A minimum standard fence for section 6 must include specified wire, posts, droppers, and straining posts, with extra requirements for certain wooden poles.
54.74 kilometres to the Soli Wa Manyika Reserve No. XVII boundary. District D153 From its junction with Road F4 in a southerly direction for 38.64 kilometres to the Soli Wa Manyika Reserve No. XVII boundary. District D162 From its junction with Road F2, 6.118 kilometres south of the Lusaka Municipal Boundary for 10.304 kilometres to its junction with Road D575. District D575 From its junction with Road D162 in an easterly and southerly direction for 33.005 kilometres to the Kafue Township Boundary. District D379 From Monze Township to the Magoye River. (9.66 kilometres.) District D365 From Monze Township to the Keemba Hill turn-off, Road D372. (12.88 kilometres.) By Laws.Africa and contributors. Licensed under CC-BY. Share widely and freely. 13 Fencing Act, 1949 (Chapter 190) Zambia Classification Serial No. Portion of Road affected of Road of Road District D381 From the railway crossing near Tambero Siding to the Magoye River. (6.0375 kilometres.) District D374 From its junction with Road F1 in a westerly direction for a distance of 8.533 kilometres. District D384 From Magoye Siding to the eastern boundary of Farm No. 214a "Dora". (17.71 kilometres.) District D359 From its junction with Road F1 in a southerly direction for 13.041 kilometres to the Tonga (Choma) Reserve No. XXI boundary. District D354 and D355 From its junction with Road F1 in a westerly direction to its junction with Road BR27 and continuing westwards as Road D355 for a total distance of 21.735 kilometres to the Trust Land No. I boundary. District D370 From its junction with Road D368 to a point where it enters Trust Land No. XIII on the boundary of Farm No. 262a R.E. (4.43 kilometres.) [No. 32 of 1950 as amended by G.N. Nos. 87 and 203 of 1961, G.N. Nos. 129 and 333 of 1963, S.I. Nos. 431 and 443 of 1966 and S.I. No. 277 of 1969] Fifth Schedule (Section 6) Minimum standard fence For the purpose of section 6, a minimum standard fence shall consist of— (a) four strands of barbed or plain galvanised iron or steel wire of not less than 427.5 kg breaking strain, the top strand being a minimum of 1220 mm from the ground; (b) poles or standards of wood or iron placed at intervals of not more than 13.725 metres and substantially and well planted with a minimum of 450 mm deep in soil, with droppers placed at regular intervals of not more than 3.66 metres between such poles or standards in such a way that such droppers are at all times well clear of the ground; and (c) substantial straining posts not more than 366 metres apart; with recognised iron frames erected where necessary. Where wooden poles are used— By Laws.Africa and contributors. Licensed under CC-BY. Share widely and freely. 14 Fencing Act, 1949 (Chapter 190) Zambia (a) poles made from trees known as— Afrormosia angolensis (mubanga), Colophospermum mopane (mopani), Baikiaea plurijuga (mukusi), Diospyros mespiliformis (muchenje), Dichrostachys cinerea (katenge), Erythrophleum africanum (kayimbi, kabulwebulwe), Monotes sp. (mutembo), Swartzia madagascariensis (mukuleti), may be used provided that: (i) poles shall be at least 1.524 metres in diameter under bark at the narrowest part; (ii) all bark shall be removed before planting; and (iii) poles shall be notched to the depth of the hard core and the wire of the fence shall be fastened in the notches with wire of at least fourteen gauge or with fencing staples; (b) poles made from trees of the Eucalyptus species may be used, provided that: (i) poles shall be chemically treated so as to be effectively protected against attack by termites, other insects and fungus; (ii) poles shall be at least 75 mm in diameter under bark at the narrowest part; (iii) all bark shall be removed before chemical treatment; (iv) poles shall be notched to such depth as is necessary to secure the wire of the fence adequately and such wire shall be fastened in the notches with wire of at least fourteen gauge or with fencing staples; and (v) the notches shall not enter the wood beyond the depth of penetration of the chemical used in treatment; (c) poles made from trees other than those specified in (a) and (b) above may be used, provided that: (i) poles shall be chemically treated so as to be effectively protected against attack by termites, other insects and fungus; (ii) poles shall be at least 125 mm in diameter under bark at the narrowest part; (iii) all bark shall be removed before chemical treatment; (iv) poles shall be notched to such depth as is necessary to secure the wire of the fence adequately and such wire shall be fastened in the notches with wire of at least fourteen gauge or with fencing staples; and (v) the notches shall not enter the wood beyond the depth of penetration of the chemical used in treatment. [No. 61 of 1963] By Laws.Africa and contributors. Licensed under CC-BY. Share widely and freely. 15