Building Control Ordinance, 2013
This provision sets up building control rules, requires plan approval before covered building work starts, and lets inspectors check, enforce, and issue occupancy certificates.
- Jurisdiction
- St Helena
- Instrument
- Ordinance
- Version
- Undated source snapshot
- Language
- en
- Official source
- View official record ↗
Statute overview
About this statute
This provision sets up building control rules, requires plan approval before covered building work starts, and lets inspectors check, enforce, and issue occupancy certificates. This provision sets building control standards for moisture resistance, fire safety, stairs and ramps, glazing, accessibility, sound insulation, drainage, sanitation, and room sizes in buildings. This part sets building-safety requirements for sanitation, heating, LPG storage, and electrical installations.
Search within this statute
Search all stored provisions in this version.
Legal text
Provisions of Building Control Ordinance, 2013
Showing 3 of 3
Part document.segment-1
Building Control Ordinance, 2013 — segment 1
- document.segment-1 Verify source ↗
Building Control Ordinance, 2013 — segment 1
This provision sets up building control rules, requires plan approval before covered building work starts, and lets inspectors check, enforce, and issue occupancy certificates.
ST HELENA REVISED EDITION OF THE LAWS, 2017 LAND OWNERSHIP & USE BUILDING CONTROL ORDINANCE, 20131 Ordinance 10 of 2013 In force 26 August 2014 Amended by L.N. 21/2013 Subsidiary legislation: BUILDING REGULATIONS, 2019 Page 5 Legal Notice 20 of 2019 ______________________ BUILDING CONTROL ORDINANCE, 2013 ARRANGEMENT OF SECTIONS 1. Citation, commencement and interpretation 2. Building Regulations to be made 3. Building Inspectors 4. Contravention of building regulations 5. Offences AN ORDINANCE to make provision for Building Regulations; and for the appointment of Building Inspectors; and for connected or incidental matters. Citation, commencement and interpretation 1. (1) This Ordinance may be cited as the Building Control Ordinance, 2013. (2) Omitted (3) Omitted (4) In this Ordinance, any word or phrase that has been assigned a meaning in the Land Planning and Development Control Ordinance, 2013 bears the same meaning and— “Building Inspector” includes the Chief Building Inspector, and any Assistant Building Inspector, appointed under section 3; and “building” includes both new buildings and alterations of, or extensions to, existing buildings. 1 Under section 10 of the Revised Edition of the Laws Ordinance, 1999 this text is authoritative and is the sole authentic edition in respect of the law contained in it as at 1 November 2017. 2 Building Regulations to be made 2. (1) The Governor in Council may, for the purposes referred to in subsection (2), make regulations (to be known as “Building Regulations”) with respect to— (a) the methods and standards of construction of buildings and structures and systems associated with buildings, including such structures and systems for the supply of water and electricity and disposal of waste water; and (b) matters generally, for carrying the purposes under subsection (2) into effect. (2) The purposes of the Building Regulations are to— (a) secure the health, safety, welfare and convenience of persons in or about buildings and of others who may be affected by buildings or matters connected with buildings; (b) further the conservation of energy; (c) prevent waste, undue consumption, misuse or contamination of water and make arrangements for disposal of waste water; (d) further the prevention or detection of crime. (3) Building Regulations may apply to–– (a) all buildings in St Helena; or (b) prescribed types or classes of buildings, or buildings in prescribed places or localities, and may make different provision to apply to different buildings, parts of buildings or classes of buildings, or to buildings in different places or localities. (4) Except in so far as the Building Regulations provide otherwise, the requirements of the Building Regulations apply in relation to work carried out, or proposed to be carried out, by or on behalf of the Crown. (5) Building Regulations may include provisions requiring–– (a) the depositing with a Building Inspector of plans, sections, specifications and written particulars of any building which any person proposes or intends to construct or erect; (b) the giving of notices and certificates, the inspection of work, (including the power to require the uncovering of work which has been covered prior to inspection), the testing of drains and sewers, and the taking by a Building Inspector of samples of materials to be used in the construction of buildings or in the execution of other works; and (c) the payment of fees for anything done or to be done pursuant to this Ordinance or the Building Regulations. Building Inspectors 3. (1) The Governor must appoint a Chief Building Inspector, and such number (if any) of Building Inspectors and Assistant Building Inspectors as the Governor considers necessary or convenient for the purposes of carrying into effect the provisions of this Ordinance. (2) The Building Inspectors have the powers and functions conferred upon them by this Ordinance or by Building Regulations, and must exercise those powers and perform those functions under the general superintendence of the Chief Planning Officer appointed under the Land Planning and Development Control Ordinance, 2013. 3 (3) The Building Inspectors must administer and enforce this Ordinance and the Building Regulations and, for that purpose, may (at any reasonable time) enter on any land or in any building–– (a) for the purpose of ascertaining whether there is, or has been, a contravention of the Building Regulations on or in connection with the land or building; (b) for the purpose of taking any action, or executing any work, authorised or required by this Ordinance or by the Building Regulations; or (c) generally for the purpose of the performance of his functions under this Ordinance or the Building Regulations. (4) Before exercising any powers under subsection (3), a Building Inspector must, so far as is practicable, identify himself or herself to the occupier or other person who is or appears to be in control of the land or building concerned. (5) The powers of entry conferred by this section include permitting a Building Inspector to make any examination and inquiries necessary to achieve the intended purpose of such entry. Contravention of building regulations 4. (1) Subject to subsection (7), if it appears to the Chief Building Inspector that there has been a contravention of the Building Regulations on or in connection with any land or building, he or she may issue and serve on the owner or occupier of such land or building a notice (hereinafter referred to as an “enforcement notice”) ordering the owner or occupier to take any steps necessary to ensure that the land or building complies with the Building Regulations. (2) An enforcement notice must state–– (a) the person or persons to whom it is addressed; (b) the land or building to which it relates; (c) the Building Regulation which has been contravened; (d) the steps which must be taken to rectify the alleged contravention and the time, being not less than 2 months, within which such steps must be taken; (e) the powers of the Chief Building Inspector under subsection (4) in the case of default in compliance with the notice; (f) the penalties which might be incurred if the steps specified in paragraph (d) are not taken; (g) the right of the owner and occupier of the land or building which is the subject of the enforcement notice to appeal against the enforcement notice under subsection (6). (3) The steps which may be specified for the purposes of subsection (2)(d) are all or any of the following, namely to–– (a) demolish or remove a building in whole or in part; (b) erect, re-erect or alter a building in whole or in part; (c) carry out any building or other operations on the land or building to which the notice relates; (4) If a person on whom an enforcement notice has been served fails to take the action required by the notice to rectify the contravention, the Chief Building Inspector may, subject to any appeal against the issue of the enforcement notice, enter the land or building and take all necessary action in respect of the contravention to enforce the notice as he or she sees fit. 4 (5) If the Chief Building Inspector has exercised any power under subsection (4), he or she may recover as a civil debt, from any person upon whom the notice under subsection (1) has been served, the expenses reasonably incurred in the exercise of the power. (5A) If a person who is entitled to appeal under subsection (6) has failed to make such an appeal, the person is not entitled in any proceedings to dispute the validity of the action taken by the Chief Building Inspector under subsection (4) or (5) upon any ground that could have been entertained on such an appeal. (6) A person to whom an enforcement notice is issued under subsection (1) may appeal to the Tribunal established under the Land Planning and Development Control Ordinance, 2013. (6A) The Building Regulations must prescribe the procedures to be adopted in relation an appeal under subsection (5), and the powers of the Tribunal when determining such an appeal. (7) An enforcement notice under subsection (1) must not be issued in respect of any building after a period of 5 years from the date on which the contravention of the building regulations first occurred. Offences 5. It is an offence for a person, without reasonable excuse, to–– (a) fail to comply with any requirement of the Building Regulations, or of an enforcement notice; or (b) wilfully obstructs a Building Inspector in the performance of any of his or her functions under this Ordinance or the Building Regulations. Penalty: A fine, or imprisonment for 5 years, or both. _____________________________ 5 BUILDING CONTROL ORDINANCE, 2013 BUILDING REGULATIONS, 2019 (Section 2) TABLE OF CONTENTS 1. Citation and commencement 2. Interpretation 3. Application 4. Requirement to give notice and make application 5. Fees 6. Appeals 7. Deemed-to-satisfy provisions 8. Powers of entry 9. Testing of drainage installations 10. Material sampling & testing and adequacy of materials & workmanship 11. Stage notices to be given 12. Certificate of occupancy 13. Dangerous structures emergency measures 14. Exemption of certain types of buildings 15. Application to work done by or on behalf of the Crown 16. Amendment of legislation Schedule 1: Form Schedule 2: Fees Schedule 3: Technical Specifications Citation and commencement 1. These Regulations may be cited as the Building Control Regulations, 2019, and come into force on 16th August 2019. Interpretation 2. In these Regulations— “access and facilities for persons with disabilities” means— (a) access and facilities for people who have long-term physical, mental, intellectual or sensory impairments which will allow them to fully and effectively participate in society on an equal basis with others; “Appeals Tribunal” means the Land Development Appeals Tribunal established under section 52 of the Land Planning and Development Control Ordinance 2013; “applicant” means the person giving notice of intention to carry out building work and making application for approval under Regulation 4; “As-built plans” means drawings showing all changes made through-out the construction process and show the exact dimensions, geometry and locations of all elements of the work completed; 6 “Authority” means the Land Development Control Authority established under section 3 of the Land Planning and Development Control Ordinance 2013; “change of use” means there is a change in the purpose, for which a building or part of a building is used, being a change from any Use Class specified in Schedule 1 to the Land Planning and Development Control General Regulations 2013, to any other Use Class so specified or from a use not included in any Use Class to any use specified in a Use Class; “commercial premises” includes any building to which the public has access and all places of employment; “competent person” means a person having sufficient certified training and experience or knowledge and other