Iowa Code § 459.202 - Confinement feeding operations structures — separation distances
This provision sets minimum setback distances for confinement feeding operation structures from nearby residences, businesses, institutions, public use areas, and public thoroughfares, with different rules by construction date and animal capacity.
- Jurisdiction
- United States — Iowa
- Instrument
- Code
- Version
- Undated source snapshot
- Language
- en
- Updated
- Official source
- View official record ↗
Statute overview
About this statute
This page preserves the statute’s identified version, provision structure, official source link, and stored legal text for reading and research.
Search within this statute
Search all stored provisions in this version.
Legal text
Provisions of Iowa Code § 459.202 - Confinement feeding operations structures — separation distances
Showing 1 of 1
- § Verify source ↗
Iowa Code § 459.202 - Confinement feeding operations structures — separation distances
This provision sets minimum setback distances for confinement feeding operation structures from nearby residences, businesses, institutions, public use areas, and public thoroughfares, with different rules by construction date and animal capacity.
The following shall apply to confinement feeding operation structures: 1. a. Except as provided in subsection 3 and sections 459.203, 459.205, and 459.206, this subsection applies to confinement feeding operation structures constructed on or after May 31, 1995, but prior to January 1, 1999; and to the expansion of structures constructed prior to January 1, 1999. b. The following table represents the minimum separation distance in feet required between a confinement feeding operation structure and a residence not owned by the owner of the confinement feeding operation, or a commercial enterprise, a bona fide religious institution, or an educational institution: Minimum separation distance in feet for operations having Minimum separation an animal weight Minimum separation distance in feet for capacity of 625,000 distance in feet for operations having or more pounds but operations having an animal weight less than 1,250,000 an animal weight capacity of less than pounds for animals capacity of 1,250,000 625,000 pounds for other than cattle, or more pounds for animals other than or 1,600,000 or more animals other than cattle, or less than pounds but less than cattle, or 4,000,000 1,600,000 pounds for 4,000,000 pounds for or more pounds for Type of structure cattle cattle cattle Anaerobic lagoon 1,250 1,8752,500 Uncovered earthen manure storage basin 1,250 1,8752,500 Uncovered formed manure storage structure 1,000 1,5002,000 Covered earthen manure storage basin 750 1,0001,500 Covered formed manure storage structure 750 1,0001,500 Confinement building 750 1,0001,500 Egg washwater storage structure 750 1,0001,500 2. a. Except as provided in subsection 3 and sections 459.203, 459.205, and 459.206, this subsection applies to confinement feeding operation structures constructed on or after January 1, 1999, but prior to March 1, 2003, and to the expansion of structures constructed on or after January 1, 1999, but prior to March 1, 2003. b. The following table represents the minimum separation distance in feet required between a confinement feeding operation structure and a residence not owned by the owner of the confinement feeding operation, or a commercial enterprise, a bona fide religious institution, or an educational institution: Minimum separation distance in feet for operations having Minimum separation an animal weight Minimum separation distance in feet for capacity of 625,000 distance in feet for operations having or more pounds but operations having an animal weight less than 1,250,000 an animal weight capacity of less than pounds for animals capacity of 1,250,000 625,000 pounds for other than cattle, or more pounds for animals other than or 1,600,000 or more animals other than cattle, or less than pounds but less than cattle, or 4,000,000 1,600,000 pounds for 4,000,000 pounds for or more pounds for Type of structure cattle cattle cattle Anaerobic lagoon 1,250 1,8752,500 Uncovered earthen manure storage basin 1,250 1,8752,500 Uncovered formed manure storage structure 1,250 1,5002,000 Covered earthen manure storage basin 1,000 1,2501,875 Covered formed manure storage structure 1,000 1,2501,875 Confinement building 1,000 1,2501,875 Egg washwater storage structure 750 1,0001,500 3. a. Except as provided in sections 459.203, 459.205, and 459.206, this subsection applies to confinement feeding operation structures constructed on or after May 31, 1995, but prior to March 1, 2003; to the expansion of structures constructed on or after May 31, 1995, but prior to March 1, 2003; and to the expansion of structures constructed prior to May 31, 1995. b. The following table represents the minimum separation distance in feet required between a confinement feeding operation structure and