed that it cannot with proper care be left in partial contact. This applies to each pole of double-pole or multipole switches or circuit-breakers. Every switch intended to be used for breaking a and every circuit-breaker shall be so constructed that an arc cannot accidentally be maintained. 5. Every fuse, and every automatic circuit-breaker used instead thereof, shall be so constructed and arranged as effectively to interrupt the current before it so exceeds the working rate as to involve . It shall be of such construction or be so guarded or placed as to prevent from over-heating, or from arcing or the scattering of hot metal or other substance when it comes into operation. Every fuse shall be either of such construction or so protected by a switch that the fusible metal may be readily renewed without 6. Every electrical joint and connection shall be of proper construction as regards conductivity, insulation, mechanical strength and protection. 7. Efficient means, suitably located, shall be provided for cutting off all from every part of a , as may be necessary to prevent 8. Efficient means suitably located shall be provided for protecting from excess of current every part of a , as may be necessary to prevent 9. Where one of the of a is connected to earth, no single-pole switch, other than a link for testing purposes or a switch for use in controlling a generator or transformer, shall be placed in such or any branch thereof. A switch, or automatic or other cut-out, may, however, be placed in the connection between the and earth at the generating station or transformer station, for use in testing and emergencies only. 10. Where one of the main of a and uninsulated, no switch, fuse, or circuit-breaker shall be placed in that or in any connected thereto, and the said shall be Nevertheless, switches, fuses, or circuit-breakers may be used to break the connection with the generators or transformers supplying the power; provided that in no case of bare conductor the connection of the with earth is thereby broken. 11. Every motor, converter and transformer shall be protected by efficient means suitably placed, and so connected that all may thereby be cut off from the motor, converter or transformer as the case may be, and from all in connection therewith; provided, however, that where one point of the is connected to earth, there shall be no obligation to disconnect on that side of the which is connected to earth. 12. Every electrical motor shall be controlled by an efficient switch or switches for starting and stopping, so placed as to be easily worked by the person in charge of the motor. In every place in which machines are being driven by any electric motor, there shall be means at hand for either switching off the motor or stopping the machines if necessary to prevent 13. Every flexible wire for portable shall be connected to the either by efficient permanent joints or connections, or by a properly constructed connector. In all cases where the person handling portable or pendant lamps with switches, would be liable to get a shock through a conducting floor or conducting work or otherwise, if the metal work of the portable became charged, the metal work must be efficiently ; and any flexible metallic covering of the shall be itself efficiently and shall not itself be the only earth connection for the metal of the And a lampholder shall not be in metallic connection with the guard or other metal work of a portable lamp. and its flexible wire shall be controlled by efficient means suitably located, and capable of cutting off the , and the metal work shall be efficiently independently of any flexible metallic cover of the , and any such flexible covering shall itself be independently 14. The general arrangement of shall, so far as reasonably practicable, be such that— ) All parts which may have to be adjusted or handled are readily accessible. ) The course of every may where necessary be readily traced. , not arranged for connection to the same , are kept well apart, and can where necessary be readily distinguished. ) All bare conductors are so placed or protected as to prevent from accidental short circuit. 15. Every bare conductors normally so exposed that they may be touched, shall, if not located in an area or areas set apart for the purposes thereof, where necessary be suitably fenced or enclosed. No person except an authorised person , or a person acting under his immediate supervision, shall for the purpose of carrying out his duties have access to any part of an area so set apart. 16. All appertaining to a and requiring handling, shall so far as practicable be so placed or arranged as to be operated from the working platform of the , and all measuring instruments and indicators connected therewith shall, so far as practicable, be so placed as to be observed from the working platform. If such be worked or observed from any other place, adequate precautions shall be taken to prevent 17. At the working platform of every , and in every switchboard passage-way , if there be bare conductors exposed or arranged to be exposed when so that they may be touched, there shall be a clear and unobstructed passage of ample width and height, with a firm and even floor. Adequate means of access, free from shall be provided for every The following provisions shall apply to all such working platforms and , unless the bare conductors , whether overhead or at the sides of the , are otherwise adequately protected against by divisions or screens or other suitable means:— ) Those constructed for low-pressure switchboards shall have a clear height of not less than 7 ft. and a clear width measured from of not less than 3 ft. ) Those constructed for high-pressure switchboards , other than operating desks or panels working solely at , shall have a clear height of not less than 8 ft. and a clear width measured from bare conductor of not less than 3 ft. 6 in. Bare conductors shall not be exposed on both sides of the switchboard passage-way unless either (i) clear width of the passage is in the case of low-pressure not less than 4 ft. 6 in., and in the case of not less than 8 ft., in each case measured between bare conductors , or (ii) the on one side are so guarded that they cannot be accidentally touched. 