qualities that allows them to assist others properly in relation to the specific task; “development” has the meaning given to it by section 2(2)(a)(i) of the Land Planning and Development Control Ordinance 2013, and includes change of use; “development permission” has the same meaning given to it under the Land Planning and Development Control Ordinance 2013; “dwelling” is a single dwelling, having any number of storeys; “flat” means a unit of residential accommodation, including holiday accommodation, that is separated horizontally from other accommodation or is separated from other uses within the same building; “habitable” means a safe living environment in compliance with these Regulations; “habitable room” includes a living room, sitting room, dining room, bedroom, study and any other room which might reasonably be used as a bedroom; and any such room which is combined with a kitchen must, for the purposes of Regulation B.5 in Schedule 3, be construed as a kitchen for the purposes of ventilation but as a habitable room for the purposes of providing natural daylight; “President of the Tribunal” has the meaning given to it under the Land Planning and Development Control Ordinance 2013; “the Ordinance” means the Building Control Ordinance 2013, except where otherwise stated. Application 3. (1) These Regulations apply to— (a) all new applications made for construction, except as provided in Regulations 14(1) (exemptions) and 14(2) (partial exemptions); and (b) all new applications made for change of use of buildings, except as provided in Regulations 14(1) (exemptions) and 14(2) (partial exemptions). (2) All building work— (a) up to 3 storeys must comply with the methods and standards of construction of buildings and structures and systems associated with buildings, as set out in Schedule 3; (b) all other buildings or structures must be designed and constructed in accordance with BS EN 1990:2002 Euro codes. Requirement to give notice and make application 4. (1) Notice: A person who intends to carry out building work to which these Regulations are applicable, may not do so without first having submitted to a Building Inspector, in Form A set out in Schedule 1, notice of such intention and application for approval of the plans. 7 (2) Plans: The notice and application referred to in sub-Regulation (1), must be accompanied by plans, in duplicate, showing the full extent of the development intended to be carried out, together with such other details and written particulars necessary to demonstrate compliance with these Regulations. Plans must be submitted at recognised scales and with sufficient detail to make clear the relevant elements of the development. Site plans must include an accurate representation of boundaries and adjoining structures and must include a north point. A Building Inspector may request additional plans and such other information as considered necessary to assess whether the development complies with these Regulations and may not approve the application until such additional plans and other information have been received from the applicant. (3) Registration of submitted application: When a Building Inspector has received all such plans and other information as considered reasonably necessary to assess the proposed building work against these Regulations, together with the fee referred to in Regulation 5, the application must be registered and a Building Inspector must— (a) immediately inform the applicant in writing that the application has been registered; and (b) Consult the Chief Planning Officer, to ensure that the plans comply fully with any Development Permission granted or deemed to have been granted, in respect of the same development, under the Land Planning and Development Control Ordinance 2013. (4) Approval or rejection: Plans that demonstrate compliance with these Regulations must be approved by a Building Inspector and plans that show non-compliance with these Regulations must, except as provided in sub-Regulation (6), be rejected. (5) Completion in accordance with plans: The applicant must ensure that the development is carried out and completed in accordance with the approved plans or such revised plans as a Building Inspector may subsequently approve. All such plans must also comply fully with any development permission granted or deemed to have been granted, in respect of the same development, under the Land Planning and Development Control Ordinance 2013. In the event that ground conditions become apparent in the course of the building work, which could not reasonably have been foreseen, a Building Inspector may approve departures from the approved plans provided that the work still complies with these Regulations and any departures are approved in writing. (6) Conditional Approval And Revised Plans: If in the opinion of a Building Inspector, the failure of plans to show compliance with these Regulations can be corrected by imposition of conditions or submission of revised plans, whilst still complying fully with any development permission granted or deemed to have been granted, in respect of the same development, under the Land Planning and Development Control Ordinance 2013, approval may be given subject to such conditions or in respect of revised plans and the development must be completed in accordance with the conditions and/or revised plans, as the case may be. If, in the opinion of a Building Inspector, further conditions are required throughout the development process to maintain compliance with these Regulations, the Building Inspector must inform the applicant in writing of additional conditions imposed. (7) Notice of approval or rejection: A Building Inspector must give notice in writing of the decision to approve or reject plans within 28 days from the date of registration of the application, or such longer period agreed in writing between the applicant and a Building 8 Inspector where further information is required to assess the design and construction details. Failure to give notice of the decision within this time will result in the plans being deemed approved. (8) Stage inspection notices: When giving notice of approval of plans to the applicant, a Building Inspector must also issue to the applicant any stage inspection notices. Stage inspection notices must be completed by the applicant at the stages of completion referred to in Regulation 11. (9) Certification of satisfactory completion: Upon final inspection by a Building Inspector following submission under Regulation 11(2)(j) of the stage notice of completion, a Building Inspector must immediately, if satisfied that the development complies with these Regulations and is fit for use, issue a certificate to that effect. Other than as provided in sub- Regulation (10), the development may not be brought into use unless such certificate has been issued. (10) Partial completion and use: If, in the opinion of a Building Inspector, part of the development is fit for use without other parts, or elements of that part, having been completed it may, at their reasonable discretion, inform the applicant in writing that the relevant part may be brought in to use subject to the remaining parts or elements being completed within an agreed time-frame specified in the partial completion letter. Sub-Regulation (9) then applies to the remaining parts or elements until final inspection. (11) As-built plans: (a) The Building Inspector has the power to request that As-built plans are submitted by the applicant in certain cases under this sub-Regulation. It remains under the discretion of the Building Inspector to request and to approve such As-Built plans. The premises must not be brought into use if As-built plans are requested and have not been approved. (b) In the case of buildings for any purpose to which the public may have access, in addition to the plans required to be submitted under sub-Regulation (1), a Building Inspector may request upon practical completion of the development plans showing the development as completed. Such plans must be marked “as-built” and must be approved or rejected by a Building Inspector in the like manner to the plans submitted under sub-Regulation (1) within the time frame specified by the Building Inspector. (c) Where the Building Inspector has requested As-built plans and the applicant has not submitted them, the premises may not be brought in to use until those plans have been submitted to the Building Inspector and approved. (d) the Building Inspector may, at his discretion, reject the As-built plans. In the event that as-built plans are rejected, any element of the work not in compliance with these Regulations must be brought in to compliance. Fees 5. (1) The fees set out in Schedule 2 are payable in respect of the matters set out therein. (2) The application fee must be submitted with the notice and application referred to in Regulation 4(1) and the application may not be registered until such fee has been paid. 9 Appeals 6. (1) A person aggrieved by a decision of a Building Inspector to reject the plans, or of deemed rejection, or to the attachment of any condition may, within 28 days of the date referred to in Regulation 4(7), appeal to the Appeals Tribunal. (2) A person aggrieved by a decision of the Chief Building Inspector to serve an enforcement notice under section 4 of the Ordinance, may within 14 days of the date of being served with the notice, appeal to the Appeals Tribunal. (3) The Appeals Tribunal must, within 60 days of receipt of the appeal, give a decision whether the appeal is upheld or dismissed and in default of a decision within 60 days the appeal is deemed to be upheld. (4) In determining any appeal submitted under the Ordinance and these Regulations, the Appeals Tribunal must proceed in the like manner to determine an appeal submitted under the Land Planning and Development Control Ordinance, 2013, so far as applicable to the substance of the appeal and otherwise as may be decided by the President of the Tribunal. Deemed-to-satisfy provision 7. Where any provision in these Regulations, called a deemed-to-satisfy provision, states that the use of a particular material, method of construction or specification is deemed to satisfy the requirements of a Regulation, that provision must not be construed so as to require any person necessarily to use such material, method of construction or specification. Powers of entry 8. A Building Inspector may (at any reasonable time) enter on any land or in any building for the purpose of administering and enforcing these Regulations, subject to sections 3(3), 3(4) and 3(5) of the Ordinance. Testing of drainage installations 9. A Building Inspector may require tests to be conducted of any drainage system that may be necessary to establish compliance with Part H of Schedule 3. Material sampling and testing and adequacy of materials and workmanship 10. (1) A Building Inspector may require such samples of material used, or proposed to be used in the work, and have them subjected to testing as necessary to establish that its properties and use will comply with these Regulations. (2) Materials used in the development must be fit for their purpose in the conditions in which they are to be used, adequately prepared, applied and fixed so as to perform the functions for which they were designed and made. In case of doubt, compliance with a current British Standard or British Standard Code of Practice prescribing the quality of materials or standards of workmanship applicable to the case, or any other internationally recognised standard are deemed to satisfy this requirement. 