a public use area; or between a confinement feeding operation structure and a residence not owned by the owner of the confinement feeding operation, a commercial enterprise, a bona fide religious institution, or an educational institution, if the residence, commercial enterprise, religious institution, or educational institution is located within the corporate limits of a city: Minimum separation distance in feet for operations having Minimum separation an animal weight Minimum separation distance in feet for capacity of 625,000 distance in feet for operations having or more pounds but operations having an animal weight less than 1,250,000 an animal weight capacity of less than pounds for animals capacity of 1,250,000 625,000 pounds for other than cattle, or more pounds for animals other than or 1,600,000 or more animals other than cattle, or less than pounds but less than cattle, or 4,000,000 1,600,000 pounds for 4,000,000 pounds for or more pounds for Type of structure cattle cattle cattle Confinement feeding operation structure 1,250 1,8752,500 4. a. Except as provided in subsection 5 and sections 459.203, 459.205, and 459.206, this subsection applies to confinement feeding operation structures constructed on or after March 1, 2003, and to the expansion of confinement feeding operation structures constructed on or after March 1, 2003. b. The following table represents the minimum separation distance in feet required between a confinement feeding operation structure and a residence not owned by the owner of the confinement feeding operation, a commercial enterprise, a bona fide religious institution, or an educational institution: For a confinement For a confinement feeding operation For a confinement feeding operation having an animal feeding operation having an animal unit capacity of having an animal unit capacity of 1,000 or more but unit capacity of less than 1,000 less than 3,000 3,000 or more Type of structure animal units animal units animal units Anaerobic lagoon 1,875 2,5003,000 Uncovered earthen manure storage basin 1,875 2,5003,000 Uncovered formed manure storage structure 1,500 2,0002,500 Covered earthen manure storage basin 1,250 1,8752,375 Covered formed manure storage structure 1,250 1,8752,375 Confinement building 1,250 1,8752,375 Egg washwater storage structure 1,000 1,5002,000 5. a. Except as provided in sections 459.203, 459.205, and 459.206, this subsection applies to confinement feeding operation structures constructed on or after March 1, 2003, and to the expansion of confinement feeding operation structures constructed on or after March 1, 2003. b. The following table represents the minimum separation distance in feet required between a confinement feeding operation structure and a public use area; or between a confinement feeding operation structure and a residence not owned by the owner of the confinement feeding operation, a commercial enterprise, a bona fide religious institution, or an educational institution, if the residence, commercial enterprise, religious institution, or educational institution is located within the corporate limits of a city: For a confinement For a confinement feeding operation For a confinement feeding operation having an animal feeding operation having an animal unit capacity of having an animal unit capacity of 1,000 or more but unit capacity of less than 1,000 less than 3,000 3,000 or more Type of structure animal units animal units animal units Confinement feeding operation structure 1,875 2,5003,000 6. Except as provided in section 459.205, a confinement feeding operation structure shall not be constructed or expanded within one hundred feet from a public thoroughfare. 95 Acts, ch 195, §16 CS95, §455B.162 98 Acts, ch 1209, §15 – 17, 53; 99 Acts, ch 114, §58, 59; 2002 Acts, ch 1137, §11 – 17, 67, 68, 71 ; 2002 Acts, 2nd Ex, ch 1003, §260, 262 C2003, §459.202 2013 Acts, ch 30, §104 – 108; 2021 Acts, ch 76, §117, 118 Referred to in §459.203, 459.205, 459.207, 459.303, 459.304, 459.305, 654C.1 For separation distance requirements established between an anaerobic lagoon or earthen waste slurry storage basin constructed or expanded within certain dates prior to May 31, 1995, and a residence not owned by the owner of the feeding operation, see §455B.134 For prohibition against constructing or expanding an earthen storage structure within an agricultural drainage well area, see §460.205
Provision text is displayed from LexChat’s stored statute record. Use the official source links to verify amendments, commencement, and current legal force.
Ask AI about this statute
Iowa Code § 459.202 - Confinement feeding operations structures — separation distances
Sign in to ask AI about this statute
Sign in to start authenticated, citation-grounded statute research.
Sign inLexChat organizes source-backed legal information for research. Verify amendments, commencement, and current legal force with the official publisher before relying on it.