14 Mar 2025
Lim Sze Way ALLIANZ GENERAL INSURANCE COMPANY (MALAYSIA) BERHAD PIHAK KETIGA 1. ) Supreme Power Auto Sdn Bhd 2. ) Lim Chaw Teng 3. ) Lim Teck Boon
- Citation
- WA-22NCC-543-11/2018 (Mahkamah Tinggi)
- Court
- High Court
- Case number
- WA-22NCC-543-11/2018 (Mahkamah Tinggi)
The court held insurers failed to discharge the burden of proving deliberate ignition or breach of the storage warranty. Scientifically, FSM's conclusions were undermined by unreliable GC/MS reporting, lack of comparison/control samples, and failure to exclude alternative sources; full room involvement rendered visual low‑level burn indicators unreliable; Bomba's conclusion of electrical arcing at the distribution board was consistent with observed localized damage. MSIG's liquid volume measurements were methodologically unsound and unverified. Result: fire found accidental and no warranty br…