10 (3) Nothing in this Regulation prohibits the use of locally sourced materials, including pozzolanic earths in concrete, mortars, renders and plasters, gypsum based materials, or components or coverings based on locally excavated or grown materials that are proved by experience or experiment to be fit for their purpose. Stage notices to be given 11. (1) The applicant must ensure that any person who carries out building work to which these Regulations apply, gives notice to a Building Inspector by returning the stage notices at the stages required by sub-Regulation (2) and may not proceed beyond that stage or cover up work until it has been inspected and approved by a Building Inspector or 48 hours from the date of receipt by a Building Inspector, of the stage notice, excluding weekends and public holidays, whichever is sooner. In the event that the work is inspected and not approved, no further work may be done or covered up until it has been corrected and approved, in default of which the Chief Building Inspector may serve an enforcement notice under section 4 of the Ordinance. (2) The Stages are: (a) Site Preparation: boundary pegs installed, vegetation and vegetable top soil stripped, extent of proposed site excavations and access marked out. (b) Site Excavation: Once the site has been excavated to the approved plans. (c) Building Set Out: foundation trenches excavated and foundation reinforcement in place. (d) Slab Preparation: Foundation concrete laid, hard-core, blinding and under-floor damp-proof membrane in place but concrete slab not poured. (e) Damp Proof Course (“DPC”): Floor slab poured and damp proof courses under walls in place. (f) Lintels: Shutter boards and reinforcement in place for in-situ concrete lintels and beams but concrete not poured. (g) Roof: Walls built, roof structure in place, fixed and covered but roof structure not concealed. (h) Drains laid: Ready for testing but not backfilled, inspection chambers and any septic tank constructed but not covered nor backfilled. (i) Soak away: Excavated but not backfilled. (j) Completion of work. (3) Any element which has been structurally designed with accompanying calculations are subject to additional stage inspections, such additional inspections to be listed on the notice under Regulation 4(8) of approval of the plans. (4) In the case of buildings to which the public may have access, a Building Inspector may require additional stage inspections, such additional inspections to be listed on the notice under Regulation 4(8) of approval of the plans. (5) Failure to give notice of any stage inspection will render the person liable for exposing or opening up the work and carrying out any remedial works required at their own expense in order that compliance can be ascertained. 11 Certificate of occupancy 12. (1) Any habitable developments to which these Regulations apply require a certificate of occupancy before the development is brought into use. (2) The minimum requirements are— (a) electrical certification from the relevant utilities service provider; (b) potable water services; (c) cooking & utensil washing facilities; (d) sufficient sanitary convenience facilities; (e) all floors sealed; (f) minimum one coat of paint/cladding on internal walls; (g) all exterior walls weatherproofed; (h) roof completed. Dangerous structures emergency measures 13. (1) If it appears to the Chief Building Inspector at any time that a structure is in a dangerous condition, emergency measures may be taken to remove the danger. (2) Before exercising the power set out in sub-Regulation (1), the Chief Building Inspector must make such attempts as reasonably possible to notify the owner of the proposed measures and may accept a proposal from the owner to undertake to remove the danger in a defined timescale. (3) Where the Chief Building Inspector finds it necessary to arrange for the carrying out of emergency work, the owner of the structure is liable for the full cost of such work. Exemption of certain types of buildings 14. (1) The following types of building are exempt from these Regulations: (a) a temporary building that is not intended to remain for more than 6 months and does not so remain for more than 6 months; (b) a building which is an animal shelter or agricultural storage building, greenhouse or polytunnel and used solely for that purpose; (c) a building which is not normally entered except for the purpose of maintenance of that building or of equipment associated with it; (d) a detached single storey building with a floor area not exceeding 28m² with no sleeping accommodation, provided it is sited at least 2m from any other building or the boundary of its curtilage; (e) a single storey extension with a floor area not exceeding 28m² of the nature of a porch, verandah, covered way or car port, provided that it is sufficiently open not to restrict day lighting or natural ventilation to habitable rooms nor obstruct a fire exit and provided it is sited at least 2m from the boundary of the curtilage of the building to which it is attached. (2) The following partial exemptions apply in respect of historic buildings: (a) except in respect of structural stability and fire safety, historic buildings are exempt from these Regulations for— (i) changes of use; and 12 (ii) extensions, to such extent that exemption is reasonably necessary to retain their architectural and historic value or their contribution to the character of a Historic Conservation Area; (b) for the purposes of this Regulation, historic buildings are Listed Buildings and associated structures and vernacular buildings of traditional form and construction that are relevant for the purposes of sections 39 to 41 of the Land Planning and Development Control Ordinance, 2013. Application to work done by or on behalf of the Crown 15. These Regulations apply to development by, or on behalf of, St Helena Government except development for the purpose of alleviating an imminent or existing public emergency. Any such development must be brought in to compliance with these Regulations as soon as practicable after the end of such public emergency or the development removed and the land (and any building affected by the development) reinstated to its previous condition. Amendment of legislation 16. Paragraph 1 of Schedule 2 to the Land Planning and Development Control (Forms and Fees) Regulations, 2013, is amended by deleting sub-paragraph 3. _______________________ 13 14 15 SCHEDULE 2 FEES 1. Subject to paragraphs 2, 3 and 4, the fees payable under these Regulations are as follows: New Floor Area Created Fee New Dwellings Up to 90m² £125.00 90m² up to 120m² £185.00 120m² up to 200m² £300.00 £300.00 plus £50.00 for every Exceeding 200m² 45m² over 200m² Domestic extensions, domestic alterations and ancillary buildings Up to 12m² £75.00 12m² up to 30m² £120.00 30m² up to 90m² £160.00 Exceeding 90m² £215.00 Non-domestic Developments Up to 90m² £125.00 90m² up to 120m² £185.00 120m² up to 250m² £300.00 250m² up to 500m² £600.00 £600.00 plus £50.00 for every Exceeding 500m² 100m² over 500m² Appeals Up to 120m² £180.00 Exceeding 120m² Twice the application fee but limited to £1200.00 New Roof Structure £65.00 Application for Exemption £10.00 2. If the development application includes more than one dwelling of identical design, the building regulations fee payable in respect of the second dwelling must be reduced by one-third and on the third and subsequent identical dwellings by one half. 3. The fees in the table in paragraph 1 must be reduced by 50 per cent in the case of an application for development by— (a) a charitable organization registered under the Charities Ordinance, 2005, for any charitable purpose carried on by such organization as referred to in such Ordinance; or (b) a community association registered under the Community Centres Ordinance 1988, for purposes of providing any community facilities. 16 4. No fees are payable in respect of development undertaken solely to facilitate easier access by disabled persons to any buildings or land, or to the use of such buildings or land. 5. Any fee paid by a person in respect of the lodging of a notice of appeal, must be refunded if the appeal is upheld or the original decision against which the appeal was noted is varied on appeal. _____________________ 17 SCHEDULE 3 TECHNICAL REGULATIONS PART A: Structural Stability A.1. Structural Design A.2. Foundations A.3. Substructure And Retaining Walls A.4. Walls Above Ground A.5. Support Over Openings A.6. Timber As A Structural Member PART B: Moisture, Contaminants, Insects, Ventilation & Daylight B.1. Clearance Of Top-Soil And Site Contaminants B.2. Drainage Of Subsoil And Re-Routing Watercourses B.3. Resistance To Moisture For Floors, Walls And Roofs B.4. Resistance To Insect Damage Of Floors, Walls And Roofs B.5. Room Sizes, Day lighting And Ventilation In Dwellings PART C: Fire Safety C.1. Means Of Warning And Escape (Dwellings) C.2. Fire Spread (Structure)(Dwellings) C.3. Requirement For Fire Safety For Flats C.4. Fire Spread (Structure)(Flats) C.5. Fire Spread (Surfaces)(Flats) C.6. Fire Fighting (Surfaces)(Flats) C.7. Means Of Warning & Escape (Commercial & Places Of Employment) C.8. Fire Spread (Structure)(Commercial & Places Of Employment) C.9. Fire Spread (Surfaces)(Commercial & Places Of Employment) C.10. Fire Fighting Equipment (Commercial & Places Of Employment) C.11. Fire Safety: Others PART D: Staircases, Ramps and Protection From Falling D.1. Private Staircases D.2. Common Staircases D.3. Ramps D.4. Guarding Of Balconies, Landings And Flat Roofs PART E: Glass Safety PART F: Access And Facilities For Persons With Disabilities PART G: Resistance To The Passage Of Sound PART H: Rainwater, Foul And Waste Water Drainage & Disposal H.1. Rainwater Drainage, Storage And Disposal H.2. Foul And Waste Water Drainage And Disposal H.3. Septic Tanks, Soak Away And Secondary Treatment Systems PART I: Sanitation And Hot Water Safety PART J: Heat Producing Appliances And Gas Storage J.1. Safety J.2. Air Supply To Appliances J.3. Flue Pipes And Chimneys J.4. Gas Storage PART K: Electrical Safety 18 TABLES Table 1: Width Of Strip Foundation Table 2: Minimum Thickness Of Wall Table 3: In-Situ Reinforced Concrete Lintels (Only Supporting Roof) Table 4: In-Situ Reinforced Concrete Lintels (Supporting One Additional Storey) Table 5: Floor Joists In Domestic Dwellings Table 6: Floor Joists In Non-Domestic Dwellings Table 7: Rafters Supporting Slate Or Tiles Table 8: Purlins Table 9: Staircases Table 10: Glazing Maximum Pane Area Table 11: Septic Tanks Table 12: Minimum Provisions Of Toilets For Catering Facilities (Non-Liquor) Table 13: Minimum Provisions Of Toilets For Public Entertainment (Non-Liquor) Table 14: Minimum Provisions Of Toilets For Public Houses & Bars Table 15: Minimum Provisions Of Toilets For Places Of Work Table 16: Minimum Provisions Of Toilets For Hotels Table 17: Minimum Provisions Of Toilets For Nursing Homes Table 18: Minimum Provisions Of Toilets For Outdoor Music Events PART A: STRUCTURAL STABILITY A.1. STRUCTURAL DESIGN Structural design and loading shall be in accordance with BS EN 1990:2002 Eurocodes or as per deemed-to-satisfy provisions contained within this document: (1) BS EN 1990:2002 Eurocodes 1 - General Basis of Design; (2) BS EN 1990:2002 Eurocodes 2 - Concrete; (3) BS EN 1990:2002 Eurocodes 3 – Steel; (4) BS EN 1990:2002 Eurocodes 4 - Composite Steel and Concrete; (5) BS EN 1990:2002 Eurocodes 5 – Timber; (6) BS EN 1990:2002 Eurocodes 6 – Masonry; and (7) BS EN 1990:2002 Eurocodes 7 - Geotechnical Work and Foundations. A.2. FOUNDATIONS (1) The foundations of a building shall safely sustain and transmit to the ground the combined dead load, imposed load and wind load of the structure without permitting deflection or deformation of any part of the building, or such movement of the ground as will impair the stability of any other building. 