18. In every ) Every high-pressure conductor within reach from the working platform or in any switchboard passage-way shall be so placed or protected as adequately to prevent ) The metal cases of all instruments working at shall be either or completely enclosed with insulating covers. ) All metal handles of switches, and, where necessary to prevent , all metal gear for working the switches, shall be ) When work has to be done on any , then, unless the be otherwise so arranged as to secure that the work may be carried out without , either (i) the shall be made , or (ii) if the said be so arranged that the thereof can be made in sections, and so separated by permanent or removable divisions or screens from all adjoining sections of which the , that work on any section may be carried out without , that section on which work has to be done shall be made 19. All parts of generators, motors, transformers, or other similar , at and within reach from any position in which any person employed may require to be, shall be, so far as reasonably practicable, so protected as to prevent 20. Where a supply is transformed for use at a lower , or energy is transformed up to above , suitable provision shall be made to guard against by reason of the lower-pressure becoming accidentally charged above its normal by leakage or contact from the higher-pressure 21. Where necessary to prevent , adequate precautions shall be taken either by or by other suitable means to prevent any metal other than the from becoming electrically charged. 22. Adequate precautions shall be taken to prevent any from being accidentally or inadvertently electrically charged when persons are working thereon. 23. Where necessary, adequately to prevent insulating stands shall be provided and kept permanently in position, and shall be maintained in sound condition. 24. Portable insulating stands, screens, boots, gloves , or other suitable means shall be provided and used when necessary adequately to prevent , and shall be periodically examined by an authorised person. 25. Adequate working space and means of access, free from , shall be provided for all that has to be worked or attended to by any person. 26. All those parts of premises in which is placed shall be adequately lighted to prevent 27. All exposed to the weather, wet, corrosion, inflammable surroundings or explosive atmosphere, or used in any process or for any special purpose other than for lighting or power, shall be so constructed or protected, and such special precautions shall be taken as may be necessary adequately to prevent in view of such exposure or use. 28. No person except an authorised person or a competent person acting under his immediate supervision shall undertake any work where technical knowledge or experience is required in order adequately to avoid ; and no person shall work alone in any case in which the Minister directs that he shall not. No person except an authorised person , or a competent person acting under his immediate supervision, shall undertake any repair, alteration, extension, cleaning, or such work where technical knowledge or experience is required in order to avoid , and no one shall do such work unaccompanied. Where a contractor is employed, and the to be avoided is under his control, the contractor shall appoint the authorised person , but if the to be avoided is under the control of the occupier, the occupier shall appoint the authorised person. 29. Instructions in the form as to the treatment of persons suffering from electric shock shall be affixed in all premises where electrical energy is generated, transformed, or used. 30. Every shall be substantially constructed, and shall be so arranged that no person other than an authorised person can obtain access thereto otherwise than by the proper entrance, or can interfere with the therein from outside: and shall be provided with efficient means of ventilation and be kept dry. 31. Every shall be under the control of an authorised person , and none but an authorised person or a person acting under his immediate supervision shall enter any part thereof where there may be 32. Every underground not otherwise easily and safely accessible shall be provided with adequate means of access by a door or trap-door, with a staircase or ladder securely fixed and so placed that no part of any or any bare conductor shall be within reach of a person thereon: Provided, however, that the means of access to such shall be a doorway and staircase ( ) if any person is regularly employed therein, otherwise than for inspection or cleaning, or ( ) if the is not of ample dimensions and there is therein moving machinery other than ventilating fans. P. McGILLIGAN, 10adh Feabhra, 1932. Aire um Thionnscail agus Thráchtála (Minister for Industry and Commerce). * S. R. and O. 1908, No. 1312.
Provision text is displayed from LexChat’s stored statute record. Use the official source links to verify amendments, commencement, and current legal force.
Ask AI about this statute
Electricity Regulations, 1932.
Sign in to ask AI about this statute
Sign in to start authenticated, citation-grounded statute research.
Sign inLexChat organizes source-backed legal information for research. Verify amendments, commencement, and current legal force with the official publisher before relying on it.