19 (2) Foundations shall extend down to a depth that will safeguard the structure from landslip on sloping sites and shall accommodate swelling or shrinkage of the ground, in so far as the risk can be reasonably foreseen, sufficient to ensure stability of the building. (3) Foundations shall be designed to suit building design and site conditions. Structural calculations shall be provided in support of raft or piled foundation designs and in any case where ground conditions are such that, in the opinion of a Building Inspector, calculations are necessary including as to reinforcement. (4) The following are Deemed-to-Satisfy provisions for Simple Strip Foundations: a) Provide a concrete strip foundation composed of one part cement to three parts stone dust or washed sand to three parts coarse aggregate by volume, with an approximate water to cement ratio of 0.5. The thickness to be a minimum of 225mm and its width dependent upon the loadbearing characteristic of the soil and in any event not less than as shown in Table 1. There is to be no made ground or wide variation in the type of subsoil. Any step in the foundation must extend a lap equal to the thickness of the concrete or 300mm whichever is the greater and the maximum height of step must not exceed the thickness of concrete. (5) The following are Deemed-to-Satisfy provisions for Simple Trench-fill Foundations: a) Provide a fully filled trench of concrete composed of one part cement to three parts stone dust or washed sand to four parts coarse aggregate by volume, with an approximate water to cement ratio of 0.5. The trench to be excavated down to firm ground and in any event not less than 600mm, its sides accurately cut vertical and its width not less than 150mm projection each side of the wall for single storey or 225mm in the case of two storey buildings and three storey buildings. TABLE 1 WIDTH OF STRIP FOUNDATIONS Type of Soil in Base Minimum Projection each Side of Trench of the Wall (P) Test Excavation Feasible Using (Determined By Single Two Three Building Inspector) Storey Storey Storey Rock Requires at least a pneumatic or other (Assumed BP of mechanically operated pick for 150mm 225mm 225mm minimum 2000kn/m) excavation. Gravel or hard clay Requires Hand pick or other mechanically (Assumed BP of 150mm 225mm 325mm operated spade for excavation. minimum 600kn/m) Firm Clay Can be easily moulded by substantial (Assumed BP of pressure with the fingers and can be 150mm 275mm N/A minimum 150kn/m) excavated with a spade. Clay soft or loose (Assumed BP of Can be excavated with spade. 250mm N/A N/A minimum 75kn/m) 20 Diagram A(1) & A(2) Foundation Details A.3. SUBSTRUCTURE AND RETAINING WALLS (1) The substructure of any structure shall be constructed to transmit the load of the superstructure safely to the foundations. Designs for abnormal structures or abnormal ground conditions, including sites with a gradient steeper than 1 in 4 (14˚), are to be supported by detail drawings showing construction methods and calculations. (2) The following are Deemed-to-Satisfy provisions for Normal Substructure Walls: a) Provide a wall of solid or fully filled hollow concrete blocks, achieving a compressive strength not less than 7.0 N/mm² laid horizontally in cement mortar 1:3 the wall to have a thickness not less than the thickness of the wall it supports. (3) The following are Deemed-to-Satisfy provisions for Propped Retaining Walls Up To 2.5m High And Tied By Reinforcing Bars To Upper And Lower Floor Slabs: a) For buildings founded on rock, gravel hard clay and firm clay as in Table 1 above, provide 16mm starter bars for the wall cast into the foundation and linked into the foundation reinforcement. Provide a wall of hollow concrete blocks 225 thick of compressive strength not less than 7.0 N/mm² in 1:3 cement mortar, in courses laid horizontally with joints staggered in alternate courses and containing 16mm vertical reinforcing bars in every block, linked to the starter bars, extending the full 21 height of the wall and cast minimum 480mm horizontally into the upper slab, the blocks to be fully filled with concrete as work proceeds, the wall protected with a continuous damp proof membrane and drainage as in Deemed to Satisfy to Regulation B.3.(4). A.4. WALLS ABOVE GROUND (1) Walls constructed above ground level shall sustain vertical loading, horizontal wind loading and roof uplift. Masonry walls shall be bonded or securely tied to other elements of a structure in order that they act structurally together. (2) The following are Deemed-to-Satisfy provisions for Concrete Blockwork Walls Above Ground Level: a) Provide concrete blockwork wall to a thickness shown in Table 2 dependent upon the height and length of the wall and with support from return walls, piers or chimneys at each end; b) The compressive strength of blocks to be not less than 7.0N/mm² laid in 1:3 cement mortar; c) The maximum depth of any chase to be formed in the wall is one sixth the wall thickness for horizontal chases and one third the wall thickness for vertical chases, save that no chases shall be formed in separating wall in flats; and d) At the discretion of a Building Inspector following site excavation stage inspection, ground conditions are such that it necessary to include movement joints for the full height and thickness of external walls (including through any external render), with slip ties in alternate course to maintain lateral stability, at maximum 6m centres. Movement joints to be filled with compressible material and sealed externally with polysulphide mastic, the applicant will be informed in writing. Table 2 Length of wall where return walls, piers or chimneys are required. Wall Thickness Max Height (WT) Ground Floor and First Floor Wall Max Span Single Storey of Multi Storey Buildings Wall Max Span 115 5m 5m 3m 150 5m 7m 5m 225 5m 12m 9m G.F 225 5m F.F 115 5m n/a 6m 22 G.F 225 5m F.F 225 12m n/a 9m 23 A.5. SUPPORT OVER OPENINGS (1) Any opening in a structural wall shall have a beam or lintel provided to safely support the structure above the opening at a minimum height of 2100mm. (2) The following (Tables 3 & 4) are Deemed-to-Satisfy Sizes For Lintels In Reinforced Concrete, composed of one part cement to three parts stone dust or washed sand to three parts coarse aggregate by volume, with an approximate water to cement ratio of 0.5. Concrete cover to the bar reinforcement shall be 40mm and not less than 40mm to the ends. Bar shall have a minimum bearing of 100mm and total lintel bearing shall be minimum of 150mm on both ends of the opening. Bar overlaps shall be at least 30 times their diameter. Combined Dead and Imposed load shall not exceed 70Kn/m. O p e n in U p t o U p t o U p t o U p t o U p t o U p t o U p t o U p t o U p t o U p t o U p t o U p t o g W id 0 .7 5 m 1 .4 m 2 .0 m 3 .0 m 0 .7 5 m 1 .4 m 2 .0 m 3 .0 m 0 .7 5 m 1 .4 m 2 .0 m 3 .0 m t h 1 1 1 1 1 1 1 1 2 2 2 2 1 1 1 1 5 5 5 5 2 2 2 2 5 5 5 5 0 0 0 0 5 5 5 5 m m m m m m m m m m m m In L in m m m m m m m m m m m m - S it u R e in t e l S e c t io w id e x 1 5 w id e x 2 2 w id e x 2 2 w id e x 2 2 w id e x 1 5 w id e x 2 2 w id e x 2 2 w id e x 2 2 w id e x 2 2 w id e x 2 2 w id e x 2 2 w id e x 2 2 f o r n S 0 m 5 m 5 m 5 m 0 m 5 m 5 m 5 m 5 m 5 m 5 m 5 m c e iz m m m m m m m m m m m m d e d d d d d d d d d d d d C e e e e e e e e e e e e o e e e e e e e e e e e e n p p p p p p p p p p p p c r e T a t e C o R b le 3 L in t e ls ( o m p r e s s io e in f o r c e m ( H ig h Y ie N / A N / A N / A 2 N o . 8 m N / A N / A 2 N o . 8 m 2 N o . 8 m N / A N / A 2 N o . 8 m 2 N o . 8 m n ly n B e n ld ) m m m m m s a r t u p p 6 6 6 6 6 o R m m m m m r t e m m m m m in g r o o f ) S h e a r in f o r c e m ( L in k s ) N / A N / A N / A @ 1 2 5 m N / A N / A @ 1 2 5 m @ 1 2 5 m N / A N / A @ 1 2 5 m @ 1 2 5 m e m m m m m n t c c c c c / / / / / c c c c c R T e n s io e in f o r c ( H ig h Y 1 N o . 1 1 N o . 1 1 N o . 2 1 N o . 2 1 N o . 1 1 N o . 1 2 N o . 1 2 N o . 2 1 N o . 1 2 N o . 1 2 N o . 1 2 N o . 2 n B a e m e ie ld 0 m m 2 m m 0 m m 0 m m 2 m m 6 m m 2 m m 0 m m 6 m m 2 m m 2 m m 0 m m r n ) t 24 A.6. TIMBER AS A STRUCTURAL MEMBER (1) Timbers used as structural members shall be of sufficient strength to safely support the loads to be carried and shall be resistant to fungal and insect attack. All cut ends shall be re-treated on site before building in and any timbers reduced in thickness after chemical treatment must be re-treated before building in. (2) Floor and roof members shall be securely fixed to walls in both their direction of span and at right angles to the span in order to provide lateral restraint to external walls. Wall plates must be fixed to walls sufficient to resist wind uplift. (3) Ground floors and roof structures shall be cross ventilated in accordance with Regulation B5, for which deemed-to-satisfy provisions are given under that Regulation. (4) The following spans, sizing and spacing shown in Tables 5 to 8 inclusive are deemed-to- satisfy provisions for timbers with a stress grade of C24 or equivalent. (5) The following diagrams A(5) & A(6) are deemed-to-satisfy provisions for the design of roof trusses. O p e n in U p t o U p t o U p t o U p t o U p t o U p t o g W id 0 .7 5 m 1 .4 m 2 .0 m 0 .7 5 m 1 .4 m 2 .0 m t h In 1 1 1 2 2 2 - S it 5 0 m 5 0 m 5 0 m 2 5 m 2 5 m 2 5 m u R L in m m m m m m e t w w w w w w in f o r c e l S e c id e x id e x id e x id e x id e x id e x e d t io 1 5 2 2 2 2 2 2 2 2 2 2 C o n S 0 m 5 m 5 m 5 m 5 m 5 m n iz m m m m m m c r e t e e d e e d e e d e e d e e d e e d e e L p p p p p p in T a b le 4 t e ls ( S u p p o r C o m p r e s s io R e in f o r c e m ( H ig h Y ie 2 N o . 1 2 m 2 N o . 1 6 m 2 N o . 2 0 m 2 N o . 1 2 m 2 N o . 1 6 m 2 N o . 2 0 m t in g o n B a r e n t ld ) m m m m m m n e 8 8 8 8 8 8 a d R m m m m m m d e m m m m m m it io n a l s t o S h e a r in f o r c e m e ( L in k s ) @ 1 2 5 m m @ 1 2 5 m m @ 1 2 5 m m @ 1 2 5 m m @ 1 2 5 m m @ 1 2 5 m m r e n t c c c c c c y / / / / / / ) c c c c c c R T e n s io e in f o r c ( H ig h Y 2 N o . 1 2 N o . 1 2 N o . 2 2 N o . 1 2 N o . 1 2 N o . 2 n B a e m e ie ld 2 m m 6 m m 0 m m 2 m m 6 m m 0 m m r n ) t 25 Diagram A(3) Timber Floor Joist Details Diagram A(4) Timber Floor Joist Notching Details 26 Diagram A(4) Timber Floor Joist Notching Details 27 TABLE 5 - FLOOR JOISTS IN DOMESTIC DWELLINGS Spacing of Joists 400 450 600 (mm) Size of Joists (mm) Maximum Permitted Span of Joists (m) 38 x 150 N/A 3.10 2.70 38 x 225 N/A 4.60 4.00 50 x 100 2.20 2.09 1.82 50 x 125 2.83 2.72 2.47 50 x 150 3.40 3.27 2.97 50 x 175 3.91 3.77 3.43 50 x 200 4.47 4.31 3.92 50 x 225 5.06 4.83 4.42 75 x 125 3.22 3.10 2.83 75 x 150 3.86 3.72 3.39 75 x 175 4.45 4.29 3.91 75 x 200 4.97 4.83 4.47 75 x 225 5.42 5.27 4.93 TABLE 6 - FLOOR JOISTS IN NON-DOMESTIC DWELLINGS Spacing of Joists 400 450 600 (mm) Size of Joists (mm) Maximum Permitted Span of Joists (m) 50 x 100 1.84 1.75 1.54 50 x 125 2.43 2.33 2.06 50 x 150 2.93 2.81 2.55 50 x 175 3.38 3.25 2.94 50 x 200 3.86 3.72 3.37 50 x 225 4.35 4.18 3.80 75 x 125 2.75 2.68 2.43 75 x 150 3.34 3.22 2.93 28 75 x 175 3.86 3.71 3.38 75 x 200 4.41 4.25 3.86 75 x 225 4.88 4.74 4.35 TABLE 7 RAFTERS SUPPORTING SLATE OR TILES Spacing of Rafters 400 450 600 (mm) Size in (mm) Maximum Permitted Span of Rafters (m) 50 x 75 2.73 2.18 1.89 50 x 100 3.06 2.89 2.51 50 x 125 3.80 3.59 3.13 50 x 150 4.53 4.29 3.14 TABLE 8 PURLINS AT 1.2M CENTRES SUPPORTING PROFILED STEEL ROOF SHEETS Size in mm Maximum span of purlin m 50 x 75 1.98 50 x 100 3.04 50 x 114 3.43 50 x 125 3.82 50 x 150 4.50 50 x 175 5.00 50 x 200 5.45 29 Diagram A(5) Timber or Steel Fink Truss Design Diagram A(6) Timber or Steel Howe Truss Design 30 PART B: RESISTANCE TO MOISTURE, CONTAMINANTS AND INSECTS AND ADEQUACY OF VENTILATION AND DAYLIGHT B.1. CLEARANCE OF TOP-SOIL AND SITE CONTAMINATION (1) Unless the building is to be supported entirely clear of the ground, the area to be covered by a structure shall have all vegetable matter removed by stripping all topsoil. If the site contains hazardous or offensive substances, including materials containing asbestos or oil contamination, these shall be registered in accordance with the Environmental Protection Ordinance 2016 and removed and disposed of in accordance with the terms prescribed in that registration. B.2. DRAINAGE OF SUBSOIL AND RE-ROUTING WATERCOURSES (1) Where the dampness of a site so requires, a system of land drains shall be installed to protect the structure from damage and to maintain stability of the site. (2) Where, in the course of excavation, an existing drain is severed or a watercourse discovered, steps shall be taken by the applicant to ensure the continuance of the drain or natural drainage, away from the structure and its foundations. B.3. RESISTANCE TO MOISTURE OF FLOORS, WALLS AND ROOFS The floors, walls and roofs of any structure shall be resistant to the passage of moisture sufficient to ensure that the structure is: i) Internally free from damp; and ii) Not at risk of deterioration through dampness.
Part document.segment-2
Building Control Ordinance, 2013 — segment 2
- document.segment-2 Verify source ↗
Building Control Ordinance, 2013 — segment 2
This provision sets building control standards for moisture resistance, fire safety, stairs and ramps, glazing, accessibility, sound insulation, drainage, sanitation, and room sizes in buildings.
This may be achieved by the following Deemed-to-Satisfy methods for conventional construction or by alternative means that are proven by relevant experience or independent professional certification to be not less effective. The following are Deemed-to-Satisfy provisions in respect of: (1) Moisture Resistance Of Ground Supported Concrete Floors Laid Next To The Ground: a) Provide a concrete floor at least 100mm thick laid on a damp proof membrane of minimum 1000 gauge P.V.C, lapped 300mm at joints, laid on blinded compacted hard-core. b) Mix shall be composed of one part cement to three parts stone dust or washed sand to three parts coarse aggregate by volume, with an approximate water to cement ratio of 0.5. c) The finished floor level to be minimum 150mm above any adjacent external ground. d) Any building which has any adjacent cut-face within 1.8m of the building requires a concrete pavement, 31 e) the pavement to be not less than 50mm thick, 900mm wide and laid with a slope away from the building at not less than 1 in 20 or 3⁰. (2) Moisture Resistance Of Suspended Timber Floors: Provide a timber or composite floor with the underside of its supporting beams or joists at least 450mm clear of the ground, open for cross-ventilation on at least two opposing sides and with: a) An appropriate moisture resistant sealer on the underside of the floor structure; and b) A damp proof and termite resistant material between the timber, at its point of support, and any material which can carry moisture from the ground. (3) Moisture Resistance Of External Walls: a) Buildings in the following Registration Districts: Jamestown, Half Tree Hollow and Rupert’s Valley (see Diagram B(1)): i) Provide a solid concrete blockwork wall not less than 105mm thick with a compressive strength of not less than 3.5 N/mm². ii) Insert a horizontal damp proof course at floor level through the full thickness of the wall and projecting minimum 9mm externally, lapped 300mm at joints. iii) Render the blocks externally with 12mm sand cement render or lime- based render from damp proof course up to eaves level. iv) Below the damp proof course paint any exposed edge of floor slab and the blockwork with bituminous paint down to ground level. The applicant may, at their own discretion and risk, apply a material to form a key and render the bituminous paint provided such render does not bridge the damp proof course. b) Buildings In Locations Other Than As Described In Paragraph (a) Above(see Diagram B(1): i) Provide a solid concrete block wall not less than 150mm thick with a compressive strength of not less than 3.5 N/mm². ii) Insert a horizontal damp proof course at floor level through the full thickness of the wall and projecting minimum 9mm externally, lapped 300mm at joints. iii) Render the blocks externally with 12mm sand cement render or lime-based render from damp proof course up to eaves level. 32 iv) Below the damp proof course paint any exposed edge of floor slab and the blockwork with bituminous paint down to ground level. The applicant may, at their own discretion and risk, apply a material to form a key and render the bituminous paint provided such render does not bridge the damp proof course. c) Provide A Cavity Wall Comprising Of: i) A solid concrete block wall or aerated concrete block wall with damp proof course as in paragraph (3)a)ii) above; and ii) An additional leaf, with a cavity not less than 50mm wide with wall ties at 450 centres; and iii) A continuous stepped tray at window cills, at lintels; and iv) The cavity should be taken down at least 225mm below the damp proof course or a damp proof tray should be provided, to discharge water in the cavity towards the outside leaf; or d) Provide a continuous proprietary external cladding to the whole area of the wall, with appropriate flashings and details all in accordance with the manufacturer’s recommendations, to avoid ingress of rainwater to the blockwork; or e) Insulate and render the wall with a proprietary external insulation and render system applied and detailed in accordance with the manufacturer’s recommendations; or f) Any wall other than described above shall have a minimum u-value of 3.64W/m²K unless manufacturer’s specifications are provided stating that it has been designed as an external wall. 33 Diagram B(1) Moisture Resistance Of External Walls Diagram B(2) Cavity Carried Down & Damp Proof Cavity Tray 34 (4) Moisture Resistance Of Internal Walls that are in contact with the ground (for example retaining walls in split level buildings): a) Provide a continuous damp proof membrane, in sheet form or bituminous paint, on the ground side of the wall with sufficient clear drainage to avoid build-up of water pressure and with sufficient protection to avoid the membrane being pierced by fill material. (5) Moisture Resistance Of Roofs: a) Provide a pre-coated and galvanised profiled metal sheet material, with appropriate flashings and fittings, fixed all in accordance with the manufacturer’s recommendations for the characteristics of the roof and degree of exposure of the site; or b) Provide a breathable sarking membrane and battens, for slates or tiles supported, laid and fixed in accordance with the British Standard applicable to the type of slate or tile and with appropriate flashings at all abutments. (6) Gutters And Downpipes: a) Provide gutters and downpipes and matching fittings installed and fixed in accordance with the manufacturer’s recommendations sufficient to discharge all water from roofs clear of the building. B.4. RESISTANCE TO INSECT DAMAGE OF FLOORS, WALLS AND ROOFS (1) The floors, walls and roofs of any structure shall be resistant to attack by termites and other wood boring insects. This may be achieved by an appropriate combination of: a) Chemical treatment of the ground prior to commencement of building work; and b) Appropriate detailing of the junction of any solid ground floor slab and walls; and c) Incorporation of appropriate details in any wall or post attaching a suspended floor to the ground. B.5. ROOM SIZES, DAYLIGHTING AND VENTILATION IN DWELLINGS (1) In any dwelling or flat: a) At least one bedroom shall have a floor area of not less than 11m²;and b) Every living room shall have a floor area of not less than 11m²; and c) Any room combined with a kitchen shall have a floor area of not less than 11m². Each such room shall have a minimum width of 2.4m and a minimum ceiling height of 2.4m measured to half the internal pitch where there is no horizontal ceiling. (2) There shall be adequate natural daylight and means of ventilation provided to dilute pollutants and to avoid condensation, at a sufficient rate for the health and comfort of people in the building. The means of ventilation may be natural or mechanical or a 35 combination. Nothing in this Regulation shall preclude the use of a whole-house passive- stack ventilation system. a) Deemed-to-satisfy provisions for Natural Daylight And Ventilation Of Habitable Rooms - Provide: i) A window to the external air having a glazed area not less than one eighth of the floor area of the room, at least half of which is open able with the top of that half not less than 1.8m above floor level; Note: a habitable room which is combined with a kitchen shall, for the purposes of this Regulation, be construed as a kitchen (as sub-Regulation B.5(2)(b) below) for the purposes of ventilation but as a habitable room for the purposes of providing natural daylight. b) Deemed-to-Satisfy provisions for Ventilation Of Bathrooms, Toilets And Domestic Kitchens – Provide: i) A window to the external air having a glazed area not less than one tenth of the floor area of the room, at least half of which is open able with the top of that half not less than 1.8m above floor level; ii) Where gas facilities are used, a permanently open ventilation grille to the external air measuring at least 0.050m² (225 x 225mm) not more than 300mm below ceiling level with an insect screen fitted shall be incorporated. Alternatively, but not in kitchens containing a cooking or heat producing appliance that takes combustion air from the room, provide mechanical ventilation extracting at the rate of not less than three air changes of the room per hour and permanently open incoming air at the same rate. c) There shall be adequate means of ventilation in roof spaces, under timber floors and in otherwise unventilated voids to avoid deterioration of the building. d) Deemed-to-Satisfy provision for Ventilation Of Roof Spaces: i) Provide natural cross ventilation in any roof space in the form of air bricks or grilles measuring at least 0.10m² (450mm x 225mm), sufficient to provide insect and bird proof ventilation. e) Deemed-to-Satisfy provision for Ventilation Under Timber Ground Floors: i) Provide natural cross ventilation in the form of air bricks or openings measuring at least 0.10m² (450mm x 225mm), sufficient to provide insect and rodent proof ventilation in at least two opposing walls. 36 PART C: FIRE SAFETY C.1. MEANS OF WARNING AND ESCAPE (DWELLINGS) (1) Any dwelling shall include at least one smoke alarm or heat-rise alarm in each storey, of a type specified by the Chief Fire Officer, located such that it will provide optimum protection to that storey in relation to likely sources of fire, sited not more than 150mm below the relevant ceiling level and not less than 225mm from any wall or beam. Where there are two or more alarms of any type in the dwelling they shall be interlinked so that activation of any one will activate all others. (2) Any habitable room in a dwelling of not more than two storeys, including any basement storey, shall have not less than: a) An external doorway at least 800mm wide, or a doorway or opening at least 800mm wide giving access to a hallway with an external doorway; or b) A doorway leading to a landing and staircase giving access to such a hallway; or c) A doorway leading to a landing and staircase giving access to a room (not including a kitchen) where the point of entry to that room is not more than 3m from an external doorway; or d) A window with an open able area not less than 500mm by 750mm the bottom of which is not more than 1100mm above the floor of that room. Provided that: i) Where a kitchen area is not separated from a hallway, staircase or landing by a door, an additional interlinked heat-rise alarm shall be fitted in the kitchen; and ii) The hallway, staircase and landing shall be not less than 800mm wide at their narrowest point; and iii) Any external doorway as so described shall give access directly to the open air except that a porch of floor area not more than 3m² with its own external doorway may be disregarded. (3) Any habitable room in a dwelling of three or more storeys shall have not less than: a) An external doorway at least 800mm wide, or a doorway at least 800mm wide giving access to a fire protected hallway or landing with an external doorway; or b) A doorway leading to a fire protected landing and staircase giving access to an external doorway or to such a landing or hallway. Provided that: i) “fire protected” for the purposes of this Regulation shall mean that the structure of the floors, walls and ceilings, the staircase itself and all doors opening to them shall be fire resistant for not less than 30 minutes, and the 37 surface linings of walls and ceilings shall not ignite, give off heat or produce toxic fumes within 30 minutes of exposure to fire; and ii) Doors in this context shall include their frames and all door furniture and they shall be fitted with smoke seals; and iii) The hallway, staircase and landing shall be not less than 800mm wide at their narrowest point; and iv) Any external doorway as so described shall give access directly to the open air except that a porch of floor area not more than 3m² with its own external doorway may be disregarded. C.2. FIRE SPREAD (STRUCTURE) (DWELLINGS) (1) Every external wall of a dwelling and every element of structure unless it supports only a roof that: a) Does not form part of an escape route; and b) Is not below any part of the dwelling that contains a window. Shall be so constructed or protected that it has at least 30 minutes fire resistance. (2) In the case of an external wall that is within 2 metres of the boundary of the curtilage of the dwelling, or any wall directly separating the dwelling from another dwelling or a building for any other use, it shall have at least 60 minutes fire resistance. (3) Any wall that separates a dwelling from an attached garage or car port shall have at least 30 minutes fire resistance, including any doorway formed in that wall and the door shall be fitted with a self-closer. The floor of the garage or car port shall either be not less than 100mm below the floor in that doorway or shall slope away from it at least 100mm in the length of the garage or car port. (4) Any roof of a dwelling or of any attached garage or car port shall be covered in non- combustible material or shall be protected on the underside to achieve resistance to fire from any other building or external source for at least 30 minutes. (5) Any concealed void except roof spaces within a dwelling shall be fire stopped at every junction with an element of structure or at any junction with a ceiling or wall and in any event at intervals of not more 5m, sufficient in each case to stop the spread of fire within the void by at least 30 minutes. 38 C.3. REQUIREMENTS FOR FIRE SAFETY OF FLATS: (1) All requirements of Regulation C1 Means of Warning and Escape (Dwellings) above shall apply within any individual flat. In addition, any hallway, landing or staircase giving access to two or more flats or one or more flats in a building also used for any other purpose, shall be formed within a fire protected area that has: a) Fire protection of at least 30 minutes from any flat or any other part of the building, including self-closing fire doors giving access from a flat to the protected area, or 60 minutes in the case of a building of three or more storeys; and b) Except in the case of a single flat, a mains-operated fire alarm system designed and installed in accordance with British Standard BS 5839-1:2002; and c) A minimum width at any point of 900mm or, in the case of a hallway, landing or staircase serving four or more flats 1100mm; and d) At least one permanent opening, or a door opening outwards and able to be opened from inside at all times without the use of a key, leading directly to the open air; and e) Where the protected area includes a staircase, permanent ventilation at the highest point of not less than 0.5m². C.4. FIRE SPREAD (STRUCTURE) (FLATS) (1) All requirements of Regulation C2 Fire Spread (Structure) (Dwellings) above shall apply throughout. In addition, any floor of a flat except a ground floor (but not excluding a suspended timber ground floor) shall be constructed such that it is fire resistant for not less than 60 minutes. C.5. FIRE SPREAD (SURFACES) (FLATS) (1) The surface/lining/finish of any internal wall finish, external wall finish (including external cladding) or ceiling exposed in a flat shall comply with the test criteria for surface spread of flame in British Standard BS 476-7:1997: a) Class 1 for circulation spaces (hallways, landings, lobbies and staircases) and rooms with a floor area over 4m² provided: i) such rooms do not form part of an escape route from any other room; and ii) not more than half the ceiling area is not worse than Class 1. 39 b) not worse than Class 3 for rooms with a floor area of up to 4m². C.6. FIRE FIGHTING EQUIPMENT (FLATS) (1) Fire extinguishers shall be provided in each flat and all communal areas, as specified by the Chief Fire Officer, before the flats are brought into use. C.7. MEANS OF WARNING AND ESCAPE (COMMERCIAL PREMISES AND PLACES OF EMPLOYMENT) (1) In single storey premises up to 200m² there shall be fire exits to the open air, or a place of safety, to which the travel distance from any point is a maximum of 18m, or 45m if: a) There is more than one exit and the angle between exits from any point is not less than 45°; and b) The maximum distance to any one exit is not more than 18m. (2) In single storey premises of more than 200m²; or any premises that are divided into separate compartments for separate uses; and any premises of more than one storey, there shall be fire exits from each compartment and each storey as in sub-Regulation (1) and a mains operated fire alarm system designed and installed in accordance with British Standard BS 5839-1:2002 throughout all compartments and storeys of the premises. (3) For the purposes of sub-Regulation (2) a staircase within a shop that is not enclosed within a protected area may be regarded as a fire exit for the purposes of travel distance in that sub-Regulation provided there is an alternative staircase from the relevant storey that is so enclosed. In this Regulation: a) A fire exit is a door not less than 800mm wide, opening outwards and able to be opened from inside at all times without the use of a key, and b) A place of safety means a fire protected area with at least 60 minutes fire protection and a means of access from it to a fire exit to the open air. The fire resisting area, including all parts leading to the open air, shall have a minimum width of 900mm for premises up to 200m², 1100mm for premises of 200m² to 400m² and at least 1200mm, or as otherwise specified by the Chief Fire Officer, for premises of over 400m² or more than three storeys. (4) A mezzanine floor within the ground storey of commercial premises will not require separate means of escape provided: a) The mezzanine area is not more than two thirds of the area of the ground floor; and b) It has staircases at opposite ends that reach the ground floor each within 6m of a fire exit to a place of safety. 40 C.8. FIRE SPREAD (STRUCTURE) (COMMERCIAL PREMISES AND PLACES OF EMPLOYMENT) (1) Every external wall and every element of structure unless it supports only a roof that: a) Does not form part of an escape route; and b) Is not below any other part of the premises that contains a window, shall be so constructed or protected that it has at least 30 minutes fire resistance. (2) In the case of an external wall that is within 2 metres of the boundary of the premises, or any wall directly separating the premises from another building, the wall shall have at least 60minutes fire resistance. (3) Any internal wall that forms a wall separating compartments or a place of safety in the premises shall have at least 60 minutes fire resistance and shall extend to the full height of the relevant storey including on the topmost floor to the underside of the roof. (4) Any roof of the premises shall be covered in non-combustible material except in respect of translucent roof-lights which may in total not exceed 10% of the roof area. (5) Any concealed void within the premises shall be fire stopped at every junction with an element of structure or at any junction with a ceiling or wall and in any event at intervals of not more 5m, sufficient in each case to stop the spread of fire within the void by at least 30 minutes. (6) Where roof space is formed between any ceiling and roof covering, such space shall be divided by means of non-combustible fire stops with at least 30 minutes fire resistance into areas not more than 250m² and the distance between such stops shall be not more than 20m. (7) Any floor within the premises except a ground floor (but not excepting a suspended timber ground floor) shall be constructed such that it is fire resistant for not less than 60 minutes. (8) In premises of more than 400m² or of more than 3 storeys, the requirements of sub- Regulations C.8 (3) and (6) shall be 90 minutes unless an automatic sprinkler system meeting the recommendations of British Standard BS 5306, Part 2: 1990 is installed throughout the premises. C.9. FIRE SPREAD (SURFACES) (COMMERCIAL PREMISES AND PLACES OF EMPLOYMENT) (1) The surface/lining/finish of any wall or ceiling exposed in commercial premises and places of employment shall comply throughout with Class 1 of the Test Criteria for Surface Spread of Flame in British Standard BS 476-7:1997 except in respect of translucent roof- lights and light fittings, which shall achieve not worse than class 3 and in total may not exceed 20% of the relevant area of roof or ceiling. C.10. FIRE FIGHTING EQUIPMENT (COMMERCIAL PREMISES AND PLACES OF EMPLOYMENT) (1) Fire detection, control and fire fighting equipment and emergency lighting shall be provided in commercial premises and places of employment, as specified by the Chief Fire Officer, before the premises are brought into use or before any change of use is made of the premises. 41 C.11. FIRE SAFETY FOR HOTELS, LODGING HOUSES, NURSING AND CARE HOMES, HOSPITALS AND SCHOOLS (1) In any establishment providing sleeping accommodation and related services and facilities for tourists or providing residential, medical or nursing care or is an educational establishment: a) The higher of the standards of each of the requirements, respectively, of: Part C.3- 6 (fire safety of flats) and Part C7-10 (fire safety of commercial premises and places of employment) shall apply to the premises in respect of: i) Means of warning and escape; ii) Fire spread(structure); iii) Fire spread (surfaces); and iv) Fire fighting equipment, as set out in Regulations C6 and C10. 42 PART D: STAIRCASES, RAMPS AND PROTECTION FROM FALLING Stairs and ramps shall be constructed to ensure the safety to users of a building moving between different levels exceeding 600mm. Stairs, ramps, the edges of floors and balconies and any roof to which people have access, shall be guarded to protect users from the risk of falling. D.1. PRIVATE STAIRCASES (1) A private staircase is a staircase within, or intended to be used by a single dwelling; a) The rise and going of each step shall be identical in every step and the treads shall be horizontal. b) In any tapered tread the minimum going shall be 50mm and the going measured at the mid-point of the nosing of the tread, shall be equal to the going in the remainder of the staircase. c) There shall be a notional landing at the top and bottom of every staircase: i) The notional landing at the top of the staircase and any intermediate landing shall be unobstructed. ii) The notional landing at the bottom of a staircase may be encroached by the swing of a door provided it is at least 400mm from the lowest riser. d) If the staircase has open risers, the treads shall overlap each other by not less than 16mm and the open risers shall be constructed such that a 100mm sphere cannot pass through them. e) At any point where there is a drop of 600mm or more, the staircase and any intermediate landings shall be guarded with handrails either side of the stairs at the height specified in Table 9. f) All private staircases shall be constructed in compliance with Table 9. D.2. COMMON STAIRCASES (1) A common staircase is a staircase serving more than one dwelling or any other purpose; a) The rise and going of each step shall be identical in every step and the treads shall be horizontal; and b) In any tapered tread the minimum going shall be 50mm and the going measured at the mid-point of the nosing of the tread, shall be equal to the going in the remainder of the staircase. c) There shall be a notional landing at the top and bottom of every common staircase. i) The notional landing at the top and bottom of a common staircase and any intermediate landing shall be unobstructed including by the swing of a door. 43 d) If the staircase has open risers, the treads shall overlap each other by not less than 16mm and the open risers shall be constructed such that a 100mm sphere cannot pass through them. e) At any point where there is a drop of 450mm or more, the staircase and any intermediate landings shall be guarded with handrails either side of the stairs at the height specified in Table 9. f) A ‘corduroy’ hazard warning surface shall be provided at the top and bottom landings of a series of flights to give advance warning of a change in level in accordance with Diagram D(5) g) All common staircases shall be constructed in compliance with Table 9 Table 9 Staircases Stairs Private Common Rise (Maximum) 220mm 190mm Going (Minimum) 220mm 240mm 550mm - 550mm - Twice rise plus going 700mm 700mm Maximum Pitch (Nosing to Nosing) 42 degrees 38 degrees Minimum Number of Steps 2 2 Maximum Number of Steps in a 16 16 single straight flight Landings going equal to width equal to width Width of Stairs (Minimum) 800mm 900mm Minimum Head Height 2m 2m (Measured vertically of the pitch line) 840mm - 840mm - Handrail Height 900mm 900mm D.3. RAMPS Private Ramps (1) No ramp shall be steeper than 1 in 10 or 6⁰; and (2) A continuous slope in one direction spanning not more than 10m; and (3) Have a minimum width of 900mm between walls, up-stands or kerbs; and (4) The surface of a ramp, the notional landings and any intermediate landing shall be of a reasonably non-slip material, even when wet; and (5) The headroom over a ramp, the notional landings and any intermediate landing shall be not less than 2m measured vertically off the surface over the full length and width. (6) Landings shall: 44 a) At the foot and head of a ramp, provide landings which are a minimum of 1200mm long and are clear of any door swings or other obstructions; and b) Ensure that any intermediate landing are a minimum of 1200mm long and are clear of any door swings or other obstructions; and c) Make all landings level or with a maximum gradient of 1 in 60 along their length; and d) Changes of direction shall be not less than 45°. (7) The edges of any Ramp shall: a) Be guarded with a handrail at a height between 900mm and 1000mm above the slope of the ramp, constructed such that a 100mm sphere cannot pass through it and in a form that a child cannot readily climb. Common Ramps (1) No ramp shall be steeper than 1 in 10 or 6⁰; and (2) A continuous slope in one direction spanning not more than 10m; and (3) Have a minimum width of 1500mm between walls, up-stands or kerbs; and (4) The surface of a ramp, the notional landings and any intermediate landing shall be of a reasonably non-slip material, even when wet; and (5) The headroom over a ramp, the notional landings and any intermediate landing shall be not less than 2m measured vertically off the surface over the full length and width. (6) Landings shall: a) At the foot and head of a ramp, provide landings which are a minimum of 1200mm long and are clear of any door swings or other obstructions; and b) Ensure that any intermediate landing are a minimum of 1500mm long and are clear of any door swings or other obstructions; or c) If either a wheel-chair user cannot see from one end of the ramp to the other or the ramp has three flights or more then provide intermediate landing a minimum of 1800mm wide and a minimum of 1800mm long as passing places; and d) Make all landings level or with a maximum gradient of 1 in 60 along their length; and e) Changes of direction shall be not less than 90°. (7) The edges of any Ramp shall: a) Be guarded with a handrail at a height between 900mm and 1000mm above the slope of the ramp, constructed such that a 100mm sphere cannot pass through it and in a form that a child cannot readily climb; and 45 b) Have a handrail at the same height on the opposite side for the full length of the ramp and any intermediate landing. D.4. GUARDING OF BALCONIES, LANDINGS AND FLAT ROOFS (1) Where there is a drop of 600mm or more, the edge of any balcony, any landing except an intermediate landing to which Regulation D2(1)(e) applies, and any flat roof to which there is access other than only for maintenance, shall be guarded with a handrail or parapet at a height not less than 1100mm externally and 900mm internally constructed: a) Such that a 100mm sphere cannot pass through it; and b) In a form that a child cannot readily climb; and c) Sufficiently robust to resist a horizontal force of 0.75 KN for each metre of length at a height of 1100mm and a maximum deflection span of 10mm. Diagram D(1) Tapered Tread Details (Private & Common) Diagram D(2) Landings Next to Doors (Private) 46 Diagram D(3) Rise and Going Details (Private & Common) Diagram D(4) Minimum Headroom (Private & Common) 47 48 Diagram D(5) Key dimensions and use of hazard warning surface (Common) 49 PART E: GLASS SAFETY E.1. GLAZING–MATERIALS AND PROTECTION (1) Glazing in critical locations is any location where: a) Glass is used in a door; or b) Is within normal reach from a doorway; or c) Glass is used in or is within normal reach from a staircase or ramp, including in a window, or d) Forms part of guarding of a staircase, ramp, landing, balcony or flat roof; or e) Glass is used in a screen or window at a height of 800mm or less from floor level; f) See Diagram E(1) Below The glass in critical locations shall be laminated or annealed (toughened) safety glass. (2) The thickness of glass required shall comply with Table 10 below. (3) Where the public may have access into or within a building, clear glazing in doors and side-screens in doorways shall be made apparent by: a) Permanent patterns; or b) Lines on the glass not less than 50mm in height at 1.5m above floor level or by equivalent patterns; or c) Rails or grilles sufficient to ensure that a normally sighted person will be aware of the glass. Diagram E(1) Critical glazing locations 50 Table 10 Maximum Pane Area (m²) Type of Glass Nominal Glass Thickness 3mm 4mm 5mm 6mm 8mm 10mm 12mm Monolithic Annealed Glass 0.75 1.5 2.1 3.2 4.6 6.0 6.0 Patterned Annealed and Wired Glass N/A 0.75 1.2 1.9 2.6 3.4 N/A Laminated Annealed Safety Glass N/A N/A N/A 2.9 4.3 5.7 5.7 Toughened Safety Glass N/A 1.9 3.0 4.5 8.0 8.0 8.0 PART F: ACCESS AND FACILITIES FOR PERSONS WITH DISABILITIES F.1. ACCESS AND FACILITIES FOR PERSONS WITH DISABILITIES: (Excepting buildings covered under 14.2) (1) Reasonable provision shall be made in all new, substantially altered or extended buildings to which the public has access or is a place of employment so that: a) Persons with disabilities can reach and use the principal entrances which will have level entry (step-free) access; and b) Corridors shall have a minimum width of 1200mm; and c) Door handles are placed between 800mm & 1100mm; and d) Elements of the building shall not constitute a hazard for persons with disabilities, including impaired sight; and e) Persons with disabilities can use the building’s facilities including by provision of a passenger lift or stair lift where necessary and shall conform to the requirements of the Lift Regulations 1997, SI 1997/831 (Note: These regulations may be met by compliance with, among other things, the relevant British Standards, EN 81 series of standards, in particular BS EN 81-70:2003 Safety rules for the construction and installation of lifts); and f) At least one toilet designed for unisex, wheelchair use is available and accessible; and g) There is suitable accommodation for persons with disabilities in audience or spectator seating; and h) There are suitable aids to communicate for persons with an impairment of sight or hearing in auditoria, meeting rooms and reception areas. Deemed-to-satisfy provisions are: 51 i) The provision of a screen providing information in both an audible and visual format simultaneously. i) There is suitable internal fixtures and fittings designed by a competent person to cater for persons with disabilities; and (2) In the case of alterations to a building that is not a dwelling or a flat and it is impracticable to make adjustments to the level of the existing principal entrance, or any other appropriate existing entrance to permit access for wheelchair users: a) The remaining requirements of this Regulation shall still apply; and b) Portable ramps shall be provided for use at the entrance in compliance Part D.3. (3) Where any building is to be altered or extended, there shall be no obligation to carry out work within the existing building, solely to make it more accessible and usable by persons with disabilities, but: a) Any alteration or extension shall not make the existing building less so; and b) Any extension shall be at least as accessible and usable by persons with disabilities as the building being extended. PART G: RESISTANCE TO THE PASSAGE OF SOUND G.1. SOUND RESISTANCE OF WALLS AND FLOORS OF DWELLINGS, FLATS AND HOTELS OR SIMILAR ESTABLISHMENTS PROVIDING SLEEPING ACCOMMODATION: (1) A wall which separates a dwelling or flat from another dwelling or flat, or a wall which separates a flat from any communal area in the same building, or which separates bedrooms in hotels or similar establishments from each other or any other use within the same building, shall have sufficient resistance to the passage of airborne sound such that normal speech or the sound from a radio or television at normal levels shall not be audible through the wall. Deemed to satisfy provisions for the construction of walls separating dwellings or flats are: a) solid blockwork walls not less than 150mm thick or hollow blockwork walls not less than 225mm thick in either case of 7.0N/mm² blocks with all joints fully filled and plastered on both sides; or b) studwork walls not less than 200mm internal thickness with separate, alternately staggered 100mm x 50mm studs and noggins each supporting one face of the wall (not connected except by the head and sole plates), and mineral wool quilt at least 50mm thick fitted vertically within the full width and height of the wall. One face of the wall finished with 12.5mm plasterboard and the other finished with double 52 12.5mm plasterboard, all plasterboard joints and both faces of the wall fully plaster skimmed(see diagram G(1)). (2) A floor which separates a flat from another flat or which separates bedrooms in hotels or similar establishments from each other or any other use within the same building shall have reasonable resistance to airborne sound, equal to the requirement in sub- Regulation G1 (1), and also resistance to impact sound such that normal footsteps from persons wearing shoes shall not be audible through the floor. This may be achieved through the form and details of construction, including isolation of structural members, or sound-insulated coverings and ceilings, or a combination. Deemed-to-satisfy provisions for the construction of floors separating flats are: a) solid reinforced concrete floors not less than 150mm thick with a soft covering (e.g. carpet or cushioned vinyl) with a separately supported mineral wool quilt 100mm thick and single 12.5mm plasterboard ceiling beneath with joints fully skimmed (see Diagram G(2)), or b) timber floors comprising T&G Timber or Chipboard floor boards with glued joints, laid as a floating floor on two layers of 9mm plasterboard on a resilient layer of 25mm mineral wool or continuous resilient rubber pads on top of each joist, on joists not less than 200mm x 50mm with a separately supported mineral wool quilt 100mm thick and double 12.5mm plasterboard ceiling beneath with joints staggered and fully skimmed (see Diagram G(3)). Note: in each case the structural floor (slab or joists) must be sufficient for its structural purpose but not less in thickness, for sound resistance, than as stated. (3) Sound resistance of any floor or wall not constructed as specified in the Deemed to satisfy provisions above shall have a minimum sound resistance of 45dB Diagram G(1) Minimum sound resistance requirement for wall separating individual dwelling or flat areas. 53 Diagram G(2) Minimum sound resistance requirement for solid reinforced concrete floors. Diagram G(3) Minimum sound resistance requirement for timber floors PART H: RAINWATER, FOUL AND WASTE WATER DRAINAGE AND DISPOSAL H.1. RAINWATER DRAINAGE, STORAGE AND DISPOSAL (1) Any building shall be designed and equipped such that rainwater is discharged clear of the roofs and walls sufficient to avoid dampness in the building. Gutters and rainwater pipes shall be adequately sized, fixed and jointed and shall have sufficient outlets to accommodate the maximum likely flow. (2) Deemed to satisfy provisions for the sizes of rainwater gutters and pipes for a roof pitch of 30° or less and likely to avoid overtopping in a heavy rain event more than once in twelve months are: 54 a) A single roof slope of area measured horizontally up to 37m² may be served by a 100mm half round rainwater gutter and a single 63mm diameter downpipe sited centrally or 29m² if sited at one end. b) A single roof slope of area measured horizontally up to 75m² may be served by a 120mm “deep flow” gutter and a single 75mm diameter downpipe sited centrally or 55m² if sited at one end. c) A single roof slope of area exceeding 75m² may be served by a number of downpipes as so specified by the Building Inspector. (3) Except as provided in Regulation H1 (6), rainwater from roofs or any other surface shall not be discharged to any system of foul drainage, including the soak-away of a septic tank. (4) Roof water from any building of ground floor area up to 100m² shall be discharged to not less than one storage tank of capacity at least 450 litres with a stopcock on the bottom (to enable re-use) and tank overflow directed to a landscaped area or to a storm drain connected to a public storm sewer or to a watercourse or to a soak away but not to any part of a foul drainage system. Roof water from buildings of ground floor area greater than 100m² or made to exceed that floor area by extension, shall be discharged to one storage tank of capacity at least 450 litres for every 100m² or part thereof, with a separate downpipe to each tank. (5) Rainwater drainage systems shall be designed and laid as described in Regulation H2(5) for foul and waste water drainage systems except: a) The minimum gradient may be between 1 in 20 and 1 in 30 for 110mm pipe diameter and between 1 in 30 and 1 in 40 for 150mm pipe diameter; and b) There is no requirement to ventilate the system. (6) On sites within Jamestown Conservation Area (only) where there is no reasonably practicable alternative, rainwater from any surface may be discharged to the foul sewerage system upon written approval from the utilities service provider. H.2. FOUL AND WASTE WATER DRAINAGE AND DISPOSAL (1) Unless authorised in writing by the utilities service provider, no building shall be erected over a public sewer or within 1.5m of a public sewer. (2) Every dwelling and any other building in which sanitary appliances are installed, shall be provided with a foul and waste water drainage system, designed, laid and of such size and gradient that it is self-cleaning. 55 (3) Foul Water (black water) and Waste Water (grey water) shall be discharged to a public foul sewer where it is available. Where connection to a public foul sewer is not reasonably practicable, connection may be made to: a) A private sewer where available; or b) A septic tank and soak-away system; or c) Private treatment system. (4) All Underground Foul and Waste Water Drains shall: a) Be made of durable materials, adequately supported and protected from imposed loads throughout its length; and b) Be not less than 110mm internal diameter; and c) Be laid in a straight line between points of change in direction or gradient; and d) Be laid at a gradient sufficient to prevent accumulation of solid matter, which shall be between 1 in 40 and 1 in 60 for 110mm pipe diameter and between 1in 60 and 1 in 80 for 150mm pipe diameter; and e) Be tested for water tightness after laying, jointing and backfilling sufficient to hold a pressure of a 110mm water gauge for five minutes and subsequently a head loss of not more than 25mm at 100mm water gauge in seven minutes, in default of which the drains shall not be brought into use. (5) All Above Ground Foul and Waste Water Drains shall: a) Be made of durable materials, adequately supported and protected from imposed loads throughout its length; and b) Be laid in a straight line between points of change in direction or gradient; and c) Be visible for inspection. (6) Where any pipe joins another pipe it shall do so obliquely in the direction of flow in that other pipe and at invert level. (7) Where any Foul or Wastewater Drain is laid Under a Building it shall: a) Be laid in a straight line; or b) Be laid in a series of straight lines with double-sealed airtight inspection chambers at junctions; and 56 c) Have at least 100mm of granular or other suitable flexible filling should be provided around the pipe; and d) Be isolated from the effects of settlement of any element of the building. (8) Inspection Chambers shall: a) Be provided at every change of direction; or b) Where another pipe joins the drain; and c) In any event sufficiently frequently that no part of any drain is more than 25m from an inspection chamber; and d) Be of such size and depth as to permit ready access to the pipe for inspection and cleaning; and e) Be in the form of a manhole fitted with suitable access where the depth exceeds 1.2m; and f) Be fitted with a frame and lid sufficiently robust to carry traffic likely to cross it; and g) Contain open channel with smooth benching or be pre-formed to the same effect. (9) Every Foul or Waste Water Drain, including any branch of length 6m or more, shall be vented at its head sufficient to avoid risk that any trap may be drawn. Where the vent is in the form of an open vent pipe it shall extend not less than 900mm above the top of any eaves of the building or any openable window or roof light that is within 3m of the pipe and shall terminate with a bird-proof and rodent- proof cage. (10) Every gully that is connected to a foul or waste water drain shall include a water trap at least 65mm deep. Any sink or other appliance serving a commercial catering kitchen of any description, shall discharge through a gully that includes a grease trap able to be opened and readily cleaned. (11) Any waste appliance connected to a foul or waste water drain or discharging to a gully on a foul drainage system shall do so through a water trap in the waste pipe not less than 50mm deep. Note: A shower or washbasin may discharge through a 32mm diameter P.V.C pipe and a domestic sink or a bath may discharge through a 38mm diameter P.V.C pipe. H.3. SEPTIC TANKS, SOAKAWAY AND SECONDARY TREATMENT SYSTEMS (1) Where connection to a public foul sewer is not reasonably practicable, a foul and waste water drainage system may include a septic tank, provided: 57 a) Utilities service has first confirmed in writing that the site is not within a catchment area for drinking water; and b) The effluent will not contaminate a water course; and c) The design of the soakaway and satisfactory percolation test results in accordance with your Decision Notice, to ensure that effluent from a septic tank can be satisfactorily discharged to the available land through a soak away system. Diagram H(1) Typical Drainage Field 58 Diagram H(2) Typical Drainage Field Cross-Section (2) Any Septic Tank shall be underground on its completion and shall: a) Be of adequate capacity for its purpose; and b) Be constructed such that there is no leakage of contents, nor ingress of subsoil water; and c) Be adequately ventilated with the vent at least 7m from any habitable part of a building, adequately secured on all sides and shall terminate with a bird- proof and rodent-proof cage ; and d) Be designed and constructed with access for sampling and inspection of the contents and to permit emptying and cleaning; and e) Have the inlet and outlet designed and constructed to avoid disturbance of the surface scum or settled contents by incorporating at least two chambers operating in sequence; and f) Be sited within 30m of a vehicular access with a clear route in the open air for an emptying hose; and g) Have a reinforced concrete roof at least 150mm thick and including robust airtight access covers. h) Deemed-to-Satisfy provisions for a Septic Tank to serve a single dwelling are: 59 i) A prefabricated tank certified and installed in accordance with the manufacturers recommendations and complying with British Standard BS EN 12566-1:2010 or SANS 52566-1, ii) with volume not less than that shown in Table 10 in relation to the number of bedrooms in the dwelling; or iii) A Septic Tank of at least the same internal volume built of blockwork generally in accordance with diagram H(3). Table 11 Septic Tank Specifications Capacity (l) Width (m) Depth (m) Length (m) Volume (m³) 2 bedroom 2700 1.2 1.5 1.5 2.7 3 bedroom 3060 1.2 1.5 1.7 3.06 4 bedroom 3420 1.2 1.5 1.9 3.42 5 bedroom 3780 1.2 1.5 2.1 3.78 6 bedroom 4140 1.2 1.5 2.3 4.14 Note: All Dimensions are internal, and below invert level. 60 Ref: Approved Document H, Drainage and Waste Disposal, England & Wales Building Regulations 2010, 2015 edition, Pg31 Septic Tanks, Design and Construction Fig 1.18 Diagram H(3) Double Chamber Septic Tank PART I: SANITATION AND HOT WATER SAFETY I.1. In any building that is or contains a dwelling or a flat, there shall be: (1) Adequate numbers of the appropriate type and size in any building to which these Regulations apply. (2) In any dwelling and in any flat, there shall be: a) At least one water closet with a wash basin with water supply suitable for hand washing shall be provided in rooms containing sanitary conveniences; and b) A sanitary convenience must be provided with ancillary washing facilities, an intervening lobby must separate both from any habitable room unless used solely for sleeping purposes; and c) A bathroom with a fixed bath or shower and a washbasin with a potable cold water supply; and d) A separate kitchen sink suitable for the washing of utensils with a potable cold water supply. I.2. In any building that is a place of employment or to which the public has access, the following provisions in Tables 12 - 18 dependent upon the number and sex of people likely to occupy the building may be made for water closets, wash hand basins and urinals. In addition there shall 61 be a minimum of one baby changing facility in both male and female toilets installed in accordance with the manufacturer’s specifications. Table 12 Restaurants, cafes, canteens, and catering premises (non-liquor licensed premises Appliances For Male Customers For Women Customers WC 1 per 100 up to 400 males plus 1 2 per 50 up to 200 females for every additional 250 (or part plus 1 for every additional of 250) males. 100(or part of 100) females Urinal 1 per 50 males N/A Wash basin 1 per WC and plus 1 per 5 (or part 1 per WC of 5) urinals Cleaner’s sink Adequate provision should be made for cleaning facilities including at least one cleaner’s sink. Note 1: In the absence of more reliable information you should assume that 50% of the customers will be male and 50% female. Note 2: For the provision of toilets for staff, see Table 15. Note 3: For establishments with licensed bars see also Table 14. Table 13 – Buildings used for public entertainment or similar (non-liquor licensed premises) Appliances Males Females WC In single-screen cinemas, In single-screen cinemas, theatres, concert halls and theatres, concert halls and similar premises without similar premises without licensed bars: licensed bars: 1 for up to 250 males plus 1 2 for up to 40 females for every additional 500 (or 3 for 41 to 70 females part of 500) males. 4 for 71 to 100 females Plus 1 for every additional 40 (or part of 40) females Urinal In single-screen cinemas, N/A theatres, concert halls and similar premises without licensed bars: 2 for up to 100 males plus 1 for every additional 80 (or part of 80) males. Wash basins 1 per WC plus 1 per 5 (or 1, plus 1 per 2(or part of 2) part of 5) urinals. WCs. Note 1:
Part document.segment-3
Building Control Ordinance, 2013 — segment 3
- document.segment-3 Verify source ↗
Building Control Ordinance, 2013 — segment 3
This part sets building-safety requirements for sanitation, heating, LPG storage, and electrical installations.
In the absence of more reliable information you should assume that 50% of the audience will be male and 50% female. Note 2: For the provision of toilets for staff, see Table 15. 62 Table 14 – Public Houses and Licensed Bars Appliances For male customers For female customers WC 1 for up to 150 males plus 1 1 for up to 12 females plus 1 to for every additional 150 (or 13 to 30 females plus 1 for part of 150) males. every additional 25 (or part of 25) females. Urinal 2 for up to 75 males plus 1 N/A for every additional 75(or part of 75) males. Wash basins 1 per WC and in addition 1 1 per 2 WCs per 5 (or part of 5) urinals. Cleaners sink Adequate provision should be made for cleaning facilities including at least one cleaners sink. Note 1: For premises which are used for public entertainment or similar, the occupancy for the Licensed areas will be the maximum licensed number (this will be shown on any licence). Table 15 – Places of work Sanitary appliances for any group of staff Number of persons at work Number of WCs Number of Wash Basins 1 to 5 1 1 6 to 25 2 2 26 to 50 3 3 51 to 75 4 4 76 to 100 5 5 Above 100 One additional WC and washing station for every 25 (or part of 25) persons. Alternative scale of provision of sanitary appliances for use by male staff only Number of males at work Number of WCs Number of urinals 1 to 15 1 1 16 to 30 2 1 31 to 45 2 2 46 to 60 3 2 61 to 75 3 3 76 to 90 4 3 90 to 100 4 4 63 Above 100 One additional WC for every 50 (or part of 50) males plus at least one additional urinal for every one extra WC. Table 16– Hotels Type of Appliances/Facilities Number required Remarks accommodation Hotel with en-suite En-Suite 1 per residential Containing: accommodation guest bath/shower, WC bedroom and wash basin Staff bathroom 1 per 9 residential Containing: staff bath/shower, WC and wash basin Bucket/cleaners sink 1 per 30 bedrooms At least 1 on every floor Hotels and guest WC 1 per 9 guests Houses Wash Basin 1 per bedroom Without en-suite Bathroom 1 per 9 guests Containing: Accommodation bath/shower, wash basin and additional WC Table 17– Residential Homes and Nursing Homes for Elderly People Type of Appliances Number Remarks accommodation recommended Residents WC 1 per 4 persons An adequate wash basin is also required Bath 1 per 10 persons Wash basin 1 to each bedsitting room Staff WC At least 1 for staff See Table 15 for places of work Wash Basin 1 In WC compartment Visitors WC 1 Wash basin 1 In WC compartment Kitchen Sink As appropriate Cleaners Room Cleaners sink N/A In each cleaner’s room Other Bed pan As appropriate 64 cleaning/disposal Wash basin 1 In each medical room Table 18- Outdoor music and similar events For events with a gate opening time of 6 For events with a gate opening timeof less hours or more than 6 hours Male Female Male Female 1 WC per 500 males, 1 WC per 100 1 WC per 600 males, 1 WC per 120 Plus 1 urinal per 150 females Plus 1 urinal per 175 females males males 1 wash basin per 5(or part of 5) WCs plus 1 1 wash basin per 5(or part of 5) WCs per 5 (or part of 5) urinals Note 1: For the provisions of toilets for staff, see Table 15. In all cases at least one of the male and female WCs and washbasins shall be designed for use by persons with disabilities, or a separate disabled toilet shall be provided for male and female use complete with washbasin. In either case the layout, dimensions, grab rails etc. shall be in accordance with the provisions of Diagram I(1), I(2) & I(3) I.3. In any building that is a place of employment or the public has access to which includes a changing room or washing facilities such as a bathroom with a fixed bath or shower shall be designed for use by persons with disabilities in accordance with Diagrams I(4), I(5), I(6), I(7) & I(8). I.4. (1) In any building in which hot water is stored in an unvented vessel, effective provision shall be made to ensure that the water is not capable of being heated to a temperature of 100°C or above. (2) The design of any hot water system shall be such that the temperatures of the hot water at the point of delivery to washbasins, baths, showers and bidets shall generally not exceed 44˚C 65 Diagram I(1) Unisex wheelchair-accessible toilet with corner WC. 66 Diagram I(2) Heights and arrangement of fittings in a unisex wheelchair-accessible toilet. 67 Diagram I(3) Height of various fittings in toilet accommodation. Diagram I(4) Self-contained changing room for individual use. 68 Diagram I(5) Self-contained Shower room for individual use. 69 Diagram I(6) Self-contained shower room incorporating a corner WC for individual use. 70 Diagram I(7) Self-contained bathroom incorporating a corner WC for individual use. 71 72 Diagram I(8) Grab rails and fittings associated with a bath. PART J: HEAT PRODUCING APPLIANCES AND GAS STORAGE J.1. SAFETY (1) Any heat producing appliance shall, when installed in a building, operate without danger of igniting the building or producing gases which could be harmful to health. J.2. AIR SUPPLY TO APPLIANCES 73 (1) Any heat-producing appliance other than an electrical appliance shall be so installed that it is provided with an adequate supply of air for combustion and for efficient working of the flue pipe or chimney. a) Unless the appliance is room-sealed, the room in which it is contained shall be provided with at least one permanently open air entry of adequate size directly from the open air; or b) If the room also contains an air extractor fan, the permanently open air entry shall be sufficient to supply the appliance whether or not the extractor fan is in operation; and c) Where gas cooking facilities are used no permanently open air entry or window shall be located adjacent to it. J.3. FLUE PIPES AND CHIMNEYS (1) Any combustion appliance shall be: a) Connected to either a flue pipe or chimney; or b) If the appliance is room-sealed, to a balanced or low level flue and in either case it shall discharge to the open air. (2) Every flue pipe or flue within a chimney shall be provided with means of inspection and cleaning. Every opening for such purpose shall be in the form of a rigid, non-combustible gas-tight cover. No opening shall be made in a flue pipe unless a proprietary unit is provided for inspection and cleaning or as a draught stabiliser or draught director. (3) A flue pipe and any flue in a chimney shall; a) Not serve more than one appliance; and b) Not open into more than one room; and c) In the case of flue blocks, it shall be vertical or no part shall be at an angle less than 60° to the horizontal. (4) Deemed to satisfy provisions for compliance with sub-Regulations (1) and (2) for domestic installations of up to 50 kW rated output and including open fires of any output. a) A flue pipe constructed of cast iron or stainless steel with a diameter not less than that of the appliance outlet, or not less than 225mm x 225mm in the case of an open fire, with a removable cover to a sweeping access point. b) Combustible material not to be closer than 200mm from the flue pipe or 75mm from a chimney that contains a flue with the flue surrounded by at least 100mm thick blockwork. c) The outlet of any flue or flue pipe to be higher than any opening in the building and not less than 900mm above the pitch line of the roof. d) A permanently open supply of air to the room containing the appliance or open fire from external ventilation equivalent to 8000mm² (275mm x 275mm) in the 74 case of dwellings and flats and sufficient to meet the appliance manufacturer’s recommendations in other buildings. J.4. GAS STORAGE (1) Any premises in which liquefied petroleum gas (“LPG”) is sold, a secure facility shall be provided in accordance with requirements of the Chief Fire Officer. (2) In any hotel, lodging house, nursing or care home, hospital or school or any place of employment where LPG is stored in cylinders of capacity greater than 14Kg or premises where LPG cylinders are filled, all gas cylinders shall be contained within a separate structure designed, constructed and ventilated in accordance with requirements of the Chief Fire Officer. (3) In the case of any building containing sleeping accommodation, including any new dwelling or an extension to a dwelling, in which LPG is to be used, the cylinder(s) shall (see diagram J(1)): a) Be fitted with a pressure relief valve; and b) Be stored outside the building; and c) Be at least 1m horizontally and 300mm vertically from any window, door and vent; and d) Be at least 2m from any untrapped drainage gully, or a boundary of the site unless and intervening wall not less than 250mm high is provided; and e) Secured to the building with a chain or similar fixing. Diagram J(1) Location of LPG cylinder(s) 75 PART K: ELECTRICAL SAFETY K.1. Provisions are as follows: (1) Every electrical installation in any new, altered or extended building shall be designed and installed in accordance with the current edition of the BS7671 Requirement for Electrical Installations (“IET Wiring Regulations”). (2) Before any electrical installation or alteration to an existing electrical installation is brought into use it shall be tested by a person qualified and authorised by the utilities service provider, to test and certify the work in accordance with the test procedures and standards recommended in the current edition of the BS7671 IET Wiring Regulations, and so certified by the utilities service provider. (3) An original Electrical Installation Certificate will be issued to the owner to confirm that the electrical work which it relates has been inspected and tested in accordance with the BS7671 IET Wiring Regulations. This certificate should be retained in a safe place and be shown to any person inspecting or undertaking further work on the electrical installation in the future. (4) Any excavation associated with any new, altered or extended building shall not be within three metres of a low-voltage (less than 1000v a.c) electricity conductor pole or a pole stay-anchor, or five metres in the case of a high-voltage (exceeding 1000v a.c) electricity conductor pole or stay-anchor. 76 (5) No part of any new, altered or extended building shall be under any overhead electricity line or electricity cable. (6) Switches and sockets, serving habitable rooms throughout the dwelling shall be between 450mm and 1200mm above floor level. (7) It is recommended that consumer units shall be mounted so that switches are between 1350mm and 1450mm above floor level and mounted in a location which is easily accessed by the user but avoids impact. (8) All wiring to consumer units, meters and ancillary equipment shall be concealed by a non- combustible material. Diagram L(1) Height of switches, socket-outlets and controls ________________________
Provision text is displayed from LexChat’s stored statute record. Use the official source links to verify amendments, commencement, and current legal force.